W DOC AIRBUS | AMM A320F

Functional Test of the Bleed Regulated Pressure-Transducer with the Bleed Test Set P/N 98D36109001000


TASK 36-11-16-720-802-A
Functional Test of the Bleed Regulated Pressure-Transducer with the Bleed Test Set P/N 98D36109001000


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: BEFORE YOU INSTALL/REMOVE THE GSE TOOL, READ THE MANUFACTURER'S INSTRUCTIONS, AND, WHILE YOU OPERATE THIS TOOL, CAREFULLY OBEY THEM. IF YOU DO NOT DO THIS, INJURY TO PERSONS AND DAMAGE TO EQUIPMENT CAN OCCUR.
CAUTION: BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT. THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
FIN: 8HA1 ** ON A/C NOT FOR ALL
FIN: 8HA2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
1
AIR SOURCE - REGULATED, FILTERED, DRY
No specific
AR
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
No specific
Torque wrench: range to between 0.84 and 0.83 m.daN (74.34 and 73.45 lbf.in ) T
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [8HA1] (XDCR-BLEED REGULATED PRESS, ENG 1)
415BL
FOR [8HA2] (XDCR-BLEED REGULATED PRESS, ENG 2)
425BL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-011-A
Procedure to Get Access to the SYSTEM REPORT/TEST/PNEU Page
FOR [8HA1] (XDCR-BLEED REGULATED PRESS, ENG 1)
TASK 54-51-21-000-802-A
Removal of the Pylon Lateral Access-Doors
TASK 54-51-21-400-802-A
Installation of the Pylon Lateral Access-Doors
FOR [8HA2] (XDCR-BLEED REGULATED PRESS, ENG 2)
TASK 54-51-21-000-802-A
Removal of the Pylon Lateral Access-Doors
TASK 54-51-21-400-802-A
Installation of the Pylon Lateral Access-Doors
3. Job Set-up
Subtask 36-11-16-861-058-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-16-941-057-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (2) On AIR COND panel 30VU:
  • Make sure that ENG 1(2) BLEED pushbutton switch is released (OFF legend is on).
  • Make sure that the APU BLEED pushbutton switch is released (ON legend is off).
  • Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
   (3) On ENG panel 115VU:
  • Put a WARNING NOTICE(S) in position to tell the persons not to start engine 1(2).
   (4) On the HP ground connector:
  • Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
   (5) On the ENG section of maintenance panel 50VU:
  • Make sure that the ON legend of ENG/FADEC GND PWR 1(2) pushbutton switch is off.
  • Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 36-11-16-865-062-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/APU BLEED VLV CTL/BMC1 OVRD11HVD14
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
122VUAIR BLEED/APU BLEED VLV CTL/BMC2 OVRD12HVZ19
Subtask 36-11-16-010-058-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the pylon access.
   (2) Remove the access panels:
     (a) FOR [8HA1] (XDCR-BLEED REGULATED PRESS, ENG 1)
415BL (Ref. AMM TASK 54-51-21-000-802)
     (b) FOR [8HA2] (XDCR-BLEED REGULATED PRESS, ENG 2)
425BL (Ref. AMM TASK 54-51-21-000-802).
Subtask 36-11-16-020-054-A ** ON A/C NOT FOR ALL
E. Disconnection of the Sense Line
CAUTION: USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
   (1) Disconnect the sense line from the Bleed Regulated Pressure-Transducer 8HA1 (8HA2).
   (2) Put the PLUG-BLANKING in each disconnected line end.
Subtask 36-11-16-860-063-A ** ON A/C NOT FOR ALL
F. Aircraft Maintenance Configuration
   (1) Adjust the brightness of the MCDU screen.
   (2) On one MCDU, get the SYSTEM REPORT/TEST PNEU/SENSOR STATUS menu page (Ref. AMM TASK 31-32-00-860-011).
F MCDU Valve Status Page ** ON A/C NOT FOR ALL
4. Procedure
Subtask 36-11-16-720-053-A ** ON A/C NOT FOR ALL
A. Functional Test of the Bleed Regulated Pressure-Transducer 8HA1(8HA2)
   (1) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98D36109001000 TEST SET-EBAS,BLEED.
   (2) Connect an AIR SOURCE - REGULATED, FILTERED, DRY to the 98D36109001000 TEST SET-EBAS,BLEED.
     (a) Connect the 98D36109001000 TEST SET-EBAS,BLEED to the test port of the Bleed Regulated Pressure Transducer 8HA1 (8HA2).
   (3) Set the digital pressure gage back to zero.
   (4) Make sure that the regulator valve of the 98D36109001000 TEST SET-EBAS,BLEED is closed before pressurize the system.
   (5) Do the test that follows:
ACTION
RESULT
1.On the MCDU control panel:
  • Push the SENSOR STATUS key.
On the MCDU:
  • The SENSOR STATUS page comes into view and shows the bleed pressure.
2.Pressurize the 98D36109001000 TEST SET-EBAS,BLEED:
  • If there is a manometer on the AIR SOURCE - REGULATED, FILTERED, DRY, installation of the primary regulator valve is not necessary. Use the AIR SOURCE - REGULATED, FILTERED, DRY shut off valve and the manometer to slowly pressurize the 98D36109001000 TEST SET-EBAS,BLEED to 100 psi (6.8948 bar).
  • If there is no manometer in the AIR SOURCE - REGULATED, FILTERED, DRY, installation of primary regulator valve is mandatory. In this case the primary regulator valve will limit the pressure in the 98D36109001000 TEST SET-EBAS,BLEED to 217 psi (14.9616 bar).

3.On the 98D36109001000 TEST SET-EBAS,BLEED:
  • Open the shutoff valve.
  • Use the regulator valve of the 98D36109001000 TEST SET-EBAS,BLEED to slowly pressurize the system from 10 psi (0.6895 bar) to 90 psi (6.2053 bar).
On the 98D36109001000 TEST SET-EBAS,BLEED:
  • The digital pressure gage shows the pressure.
On the SD:
  • The status page shows the supplied pressure which must agree with the value of the digital pressure gage plus or minus 2 psi (0.14 bar).
4.On the 98D36109001000 TEST SET-EBAS,BLEED:
  • Use the regulator valve of the 98D36109001000 TEST SET-EBAS,BLEED to depressurize the system.
On the 98D36109001000 TEST SET-EBAS,BLEED:
  • The digital pressure gage shows 0 psi (0.0000 bar).
   (6) Close the shutoff valve of the AIR SOURCE - REGULATED, FILTERED, DRY.
   (7) Slowly open the purge valve to depressurize the 98D36109001000 TEST SET-EBAS,BLEED to 0 psi (0.00 bar).
   (8) Disconnection of the 98D36109001000 TEST SET-EBAS,BLEED:
WARNING: BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
     (a) Disconnect the 98D36109001000 TEST SET-EBAS,BLEEDfrom the test port of the Bleed Regulated Pressure-Transducer 8HA1 (8HA2).
5. Close-up
Subtask 36-11-16-860-064-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Close the MCDU session.
   (2) Fully decrease the brightness of the MCDU screen (display off).
Subtask 36-11-16-420-055-A ** ON A/C NOT FOR ALL
B. Connection of the sense line:
   (1) Remove the PLUG-BLANKING from each disconnected line end.
   (2) Connect the sense line to the Bleed Regulated Pressure-Transducer 8HA1(8HA2).
CAUTION: USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
   (3) TORQUE the nut of the sense line to between 0.84 and 0.83 m.daN (74.34 and 73.45 lbf.in ) T.
Subtask 36-11-16-410-056-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panels:
     (a) FOR [
8HA1] (XDCR-BLEED REGULATED PRESS, ENG 1)
415BL (Ref. AMM TASK 54-51-21-400-802)
     (b) FOR [8HA2] (XDCR-BLEED REGULATED PRESS, ENG 2)
425BL (Ref. AMM TASK 54-51-21-400-802).
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 36-11-16-862-057-A ** ON A/C NOT FOR ALL
D. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 01:08:36 UTC