Functional Test of the Bleed Pressure Regulator-Valve with the Test Set P/N 98D36109001000
TASK 36-11-52-720-812-A
Functional Test of the Bleed Pressure Regulator-Valve with the Test Set P/N 98D36109001000
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-52-861-117-A Subtask 36-11-52-941-122-A
Subtask 36-11-52-750-051-A
Subtask 36-11-52-410-192-A
[Rev.10 from 2021]
2026.04.01 01:13:12 UTC
Functional Test of the Bleed Pressure Regulator-Valve with the Test Set P/N 98D36109001000
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BEFORE YOU INSTALL/REMOVE THE GSE TOOL, READ THE MANUFACTURER'S INSTRUCTIONS, AND, WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT DO THIS, INJURY TO PERSONS AND DAMAGE TO EQUIPMENT CAN OCCUR.
NOTE: Two persons are necessary to do this test.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH - STANDARD |
| No specific | Torque wrench: range to between 2.2 and 1.8 m.daN (16.22 and 13.27 lbf.ft ) ![]() | |
| 98D36109001000 | 1 | TEST SET-EBAS,BLEED |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 438AR, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 448AR, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-00-740-804-A | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
| TASK 78-36-00-410-806-A | Closing of the Thrust Reverser Cowl Doors |
Subtask 36-11-52-861-117-A Subtask 36-11-52-941-122-A
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On AIR COND panel 30VU:
Subtask 36-11-52-865-087-A (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On AIR COND panel 30VU:
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 36-11-52-010-200-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/APU BLEED VLV CTL/BMC1 OVRD | 11HV | D14 |
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
| 122VU | AIR BLEED/APU BLEED VLV CTL/BMC2 OVRD | 12HV | Z19 |
D. Get Access
(1) Open the right fan cowl-door (Ref. AMM TASK 71-13-00-010-803):
(2) FOR [1000EM1] (ENGINE-1)
438AR
(3) FOR [1000EM2] (ENGINE-2)
448AR.
Subtask 36-11-52-010-201-A (1) Open the right fan cowl-door (Ref. AMM TASK 71-13-00-010-803):
(2) FOR [1000EM1] (ENGINE-1)
438AR
(3) FOR [1000EM2] (ENGINE-2)
448AR.
E. Get Access
(1) Open the right thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-806).
(2) FOR [1000EM1] (ENGINE-1)
452AR
(3) FOR [1000EM2] (ENGINE-2)
462AR.
(4) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
4. Procedure(1) Open the right thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-010-806).
(2) FOR [1000EM1] (ENGINE-1)
452AR
(3) FOR [1000EM2] (ENGINE-2)
462AR.
(4) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-52-750-051-A
A. Mechanical Test of the Bleed-Pressure Regulator Valve (PRV)
(1) On the valve position indicator, record the position of the valve butterfly.
(2) Make sure that the valve butterfly moves freely.
Subtask 36-11-52-480-135-A (1) On the valve position indicator, record the position of the valve butterfly.
(2) Make sure that the valve butterfly moves freely.
- On the position indicator, use a WRENCH - STANDARD to fully open and fully close the valve butterfly.
- Put the valve butterfly in the initial position that you recorded.
B. Preparation for the Functional Test
(2) Connect manually the adaptor assembly to the test port of the bleed PRV.
(3) Connect manually the 98D36109001000 TEST SET-EBAS,BLEED with the short hose to the adaptor assembly.
(4) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98D36109001000 TEST SET-EBAS,BLEED.
(6) Set the digital pressure gage back to zero.
Subtask 36-11-52-720-134-A CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(1) Remove the blanking plug from the test port of the bleed PRV. (2) Connect manually the adaptor assembly to the test port of the bleed PRV.
(3) Connect manually the 98D36109001000 TEST SET-EBAS,BLEED with the short hose to the adaptor assembly.
(4) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98D36109001000 TEST SET-EBAS,BLEED.
NOTE: If the air cylinder has a regulator valve, it is not necessary to install the primary regulator valve supplied with the test set.
(5) Connect the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY to the 98D36109001000 TEST SET-EBAS,BLEED. (6) Set the digital pressure gage back to zero.
C. Functional Test of the Bleed-Pressure Regulator Valve
(1) Do this test:
Subtask 36-11-52-080-133-A (1) Do this test:
| ACTION | RESULT |
|---|---|
| 1.On the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY, open the shutoff valve. | On the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY, the cylinder pressure gage shows the pressure. |
| 2.On the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY, use the primary regulator to pressurize the pressure source to 43.5 psi (3.00 bar). | On the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY, the primary gage shows 43.5 psi (3.00 bar). |
3.On the 98D36109001000 TEST SET-EBAS,BLEED:
| |
4.In the cockpit:
| On the bleed PRV: The position indicator shows OPEN. |
5.In the cockpit:
NOTE: The pressure must be applied during all the test. NOTE: When the BITE test is completed, the valve closes. | On the bleed PRV: The position indicator shows CLOSED. |
6.On the 98D36109001000 TEST SET-EBAS,BLEED:
| On the PRV:
|
| 7.Depressurize the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY NOTE: The valve can stay open until the next engine start and will close automatically at the next engine start. | |
D. Disconnection of the Test Set
(2) Disconnect the adaptor assembly from the PRV.
(3) Install the blanking plug on the test port.
(4) TORQUE the blanking plug to between 2.2 and 1.8 m.daN (16.22 and 13.27 lbf.ft )
.
(5) Disconnect the 98D36109001000 TEST SET-EBAS,BLEED from the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY.
5. Close-upCAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(1) Disconnect the 98D36109001000 TEST SET-EBAS,BLEED and the short hose from the adaptor assembly. (2) Disconnect the adaptor assembly from the PRV.
(3) Install the blanking plug on the test port.
(4) TORQUE the blanking plug to between 2.2 and 1.8 m.daN (16.22 and 13.27 lbf.ft )
. (5) Disconnect the 98D36109001000 TEST SET-EBAS,BLEED from the AIR SOURCE 3 BAR (43.5 PSI) - REGULATED, FILTERED, DRY.
Subtask 36-11-52-410-192-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the right thrust-reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [1000EM1] (ENGINE-1)
452AR
(b) FOR [1000EM2] (ENGINE-2)
462AR.
Subtask 36-11-52-410-193-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the right thrust-reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [1000EM1] (ENGINE-1)
452AR
(b) FOR [1000EM2] (ENGINE-2)
462AR.
B. Close Access
(1) Close the right fan cowl-door (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [1000EM1] (ENGINE-1)
438AR
(b) FOR [1000EM2] (ENGINE-2)
448AR.
(2) Remove the WARNING NOTICE(S).
Subtask 36-11-52-862-114-A (1) Close the right fan cowl-door (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [1000EM1] (ENGINE-1)
438AR
(b) FOR [1000EM2] (ENGINE-2)
448AR.
(2) Remove the WARNING NOTICE(S).
Functional Test of the Bleed Pressure Regulator-Valve with the Test Set P/N 98D36109001000