Functional Test of the Differential Pressure Sensor (DPS) with the Bleed Test Set P/N 99127B04 and the Bleed Test Kit P/N 99127-281
TASK 36-11-18-720-802-A-01
Functional Test of the Differential Pressure Sensor (DPS) with the Bleed Test Set P/N 99127B04 and the Bleed Test Kit P/N 99127-281
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-18-861-056-A Subtask 36-11-18-941-056-A
Subtask 36-11-18-480-051-A
Subtask 36-11-18-410-054-A
[Rev.10 from 2021]
2026.04.01 01:08:56 UTC
Functional Test of the Differential Pressure Sensor (DPS) with the Bleed Test Set P/N 99127B04 and the Bleed Test Kit P/N 99127-281
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
WARNING:
MAKE SURE THAT THE SAFETY DEVICES AND THE WARNING NOTICES ARE IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BEFORE YOU INSTALL/REMOVE THE GSE TOOL, READ THE MANUFACTURER'S INSTRUCTIONS, AND, WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT DO THIS, INJURY TO PERSONS AND DAMAGE TO EQUIPMENT CAN OCCUR.
WARNING:
BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | 1 | AIR SOURCE - REGULATED, FILTERED, DRY |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | SUPPLY - 28 VDC, ELECTRICAL |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.84 and 0.83 m.daN (74.34 and 73.45 lbf.in ) ![]() | |
| 99127-281 | 1 | BLEED TEST KIT |
| 99127B04 | 1 | BLEED TEST SET |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 414 | UPPER FWD PYLON |
| 424 | UPPER FWD PYLON |
| FOR [18HA1] (XDCR-BLEED DIFFERENTIAL PRESS, ENG1) | |
| 414BR | |
| FOR [18HA2] (XDCR-BLEED DIFFERENTIAL PRESS, ENG2) | |
| 424BR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-00-740-804-A | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| TASK 54-52-11-000-807-A | Removal of the Access Skin Panels |
| TASK 54-52-11-400-807-A | Installation of the Access Skin Panels |
| TASK 78-30-00-040-807-A | Deactivation of the Thrust Reverser System for Nacelle Maintenance (ICU) |
| TASK 78-30-00-440-807-A | Reactivation of the Thrust Reverser System after Nacelle Maintenance (ICU) |
Subtask 36-11-18-861-056-A Subtask 36-11-18-941-056-A
B. Safety Precautions
(1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On AIR COND panel 30VU:
Subtask 36-11-18-865-060-A (1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On AIR COND panel 30VU:
- Make sure that ENG 1(2) BLEED pushbutton switch is released (OFF legend is on).
- Make sure that the APU BLEED pushbutton switch is released (ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell the persons not to start engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-18-040-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/APU BLEED VLV CTL/BMC1 OVRD | 11HV | D14 |
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
| 122VU | AIR BLEED/APU BLEED VLV CTL/BMC2 OVRD | 12HV | Z19 |
D. Deactivation of the Thrust Reverser System
Subtask 36-11-18-010-056-A WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the thrust reverser system (Ref. AMM TASK 78-30-00-040-807). E. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access.
(2) Remove the access panels (Ref. AMM TASK 54-52-11-000-807):
(a) FOR [18HA1] (XDCR-BLEED DIFFERENTIAL PRESS, ENG1)
414BR
(b) FOR [18HA2] (XDCR-BLEED DIFFERENTIAL PRESS, ENG2)
424BR.
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access.
(2) Remove the access panels (Ref. AMM TASK 54-52-11-000-807):
(a) FOR [18HA1] (XDCR-BLEED DIFFERENTIAL PRESS, ENG1)
414BR
(b) FOR [18HA2] (XDCR-BLEED DIFFERENTIAL PRESS, ENG2)
424BR.
Subtask 36-11-18-480-051-A
A. Preparation of the Functional Test of the DPS
(2) On the 99127B04 BLEED TEST SET (T01), make sure that:
(4) Connect an AIR SOURCE - REGULATED, FILTERED, DRY to the 99127B04 BLEED TEST SET (T01) pressure input (1) with the pneumatic supply connector (T02):
(a) Make sure that the AIR SOURCE - REGULATED, FILTERED, DRY is set to 0 psi (0.00 bar).
(5) Connect the 28VDC electrical cord (T03) between the 99127B04 BLEED TEST SET (T01) electrical inlet (11) and an external SUPPLY - 28 VDC, ELECTRICAL:
(a) Start the SUPPLY - 28 VDC, ELECTRICAL.
(6) Push the pushbutton (26) and make sure that lights come on from (15) to (21).
(7) Connect the yellow pneumatic hose (T04) between the Y-adaptor (T06) and the 99127B04 BLEED TEST SET (T01) pressure outlet (9).
(8) Connect the red pneumatic hose (T05) between the Y-adaptor (T06) and the 99127B04 BLEED TEST SET (T01) pressure outlet (14).
(9) Disconnect the HP sense line:
(10) Put the PLUG-BLANKING in each disconnected line end.
(11) Connect the test port adaptor (T43) to the HP sense line port of the DPS.
(12) Connect the Y-adaptor (T06) to the test port adaptor (T43).
(14) Put a CAP - BLANKING on electrical connector 18HA1-A (18AH2-A).
(16) Set the digital pressure gage (5) to ON:
(a) Make sure that the pressure value shown on the digital pressure gage (5) is equal to 0 psi (0.00 bar).
(b) If it is not equal to 0 psi (0.00 bar), push and hold the ON/OFF button for 10 seconds.
(17) Pressurize the 99127B04 BLEED TEST SET (T01):
Subtask 36-11-18-720-052-A CAUTION:
YOU MUST USE THE WRENCH FLATS ON THE MATING PARTS WHEN YOU LOOSEN OR TIGHTEN ANY OR ALL TUBE NUTS. THIS WILL PREVENT ANY TWIST DAMAGE TO THE TUBES.
(1) Use the 99127B04 BLEED TEST SET (T01) with the 99127-281 BLEED TEST KIT to do this test. (2) On the 99127B04 BLEED TEST SET (T01), make sure that:
- Pressure control knobs P1 (2) and P2 (3) are turned fully counterclockwise.
- The handles of the shut-off valves (6) and (7) are in the OFF position.
- The switches (24) and (25) are in position 2 (OFF).
- The knob (38) is in position 0.
- The stopwatch switch (19) is down (OFF).
- The multimeter knob (41) is in the OFF (vertical) position.
- The multimeter switch (28) is in position 1.
- The POWER SUPPLY knob (35) is turned fully counterclockwise.
- The SQUARE SIGNAL switch (34) is in the OFF position.
- The TORQUE MOTOR switch (33) is in the OFF position.
- The POWER switch (31) is in the OFF position.
CAUTION:
ONLY USE PNEUMATIC HOSES T04 AND T05 FROM THE LIEBHERR BLEED TEST SET 99127-B04. IF YOU USE DIFFERENT PNEUMATIC HOSES, YOU WILL GET INCORRECT TEST RESULTS.
(a) Make sure that you use the pneumatic hoses (T04) and (T05) available in the 99127B04 BLEED TEST SET (T01). (4) Connect an AIR SOURCE - REGULATED, FILTERED, DRY to the 99127B04 BLEED TEST SET (T01) pressure input (1) with the pneumatic supply connector (T02):
(a) Make sure that the AIR SOURCE - REGULATED, FILTERED, DRY is set to 0 psi (0.00 bar).
(5) Connect the 28VDC electrical cord (T03) between the 99127B04 BLEED TEST SET (T01) electrical inlet (11) and an external SUPPLY - 28 VDC, ELECTRICAL:
(a) Start the SUPPLY - 28 VDC, ELECTRICAL.
(6) Push the pushbutton (26) and make sure that lights come on from (15) to (21).
(7) Connect the yellow pneumatic hose (T04) between the Y-adaptor (T06) and the 99127B04 BLEED TEST SET (T01) pressure outlet (9).
(8) Connect the red pneumatic hose (T05) between the Y-adaptor (T06) and the 99127B04 BLEED TEST SET (T01) pressure outlet (14).
(9) Disconnect the HP sense line:
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTER TORQUE TO THE UNIONS WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES FROM/TO THE UNIONS. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN TWIST THE PNEUMATIC LINES AND CAUSE DAMAGE TO THEM.
(a) Disconnect the HP sense line port of the DPS. (10) Put the PLUG-BLANKING in each disconnected line end.
(11) Connect the test port adaptor (T43) to the HP sense line port of the DPS.
(12) Connect the Y-adaptor (T06) to the test port adaptor (T43).
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(13) Disconnect electrical connector 18HA1-A (18HA2-A) from the DPS. (14) Put a CAP - BLANKING on electrical connector 18HA1-A (18AH2-A).
CAUTION:
MAKE SURE THAT:
(15) Connect the electrical adaptor (T41) between the DPS and the electrical connector (29) of the 99127B04 BLEED TEST SET (T01), and tighten it with your hand. - YOU DO NOT APPLY HIGH LOADS WHEN YOU ENGAGE THE TEST PORT ADAPTOR IN THE VALVE OR THE SENSOR
- YOU TIGHTEN THE ADAPTOR MANUALLY. IF YOU APPLY A LOAD THAT IS TOO HIGH, DAMAGE TO THE PIN OF THE TEST PORT ADAPTOR CAN OCCUR.
(16) Set the digital pressure gage (5) to ON:
(a) Make sure that the pressure value shown on the digital pressure gage (5) is equal to 0 psi (0.00 bar).
(b) If it is not equal to 0 psi (0.00 bar), push and hold the ON/OFF button for 10 seconds.
(17) Pressurize the 99127B04 BLEED TEST SET (T01):
WARNING:
BE CAREFUL WHEN YOU PRESSURIZE THE BLEED TEST SET. THE MAXIMUM PRESSURE PERMITTED BY THE BLEED TEST SET IS 290 PSI. PRESSURE HIGHER THAN THE PRESSURE PERMITTED BY THE EQUIPMENT CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(a) Pressurize the 99127B04 BLEED TEST SET (T01) with the AIR SOURCE - REGULATED, FILTERED, DRY to between 100 psi (6.89 bar) and 200 psi (13.79 bar). B. Functional Test of the DPS
(1) Do this test:
Subtask 36-11-18-080-053-A (1) Do this test:
| ACTION | RESULT |
|---|---|
1.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
2.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
3.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
4.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
C. Disconnection of the Test Set
(2) Disconnect the Y-adaptor (T06) from the test port adaptor (T43).
(3) Disconnect the test port adaptor (T43) from the HP sense line port of the DPS.
(4) Remove the PLUG-BLANKING from each disconnected line end.
(5) Connect the HP sense line to the HP sense line port of the DPS:
.
(6) Disconnect the LP sense line from the DPS.
(7) Put the PLUG-BLANKING in each disconnected line end.
(8) Connect the test port adaptor (T25) to the LP sense line port of the DPS.
(9) Connect the Y-adaptor (T06) to the test port adaptor (T25).
Subtask 36-11-18-720-054-A WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(1) Make sure that the 99127B04 BLEED TEST SET (T01) shut-off valve is in OFF position and digital pressure gage shows 0 psi (0.00 bar). (2) Disconnect the Y-adaptor (T06) from the test port adaptor (T43).
(3) Disconnect the test port adaptor (T43) from the HP sense line port of the DPS.
(4) Remove the PLUG-BLANKING from each disconnected line end.
(5) Connect the HP sense line to the HP sense line port of the DPS:
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTER TORQUE TO THE UNIONS WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES FROM/TO THE UNIONS. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN TWIST THE PNEUMATIC LINES AND CAUSE DAMAGE TO THEM.
(a) TORQUE the nut of the HP sense line to between 0.84 and 0.83 m.daN (74.34 and 73.45 lbf.in )
. (6) Disconnect the LP sense line from the DPS.
(7) Put the PLUG-BLANKING in each disconnected line end.
(8) Connect the test port adaptor (T25) to the LP sense line port of the DPS.
(9) Connect the Y-adaptor (T06) to the test port adaptor (T25).
D. Functional Test of the DPS
(1) Do this test:
Subtask 36-11-18-080-051-A (1) Do this test:
| ACTION | RESULT |
|---|---|
| | On the 99127B04 BLEED TEST SET (T01):
|
1.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
2.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
3.On the 99127B04 BLEED TEST SET (T01):
| On the 99127B04 BLEED TEST SET (T01):
|
E. Disconnection of the Test Set
(2) Disconnect the test port adaptor (T25) from the LP sense line port of the DPS.
(3) Remove the PLUG-BLANKING from each disconnected line end.
(4) Connect the LP sense line to the LP sense line port of the DPS:
.
(5) Disconnect the electrical adaptor (T41) from the DPS.
(6) Remove the CAP - BLANKING from the harness electrical connector 18HA1-A (18HA2-A).
(8) Disconnect the electrical adaptor (T41) from the 99127B04 BLEED TEST SET (T01).
(9) Disconnect the Y-adaptor (T06) from the test port adaptor (T25).
(10) Disconnect the pneumatic hoses (T04) and (T05) from the 99127B04 BLEED TEST SET (T01) and the Y-adaptor (T06).
(11) Disconnect the pneumatic supply connector (T02) from the 99127B04 BLEED TEST SET (T01) and the AIR SOURCE - REGULATED, FILTERED, DRY.
(12) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(13) Disconnect the 28VDC electrical cord (T03) from the SUPPLY - 28 VDC, ELECTRICAL and the 99127B04 BLEED TEST SET (T01).
(14) Disconnect the pneumatic supply connector (T02) from the AIR SOURCE - REGULATED, FILTERED, DRY and the 99127B04 BLEED TEST SET (T01) pressure input (1).
(15) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 36-11-18-865-061-A WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(1) Close the shut-off valve of the AIR SOURCE - REGULATED, FILTERED, DRY to decrease the pressure of the 99127B04 BLEED TEST SET (T01) to 0 psi (0.00 bar). (2) Disconnect the test port adaptor (T25) from the LP sense line port of the DPS.
(3) Remove the PLUG-BLANKING from each disconnected line end.
(4) Connect the LP sense line to the LP sense line port of the DPS:
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTER TORQUE TO THE UNIONS WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES FROM/TO THE UNIONS. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN TWIST THE PNEUMATIC LINES AND CAUSE DAMAGE TO THEM.
(a) TORQUE the nut of the LP sense line to between 0.84 and 0.83 m.daN (74.34 and 73.45 lbf.in )
. (5) Disconnect the electrical adaptor (T41) from the DPS.
(6) Remove the CAP - BLANKING from the harness electrical connector 18HA1-A (18HA2-A).
CAUTION:
MAKE SURE THAT ELECTRICAL CONNECTORS ARE CLEAN WHEN YOU CONNECT THEM. THE CONTAMINATION OF ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO THE EQUIPMENT.
(7) Connect harness electrical connector 18HA1-A (18HA2-A) to the DPS and tighten it with your hand. (8) Disconnect the electrical adaptor (T41) from the 99127B04 BLEED TEST SET (T01).
(9) Disconnect the Y-adaptor (T06) from the test port adaptor (T25).
(10) Disconnect the pneumatic hoses (T04) and (T05) from the 99127B04 BLEED TEST SET (T01) and the Y-adaptor (T06).
(11) Disconnect the pneumatic supply connector (T02) from the 99127B04 BLEED TEST SET (T01) and the AIR SOURCE - REGULATED, FILTERED, DRY.
(12) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(13) Disconnect the 28VDC electrical cord (T03) from the SUPPLY - 28 VDC, ELECTRICAL and the 99127B04 BLEED TEST SET (T01).
(14) Disconnect the pneumatic supply connector (T02) from the AIR SOURCE - REGULATED, FILTERED, DRY and the 99127B04 BLEED TEST SET (T01) pressure input (1).
(15) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
F. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-11-18-740-051-A 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/APU BLEED VLV CTL/BMC1 OVRD | 11HV | D14 |
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
| 122VU | AIR BLEED/APU BLEED VLV CTL/BMC2 OVRD | 12HV | Z19 |
Subtask 36-11-18-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels (Ref. AMM TASK 54-52-11-400-807).
(a) FOR [18HA1] (XDCR-BLEED DIFFERENTIAL PRESS, ENG1)
414BR
(b) FOR [18HA2] (XDCR-BLEED DIFFERENTIAL PRESS, ENG2)
424BR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-18-440-051-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels (Ref. AMM TASK 54-52-11-400-807).
(a) FOR [18HA1] (XDCR-BLEED DIFFERENTIAL PRESS, ENG1)
414BR
(b) FOR [18HA2] (XDCR-BLEED DIFFERENTIAL PRESS, ENG2)
424BR.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
B. Reactivation of the Thrust Reverser System
(1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-807).
Subtask 36-11-18-862-054-A (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-807).
DPS with the Bleed Test Set P/N 99127B04 and the Bleed Test Kit P/N 99127-281