W DOC AIRBUS | AMM A320F

Functional Check of the Overpressure Valves with the Bleed Test Set P/N 98L36103002000


TASK 36-11-53-720-001-A-01
Functional Check of the Overpressure Valves with the Bleed Test Set P/N 98L36103002000


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
FIN: 5HA1 ** ON A/C NOT FOR ALL
FIN: 5HA2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 361100-01
FUNCTIONAL CHECK OF OVERPRESSURE VALVE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
1
OHMMETER MULTIRANGE
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 0.75 and 0.65 m.daN (66.37 and 57.52 lbf.in ) T
98L36103002000
1
TEST SET - ENGINE BLEED
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.03PBB1)
Lubricant-Anti Seize High Temp. -
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL, 452AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 36-11-53-861-055-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-53-941-056-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (2) On the AIR COND panel 30VU:
  • Make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on).
  • Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
  • Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
   (3) On the ENG panel 115VU:
  • Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
   (4) On the HP ground connector:
  • Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
   (5) On the ENG section of the maintenance panel 50VU:
  • Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
  • Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 36-11-53-010-060-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-53-040-055-A ** ON A/C NOT FOR ALL
D. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 36-11-53-010-061-A ** ON A/C NOT FOR ALL
E. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-53-010-060-B ** ON A/C NOT FOR ALL
F. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-53-040-055-B ** ON A/C NOT FOR ALL
G. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 36-11-53-010-061-B ** ON A/C NOT FOR ALL
H. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-53-010-060-D ** ON A/C NOT FOR ALL
I. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-53-040-055-D ** ON A/C NOT FOR ALL
J. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Do the deactivation of the thrust-reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 36-11-53-010-061-D ** ON A/C NOT FOR ALL
K. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
   (2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure
Subtask 36-11-53-480-054-A ** ON A/C NOT FOR ALL
A. Connection of the Test Set
   (1) Disconnect the electrical connector from the overpressure valve.
NOTE: Airbus recommends you to do the check of the electrical continuity on the microswitch.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (2) Cut and discard the lockwire.
   (3) Remove the blanking plug from the test port of the overpressure valve.
   (4) Use a small axle to operate the test port inlet-clapper for some cycles to remove the clapper.
NOTE: You can use all the applicable axles when:
  • It is not necessary to apply force to put them into the test port, as the diameter of the test port is lower than 5 MM (0.197 IN.) (to prevent damage to the port) and
  • There is no sharp edge (to prevent damage to the clapper).
   (5) Close the shutoff valve, the purge valve and the pressure regulator valve on the test set.
WARNING: MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT. IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
   (6) Connect an air cylinder to the 98L36103002000 TEST SET - ENGINE BLEED.
CAUTION: BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT. THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
   (7) Connect the 98L36103002000 TEST SET - ENGINE BLEED with the short-bend flexible assembly to the test port of the overpressure valve.
   (8) Do a reset of the digital pressure gage.
   (9) Make sure that the regulator valve of the test set is closed before you pressurize the system.
Subtask 36-11-53-720-063-A ** ON A/C NOT FOR ALL
B. Do this Test
NOTE: The pressure value given in this test is applicable only to P/N 6740B01XXXX. Because the valves are interchangeable, it is necessary to do a check of the valve reference before the test. If the P/N reference is different from P/N 6740B01XXXX, refer to Para. C, D, E, F or G.
ACTION
RESULT
1.Pressurize the test set:
  • If there is a manometer in the air cylinder then the installation of the primary regulator valve is not necessary. Use the air cylinder shut off valve and the manometer to slowly pressurize the test set to 120 psig (8.27 bar rel.).
  • If there is no manometer in the air cylinder then the installation of primary regulator valve is mandatory. In this case the primary regulator valve will limit the pressure in the test set to 217 psig (14.96 bar rel.).

2.When you do the functional test for first time, apply a higher pressure than 110 psi (7.58 bar) to take off the clapper.

3.On the test set:
  • Open the shutoff valve.
  • Use the pressure regulator valve of the test set to slowly pressurize the system to 90 psig (6.21 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully closed when the pressure is more than 55 psig (3.79 bar rel.).
4.On the overpressure valve:
  • do a check of the electrical continuity between pin 2 and pin 3 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 2 and pin 3 of the electrical connector.
NOTE: Electrical continuity between pin 2 and pin 3 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (CLOSED).
NOTE: Read the pressure on the digital pressure gage.
NOTE: Read the pressure on the digital pressure gage.
5.On the test set:
  • Use the pressure regulator valve of the test set to slowly depressurize the system to open the overpressure valve.
On the overpressure valve (5HA):
  • The visual position indicator shows that the overpressure valve is open when the pressure is equal to or more than 34.95 psig (2.41 bar rel.).
NOTE: Read the pressure on the digital pressure gage.
6.On the overpressure valve:
  • do a check of the electrical continuity between pin 1 and pin 2 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 1 and pin 2 of the electrical connector.
NOTE: Electrical continuity between pin 1 and pin 2 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (OPEN).
7.On the test set:
  • Use the pressure regulator valve to decrease the pressure of the system to 0 psig (0.00 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully open.
Subtask 36-11-53-720-064-A ** ON A/C NOT FOR ALL
C. Do this Test
NOTE: The pressure value given in this test is applicable only to P/N 6740B03XXXX. Because the valves are interchangeable, it is necessary to do a check of the valve reference before the test. If the P/N reference is different from P/N 6740B03XXXX, refer to Para. B, D, E, F or G.
ACTION
RESULT
1.Pressurize the test set:
  • If there is a manometer in the air cylinder then the installation of the primary regulator valve is not necessary. Use the air cylinder shut off valve and the manometer to slowly pressurize the test set to 120 psig (8.27 bar rel.).
  • If there is no manometer in the cylinder then the installation of primary regulator valve is mandatory. In this case the primary regulator valve will limit the pressure in the test set to 217 psig (14.96 bar rel.).

2.When you do the functional test for first time, apply a higher pressure than 110 psi (7.58 bar) to take off the clapper.

3.On the test set:
  • Open the shutoff valve.
  • Use the pressure regulator valve of the test set to slowly pressurize the system to 90 psig (6.21 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve starts to close when the pressure is between 79.78 psig (5.50 bar rel.) and 85.57 psig (5.90 bar rel.).
4.On the overpressure valve:
  • do a check of the electrical continuity between pin 2 and pin 3 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 2 and pin 3 of the electrical connector.
NOTE: Electrical continuity between pin 2 and pin 3 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (CLOSED).
NOTE: Read the pressure on the digital pressure gage.
NOTE: Read the pressure on the digital pressure gage.
5.On the test set:
  • Use the pressure regulator valve of the test set to slowly depressurize the system to open the overpressure valve.
On the overpressure valve (5HA):
  • The visual position indicator shows that the overpressure valve is open when the pressure is equal to or more than 34.95 psig (2.41 bar rel.).
NOTE: Read the pressure on the digital pressure gage.
6.On the overpressure valve:
  • do a check of the electrical continuity between pin 1 and pin 2 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 1 and pin 2 of the electrical connector.
NOTE: Electrical continuity between pin 1 and pin 2 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (OPEN).
7.On the test set:
  • Use the pressure regulator valve to decrease the pressure of the system to 0 psig (0.00 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully open.
Subtask 36-11-53-720-065-A ** ON A/C NOT FOR ALL
D. Do this Test
NOTE: The pressure value given in this test is applicable only to P/N 6740B05XXXX. Because the valves are interchangeable, it is necessary to do a check of the valve reference before the test. If the P/N reference is different from P/N 6740B05XXXX, refer to Para. B, C, E, F or G.
ACTION
RESULT
1.Pressurize the test set.
  • If there is a manometer in the air cylinder then the installation of primary regulator valve is not necessary. Use the air cylinder shut off valve and the manometer to slowly pressurize the test set to 120 psig (8.27 bar rel.).
  • If there is no manometer in the air cylinder then the installation of primary regulator valve is mandatory. In this case the primary regulator valve will limit the pressure in the test set to 217 psig (14.96 bar rel.).

2.When you do the functional test for first time, apply a higher pressure than 110 psi (7.58 bar) to take off the clapper.

3.On the test set:
  • Open the shutoff valve.
  • Use the pressure regulator valve of the test set to slowly pressurize the system to 90 psig (6.21 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully closed when the pressure is between 81 psig (5.58 bar rel.) and 85 psig (5.86 bar rel.).
4.On the overpressure valve:
  • do a check of the electrical continuity between pin 2 and pin 3 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 2 and pin 3 of the electrical connector.
NOTE: Electrical continuity between pin 2 and pin 3 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (CLOSED).
NOTE: Read the pressure on the digital pressure gage.
NOTE: Read the pressure on the digital pressure gage.
5.On the test set:
  • Use the pressure regulator valve of the test set to slowly depressurize the system to open the overpressure valve.
On the overpressure valve (5HA):
  • The visual position indicator shows that the overpressure valve is open when the pressure is more than 50 psig (3.45 bar rel.).
NOTE: Read the pressure on the digital pressure gage.
6.On the overpressure valve:
  • do a check of the electrical continuity between pin 1 and pin 2 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 1 and pin 2 of the electrical connector.
NOTE: Electrical continuity between pin 1 and pin 2 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (OPEN).
7.On the test set:
  • Use the pressure regulator valve of the test set to decrease the pressure of the system to 0 psig (0.00 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully open.
Subtask 36-11-53-720-066-A ** ON A/C NOT FOR ALL
E. Do this Test
NOTE: The pressure value given in this test is applicable only to P/N 6740E01XXXX. Because the valves are interchangeable, it is necessary to do a check of the valve reference before the test. If the P/N reference is different from P/N 6740E01XXXX, refer to Para. B, C, D, F or G.
ACTION
RESULT
1.Pressurize the test set:
  • If there is a manometer in the air cylinder then the installation of the primary regulator valve is not necessary. Use the air cylinder shut off valve and the manometer to slowly pressurize the test set to 120 psig (8.27 bar rel.).
  • If there is no manometer in the air cylinder then the installation of primary regulator valve is mandatory. In this case the primary regulator valve will limit the pressure in the test set to 217 psig (14.96 bar rel.).

2.When you do the functional test for first time, apply a higher pressure than 110 psi (7.58 bar) to take off the clapper.

3.On the test set:
  • Open the shutoff valve.
  • Use the pressure regulator valve of the test set to slowly pressurize the system to 90 psig (6.21 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully closed when the pressure is between 81 psig (5.58 bar rel.) and 85 psig (5.86 bar rel.).
4.On the overpressure valve:
  • do a check of the electrical continuity between pin 2 and pin 3 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 2 and pin 3 of the electrical connector.
NOTE: Electrical continuity between pin 2 and pin 3 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (CLOSED).
NOTE: Read the pressure on the digital pressure gage.
NOTE: Read the pressure on the digital pressure gage.
5.On the test set:
  • Use the pressure regulator valve of the test set to slowly depressurize the system to open the overpressure valve.
On the overpressure valve (5HA):
  • The visual position indicator shows that the overpressure valve is fully open when the pressure is between 20 psig (1.38 bar rel.) and 57.20 (3.94 bar rel.).
NOTE: Read the pressure on the digital pressure gage.
6.On the overpressure valve:
  • do a check of the electrical continuity between pin 1 and pin 2 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 1 and pin 2 of the electrical connector.
NOTE: Electrical continuity between pin 1 and pin 2 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (OPEN).
7.On the test set:
  • Use the pressure regulator valve of the test set to decrease the pressure of the system to 0 psig (0.00 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully open.
Subtask 36-11-53-720-067-A ** ON A/C NOT FOR ALL
F. Do this Test
NOTE: The pressure value given in this test is applicable only to P/N 6740F01XXXX. Because the valves are interchangeable, it is necessary to do a check of the valve reference before the test. If the P/N reference is different from P/N 6740F01XXXX, refer to Para. B, C, D, E or G.
ACTION
RESULT
1.Pressurize the test set:
  • If there is a manometer in the air cylinder then the installation of the primary regulator valve is not necessary. Use the air cylinder shut off valve and the manometer to slowly pressurize the test set to 120 psig (8.27 bar rel.).
  • If there is no manometer in the air cylinder then the installation of primary regulator valve is mandatory. in this case the primary regulator valve will limit the pressure in the test set to 217 psig (14.96 bar rel.).

2.When you do the functional test for first time, apply a higher pressure than 110 psi (7.58 bar) to take off the clapper.

3.On the test set:
  • Open the shutoff valve.
  • Use the pressure regulator valve of the test set to slowly pressurize the system to 90 psig (6.21 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully closed when the pressure is between 81 psig (5.58 bar rel.) and 85 psig (5.86 bar rel.).
4.On the overpressure valve:
  • do a check of the electrical continuity between pin 2 and pin 3 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 2 and pin 3 of the electrical connector.
NOTE: Electrical continuity between pin 2 and pin 3 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (CLOSED).
NOTE: Read the pressure on the digital pressure gage.
NOTE: Read the pressure on the digital pressure gage.
5.On the test set:
  • Use the pressure regulator valve of test set to slowly depressurize the system to open the overpressure valve.
On the overpressure valve (5HA):
  • The visual position indicator shows that the overpressure valve is fully open when the pressure is between 29 psig (2.00 bar rel.) and 56 psig (3.86 bar rel.).
NOTE: Read the pressure on the digital pressure gage.
6.On the overpressure valve:
  • do a check of the electrical continuity between pin 1 and pin 2 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 1 and pin 2 of the electrical connector.
NOTE: Electrical continuity between pin 1 and pin 2 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (OPEN).
7.On the test set:
  • Use the pressure regulator valve of the test set to decrease the pressure of the system to 0 psig (0.00 bar rel.).
On the overpressure valve (5HA):
  • The visual position indicator shows that the valve is fully open.
Subtask 36-11-53-720-086-A ** ON A/C NOT FOR ALL
G. Do this test:
NOTE: The pressure value given in this test is applicable only to P/N 6740G010000. Because the valves are interchangeable, it is necessary to do a check of the valve reference before the test. If the P/N reference is different from P/N 6740G010000, refer to Para. B, C, D, E or F.
ACTION
RESULT
1.Pressurize the test set:
  • If there is a pressure gage in the air cylinder then the installation of the primary regulator valve is not necessary. Use the air cylinder shutoff valve and the pressure gage to slowly pressurize the test set to 120 psig (8.27 bar rel.).
  • If there is no pressure gage in the air cylinder then the installation of the primary regulator valve is mandatory. The primary regulator valve will keep the pressure in the test set to a maximum of 217 psig (14.96 bar rel.).

2.When you do the functional test for the first time, apply a pressure of more than 110 psi (7.58 bar) to take off the clapper.

3.On the test set:
  • Open the shutoff valve.
  • Use the pressure regulator valve of the test set to slowly pressurize the system to 95 psig (6.55 bar rel.).
On the overpressure valve:
  • The visual position indicator shows that the valve is fully closed when the pressure is between 80 psig (5.52 bar rel.) and 89.2 psig (6.15 bar rel.).
4.On the overpressure valve:
  • Do a check of the electrical continuity between pin 2 and pin 3 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 2 and pin 3 of the electrical connector.
NOTE: The electrical continuity between pin 2 and pin 3 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (CLOSED).
5.On the test set:
  • Use the pressure regulator valve of the test set to slowly depressurize the system to open the overpressure valve.
On the overpressure valve:
  • The visual position indicator shows that the overpressure valve is fully open when the pressure is between 50 psig (3.45 bar rel.) and 70 psig (4.83 bar rel.).
NOTE: Read the pressure on the digital pressure gage.
6.On the overpressure valve:
  • Do a check of the electrical continuity between pin 1 and pin 2 of the electrical connector with an OHMMETER MULTIRANGE.
On the OHMMETER MULTIRANGE:
  • There is electrical continuity between pin 1 and pin 2 of the electrical connector.
NOTE: The electrical continuity between pin 1 and pin 2 of the electrical connector shows that the overpressure valve position agrees with the microswitch position (OPEN).
7.On the test set:
  • Use the pressure regulator valve of the test set to decrease the pressure of the system to 0 psig (0.00 bar rel.).
On the overpressure valve:
  • The visual position indicator shows that the valve is fully open.
5. Close-up
Subtask 36-11-53-080-051-A ** ON A/C NOT FOR ALL
A. Disconnection of the Test Set
   (1) Close the shutoff valve of the air cylinder.
   (2) Slowly open the purge valve to release the pressure from the test set.
WARNING: BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT. THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
   (3) Disconnect the short bend flexible assembly from the test port of the overpressure valve and the 98L36103002000 TEST SET - ENGINE BLEED.
   (4) Disconnect the air cylinder from the 98L36103002000 TEST SET - ENGINE BLEED.
   (5) Lubricate the test port plug as follows:
  • For valve standard 6740B: Do not lubricate
  • For valve standard 6740E: Do not lubricate
  • For valve standard 6740F: Lubricate with Lubricant-Anti Seize High Temp. - (Material No.03PBB1)
  • For valve standard 6740G: Do not lubricate.
   (6) Install the blanking plug on the test port of the overpressure valve.
   (7) Torque the plug as follows:
   (8) Safety the blanking plug with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (9) Connect the electrical connector to the overpressure valve.
Subtask 36-11-53-410-056-A ** ON A/C NOT FOR ALL Subtask 36-11-53-440-053-A ** ON A/C NOT FOR ALL
C. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-53-410-057-A ** ON A/C NOT FOR ALL
D. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
Subtask 36-11-53-410-056-B ** ON A/C NOT FOR ALL
E. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-53-440-053-B ** ON A/C NOT FOR ALL
F. Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-53-410-057-B ** ON A/C NOT FOR ALL
G. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
Subtask 36-11-53-410-056-D ** ON A/C NOT FOR ALL
H. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
     (b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-53-440-053-D ** ON A/C NOT FOR ALL
I. Do the activation of the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 36-11-53-410-057-D ** ON A/C NOT FOR ALL
J. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
Subtask 36-11-53-862-053-A ** ON A/C NOT FOR ALL
K. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).