Removal of the Overpressure Valve
TASK 36-11-53-000-803-A
Removal of the Overpressure Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-53-861-060-A
Subtask 36-11-53-020-057-A
[Rev.10 from 2021]
2026.04.01 01:13:20 UTC
Removal of the Overpressure Valve
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803000000 | 1 | LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION |
| 98L12003001000 | AR | HARNESS,SAFETY |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 413 | UPPER FWD PYLON |
| 423 | UPPER FWD PYLON |
| 191DB | |
| FOR [7115HM1] (VALVE-OVERPRESSURE, ENG 1) | |
| 413CT | |
| FOR [7115HM2] (VALVE-OVERPRESSURE, ENG 2) | |
| 423CT | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-00-00-481-002-A | Installation of the Wingrip |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 54-52-11-000-807-A | Removal of the Access Skin Panels |
Subtask 36-11-53-861-060-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-53-941-061-A (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(3) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(4) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
(5) On access door 191DB, on the HP ground connector:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
(6) On FLAPS panel 114VU:
Subtask 36-11-53-865-065-A (1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(3) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(4) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
(5) On access door 191DB, on the HP ground connector:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
(6) On FLAPS panel 114VU:
- Put the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION in position on the flap/slat control lever.
- Put a WARNING NOTICE(S) in position on the flap/slat control lever to tell persons not to operate the flap/slat controls.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-53-010-071-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
D. Get Access
(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the pylon access panels.
(2) Remove this access panel (Ref. AMM TASK 54-52-11-000-807):
(a) FOR [7115HM1] (VALVE-OVERPRESSURE, ENG 1)
413CT
(b) FOR [7115HM2] (VALVE-OVERPRESSURE, ENG 2)
423CT
4. Procedure(1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the pylon access panels.
(2) Remove this access panel (Ref. AMM TASK 54-52-11-000-807):
(a) FOR [7115HM1] (VALVE-OVERPRESSURE, ENG 1)
413CT
(b) FOR [7115HM2] (VALVE-OVERPRESSURE, ENG 2)
423CT
Subtask 36-11-53-020-057-A
A. Removal of the T-Duct and Bellows
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(4) Remove the bellows (4) as follows:
(a) Loosen the couplings (3) and (5).
(b) Remove the couplings (3) and (5).
(c) Remove the bellows (4).
(d) Remove and discard the seal (2) from the starter duct (1).
(e) Remove and discard the seal (6) from the T-duct (9).
(5) Remove the T-duct (9) as follows:
(b) Remove the coupling (20).
(c) Remove the bolt (8), washer (7), bolt (10) and bushing (11).
(d) Loosen the coupling (13).
(e) Remove the coupling (13).
(f) Carefully remove the T-duct (9).
(g) Remove the two shims (19).
(h) Remove and discard the seal (12) from the T-duct (9).
(i) Remove and discard the special seal (22) from the ECS pipe (21).
(6) Put the PLUG-BLANKING in each disconnected line end.
Subtask 36-11-53-020-058-A (1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Record the position of the couplings (3), (5), (13) and (20) for the installation procedure. (4) Remove the bellows (4) as follows:
(a) Loosen the couplings (3) and (5).
(b) Remove the couplings (3) and (5).
(c) Remove the bellows (4).
(d) Remove and discard the seal (2) from the starter duct (1).
(e) Remove and discard the seal (6) from the T-duct (9).
(5) Remove the T-duct (9) as follows:
CAUTION:
WHEN YOU INSTALL OR REMOVE THE T-DUCT, BE VERY CAREFUL NOT TO LET THE REMOVABLE PARTS FALL INTO THE BLEED DUCT. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE EQUIPMENT CAN OCCUR.
(a) Loosen the coupling (20). (b) Remove the coupling (20).
(c) Remove the bolt (8), washer (7), bolt (10) and bushing (11).
(d) Loosen the coupling (13).
(e) Remove the coupling (13).
(f) Carefully remove the T-duct (9).
(g) Remove the two shims (19).
(h) Remove and discard the seal (12) from the T-duct (9).
(i) Remove and discard the special seal (22) from the ECS pipe (21).
(6) Put the PLUG-BLANKING in each disconnected line end.
B. Removal of the Overpressure Valve
(1) Disconnect the sense line (16) from the precooler exchanger (17).
(2) Hold the overpressure valve (18) and remove the clamp (14).
(3) Remove the overpressure valve (18).
(4) Remove and discard the seal (15) from the precooler exchanger (17).
(5) Install PLUG - BLANKING on the overpressure valve (18) and the precooler exchanger (17).
(6) Put the PLUG-BLANKING in each disconnected line end.
(7) Make sure that the work area is clean and clear of tools and other items.
(1) Disconnect the sense line (16) from the precooler exchanger (17).
(2) Hold the overpressure valve (18) and remove the clamp (14).
(3) Remove the overpressure valve (18).
(4) Remove and discard the seal (15) from the precooler exchanger (17).
(5) Install PLUG - BLANKING on the overpressure valve (18) and the precooler exchanger (17).
(6) Put the PLUG-BLANKING in each disconnected line end.
(7) Make sure that the work area is clean and clear of tools and other items.
Overpressure Valve