Removal of the FAV Scoop
TASK 36-11-54-000-806-A
Removal of the FAV Scoop
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-54-861-065-A ** ON A/C NOT FOR ALL
Subtask 36-11-54-020-067-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:13:40 UTC
Removal of the FAV Scoop
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
ALWAYS USE APPLICABLE GLOVES TO TOUCH HOT PARTS. HOT PARTS CAN CAUSE INJURY TO PERSONS.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803000000 | 1 | LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION |
| 98L12003001000 | AR | HARNESS,SAFETY |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 471 | PYLON LEADING EDGE |
| 481 | PYLON LEADING EDGE |
| 191DB | |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL, 451DL, 452AR, 452DR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL, 461DL, 462AR, 462DR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-00-00-481-002-A | Installation of the Wingrip |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 27-00-00-480-002-A | Installation of the Flap/Slat Control-Lever Locking Tool (98D27803000000) |
| TASK 36-11-42-000-802-A | Removal of the Bleed-Air Precooler Exchanger |
| TASK 36-11-44-000-802-A | Removal of the Bleed-Air Precooler-Exchanger Cold-Inlet |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-06-000-801-A | Removal of the Thrust Reverser Hinge Access Panels |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 36-11-54-861-065-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-54-941-067-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(Ref. AMM TASK 71-00-00-860-833).
(4) On access door 191DB, on the HP ground connector:
(a) Put the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION in position on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
(6) Put a WARNING NOTICE(S) on the flap/slat control lever to tell persons not to operate the flap/slat controls.
(7) Put on and attach a 98L12003001000 HARNESS,SAFETY before you start work in the work area (Ref. AMM TASK 12-00-00-481-002).
Subtask 36-11-54-865-081-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
- Make sure that the APU BLEED pushbutton switch is released (ON legend off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(Ref. AMM TASK 71-00-00-860-833).
(4) On access door 191DB, on the HP ground connector:
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
(a) Put the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION in position on the flap/slat control lever (Ref. AMM TASK 27-00-00-480-002).
(6) Put a WARNING NOTICE(S) on the flap/slat control lever to tell persons not to operate the flap/slat controls.
(7) Put on and attach a 98L12003001000 HARNESS,SAFETY before you start work in the work area (Ref. AMM TASK 12-00-00-481-002).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-54-020-066-B ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
D. Prepare for the Removal
(1) Remove the forward thrust-reverser-hinge access-panels (Ref. AMM TASK 78-30-06-000-801):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451DL 452DR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461DL 462DR.
(2) Loosen the bolt (18) of the FAV rod (17), through the forward right hinge-access-panels.
(3) Loosen the bolt (6) of the scoop rod (8), through the forward left hinge-access-panels.
Subtask 36-11-54-010-090-A ** ON A/C NOT FOR ALL (1) Remove the forward thrust-reverser-hinge access-panels (Ref. AMM TASK 78-30-06-000-801):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451DL 452DR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461DL 462DR.
(2) Loosen the bolt (18) of the FAV rod (17), through the forward right hinge-access-panels.
(3) Loosen the bolt (6) of the scoop rod (8), through the forward left hinge-access-panels.
E. Get Access
(1) Remove the access platform(s).
(2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 36-11-54-040-070-A ** ON A/C NOT FOR ALL (1) Remove the access platform(s).
(2) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
F. Deactivation of the Thrust Reverser for Maintenance
Subtask 36-11-54-010-091-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Make sure that you did the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). G. Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(1) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(2) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
(3) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the engine.
4. Procedure(1) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(2) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
(3) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the engine.
Subtask 36-11-54-020-067-B ** ON A/C NOT FOR ALL
A. Prepare for the Removal of the FAV Scoop
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(4) Remove the bolt (6), washers (3), nut (2) and the bushing (5) from the bracket (4).
(7) Remove the bolt (18) from the FAV (1).
Subtask 36-11-54-410-082-A ** ON A/C NOT FOR ALL (1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Remove the bolt (13), washer (14), nut (16) and the bonding strap (15) from the FAV (1). (4) Remove the bolt (6), washers (3), nut (2) and the bushing (5) from the bracket (4).
NOTE: You can get access to the below part of the left side of the thrust reverser to remove the bolt (6), washers (3), nut (2) and the bushing (5) from the bracket (4) more easily.
(5) Disengage the scoop rod (8) from the bracket (4). NOTE: You can get access to the below part of the left side of the thrust reverser to disengage the scoop rod (8) from the bracket (4) more easily.
(6) Remove the bolts (11) and the washers (10) from the scoop (9). (7) Remove the bolt (18) from the FAV (1).
NOTE: The plate (19) stays attached to the FAV (1) with a metal link.
(8) Disengage the FAV actuator rod (20) from the FAV rod (17). B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
Subtask 36-11-54-410-083-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
Subtask 36-11-54-020-068-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
D. Removal of the FAV Scoop
(1) Remove the precooler exchanger (Ref. AMM TASK 36-11-42-000-802).
(2) Remove the bleed-air precooler-exchanger inlet (Ref. AMM TASK 36-11-44-000-802).
(3) Remove the FAV (1) and scoop (9):
(a) Carefully disengage the FAV (1) from the pin holes (21).
(b) Remove the FAV (1) and scoop (9) at the same time through the precooler fairing.
(4) Disassemble the FAV (1) and scoop (9):
(a) Remove the clamp (24) from the FAV (1) and the scoop (9).
(b) Remove and discard the seal (23).
(1) Remove the precooler exchanger (Ref. AMM TASK 36-11-42-000-802).
(2) Remove the bleed-air precooler-exchanger inlet (Ref. AMM TASK 36-11-44-000-802).
(3) Remove the FAV (1) and scoop (9):
(a) Carefully disengage the FAV (1) from the pin holes (21).
(b) Remove the FAV (1) and scoop (9) at the same time through the precooler fairing.
(4) Disassemble the FAV (1) and scoop (9):
(a) Remove the clamp (24) from the FAV (1) and the scoop (9).
(b) Remove and discard the seal (23).
FAV Scoop