Operational Test of the Overheat Detection System
TASK 36-22-00-710-802-A
Operational Test of the Overheat Detection System
1. Reason for the Job
To do a continuity test of the overheat detection.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 36-22-00-861-056-A ** ON A/C NOT FOR ALL Subtask 36-22-00-941-056-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-710-052-A ** ON A/C NOT FOR ALL
Subtask 36-22-00-942-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:16:30 UTC
Operational Test of the Overheat Detection System
1. Reason for the Job
To do a continuity test of the overheat detection.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-00-740-802-A | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
Subtask 36-22-00-861-056-A ** ON A/C NOT FOR ALL Subtask 36-22-00-941-056-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On ENG panel 115VU, put a WARNING NOTICE(S) to tell persons not to start engine 1(2).
(3) On the ENG section of the panel 50VU:
4. Procedure(1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On ENG panel 115VU, put a WARNING NOTICE(S) to tell persons not to start engine 1(2).
(3) On the ENG section of the panel 50VU:
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 36-22-00-710-052-A ** ON A/C NOT FOR ALL
A. Operational Test of the Overheat Detection System
(1) Do the BITE Test of the EBAS with printing of the TEST RESULT page. (Ref. AMM TASK 36-11-00-740-802)
(2) Make sure that the TEST RESULT pages do not show these maintenance indications:
5. Close-up(1) Do the BITE Test of the EBAS with printing of the TEST RESULT page. (Ref. AMM TASK 36-11-00-740-802)
(2) Make sure that the TEST RESULT pages do not show these maintenance indications:
| ATA | MESSAGE | CLASS FAULT |
|---|---|---|
| 362216 | CHECK R WING LOOP A | 2 |
| 362216 | CHECK R WING LOOP B | 2 |
| 362216 | CHECK L WING LOOP A | 2 |
| 362216 | CHECK L WING LOOP B | 2 |
| 362215 | CHECK ENG 1 PYLON LOOP | 2 |
| 362215 | CHECK ENG 2 PYLON LOOP | 2 |
| 362217 | CHECK: APU LOOP OR BMC IDENT CKT | 2 |
| 361134 | BMC1 | 2 |
| 361134 | BMC2 | 2 |
| 361134 | BMC1 | 3 |
| 361134 | BMC2 | 3 |
Subtask 36-22-00-942-052-A ** ON A/C NOT FOR ALL
A. Remove the WARNING NOTICE(S).
Subtask 36-22-00-862-056-A ** ON A/C NOT FOR ALL