W DOC AIRBUS | AMM A320F

Remove the Thermostat-Filter of the Fan Air Valve-Control for Cleaning


TASK 36-11-43-100-001-A
Remove the Thermostat-Filter of the Fan Air Valve-Control for Cleaning


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 413
ZONE: 423
1. Reason for the Job
Refer to the MPD TASK: 361143-01
REMOVE THE THERMOSTAT-FILTER OF THE FAN AIR VALVE-CONTROL FOR CLEANING.

2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
413
UPPER FWD PYLON
423
UPPER FWD PYLON
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 36-11-43-000-003-A
Removal of the Filter of the Fan-Air Valve Control-Thermostat
TASK 36-11-43-400-003-A
Installation of the Filter of the Fan-Air-Valve Control Thermostat
3. Job Set-up
Subtask 36-11-43-010-057-A ** ON A/C NOT FOR ALL
A. Remove the filter (Ref. AMM TASK 36-11-43-000-003).
4. Procedure
Subtask 36-11-43-170-050-A ** ON A/C NOT FOR ALL
A. Cleaning of the Filter
   (1) Send the filter to the workshop to clean it.
5. Close-up
Subtask 36-11-43-410-053-A ** ON A/C NOT FOR ALL
A. Install the filter (Ref. AMM TASK 36-11-43-400-003).
[Rev.10 from 2021] 2026.04.01 01:09:28 UTC