W DOC AIRBUS | AMM A320F

Removal of the High Pressure Bleed Valve


TASK 36-11-51-000-042-A
Removal of the High Pressure Bleed Valve


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 453
FIN: 4000HA ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
453
HOT SECTION
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 49-00-00-860-006-A
APU Shutdown by External Power
TASK 49-00-00-860-006-A-01
APU Shutdown by Batteries
TASK 49-00-00-860-009-A
APU Shutdown by External Power (131-9(A))
TASK 49-00-00-860-009-A-01
APU Shutdown by Batteries (131-9(A))
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
3. Job Set-up
Subtask 36-11-51-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-51-941-051-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the engine 1(2) is shut down for at least 5 minutes.
   (2) On AIR COND panel 30VU:
     (a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
     (b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
     (c) Put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
   (3) On the center pedestal, on the ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than 5 minutes before you do this procedure.
     (c) put a WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
   (4) On the HP ground connector:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
   (5) On the ENG section of the MAINTENANCE panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR 1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 36-11-51-865-064-A ** ON A/C NOT FOR ALL
C. Open, safety and tag these circuit breakers in this sequence:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/MONG2HA2Z22
49VUAIR BLEED/ENG 1/CTL3HA1D12
122VUAIR BLEED/ENG 2/CTL3HA2Z23
Subtask 36-11-51-010-051-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
Subtask 36-11-51-040-053-A ** ON A/C NOT FOR ALL
E. Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 36-11-51-010-052-A ** ON A/C NOT FOR ALL
F. Open the left thrust reverser door (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL
   (2) FOR [1000EM2] (ENGINE-2)
461AL
4. Procedure
Subtask 36-11-51-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the High Pressure (HP) Bleed Valve
   (1) If you use the APU to energize the electrical circuits, stop the APU:
   (2) In the cockpit, on the SD bleed page:
     (a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (3) Disconnect the electrical connectors (4000HA-A) from the HP bleed valve (25).
   (4) Disconnect the HP sense tube from the HP bleed valve (25).
   (5) Remove the four couplings (15) and (30), the four E-seals (20) and (35), and the HP bleed valve (25) from the ducts (5), (10), (40) and (45).
   (6) Put the PLUG-BLANKING in each disconnected line end.
   (7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.