Installation of the Bleed Transferred Pressure-Transducer
TASK 36-11-15-400-802-A
Installation of the Bleed Transferred Pressure-Transducer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-15-861-057-A ** ON A/C NOT FOR ALL
Subtask 36-11-15-420-055-A ** ON A/C NOT FOR ALL
Subtask 36-11-15-410-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:08:15 UTC
Installation of the Bleed Transferred Pressure-Transducer
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.85 and 0.73 m.daN (75.22 and 64.60 lbf.in ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 415 | LOWER PYLON |
| 425 | LOWER PYLON |
| 191DB | |
| FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1) | |
| 415BL | |
| FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2) | |
| 425BL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-23-22-910-001-A | Marking of the Unions after Application of Standard or Specific Tightening Torque |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 36-11-00-740-802-A | BITE Test of the Engine Bleed Air System (EBAS) (System Test) |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
Subtask 36-11-15-861-057-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-15-860-056-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
(3) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(4) On the access door 191DB, on the HP ground connector:
(a) Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
Subtask 36-11-15-010-061-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Make sure that the WARNING NOTICE(S) is in position to tell persons not to operate the pneumatic system.
(3) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(4) On the access door 191DB, on the HP ground connector:
(a) Make sure that the WARNING NOTICE(S) is in position to tell persons not to pressurize the pneumatic system.
C. Get Access
(1) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position at the pylon access panels.
(2) Make sure that these access panels are removed:
(a) FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1)
415BL
(b) FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2)
425BL
Subtask 36-11-15-865-058-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position at the pylon access panels.
(2) Make sure that these access panels are removed:
(a) FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1)
415BL
(b) FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2)
425BL
D. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 7HA1 (XDCRBLEED TRANSFER PRESS, ENG 1) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 7HA2 (XDCRBLEED TRANSFER PRESS, ENG 2) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
Subtask 36-11-15-420-055-A ** ON A/C NOT FOR ALL
A. Installation of the Bleed Transferred Pressure-Transducer
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(4) Install the transducer (7) in the clamps (4):
(a) Make sure that you install the protective Teflon parts with the clamps (4).
(5) Put the transducer (7) and the clamps (4) in its position on the bracket (3).
(6) Install the washers (5) and the bolts (6).
(7) Tighten the bolts (6).
(8) Remove the PLUG-BLANKING from each disconnected line end.
(9) Connect the duct (1) to the transducer (7) and tighten it.
.
(11) Put a red line between the nut of the duct (1) and the transducer (7) (Ref. AMM TASK 20-23-22-910-001).
(12) Remove the CAP-BLANKING from each electrical connector and receptacle.
(13) Make sure that the electrical connector (2) is clean and in the correct condition.
(14) Connect the electrical connector (2) to the transducer (7).
Subtask 36-11-15-865-059-A ** ON A/C NOT FOR ALL (1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Do a visual inspection and clean the component interface and/or the adjacent area. (4) Install the transducer (7) in the clamps (4):
(a) Make sure that you install the protective Teflon parts with the clamps (4).
(5) Put the transducer (7) and the clamps (4) in its position on the bracket (3).
(6) Install the washers (5) and the bolts (6).
(7) Tighten the bolts (6).
(8) Remove the PLUG-BLANKING from each disconnected line end.
(9) Connect the duct (1) to the transducer (7) and tighten it.
NOTE: Use a second wrench to hold the union when you disconnect/connect the pneumatic sense lines on the union.
(10) TORQUE the nut of the duct (1) to between 0.85 and 0.73 m.daN (75.22 and 64.60 lbf.in )
. (11) Put a red line between the nut of the duct (1) and the transducer (7) (Ref. AMM TASK 20-23-22-910-001).
(12) Remove the CAP-BLANKING from each electrical connector and receptacle.
(13) Make sure that the electrical connector (2) is clean and in the correct condition.
(14) Connect the electrical connector (2) to the transducer (7).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-11-15-710-052-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 7HA1 (XDCRBLEED TRANSFER PRESS, ENG 1) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 7HA2 (XDCRBLEED TRANSFER PRESS, ENG 2) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
Subtask 36-11-15-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1)
415BL
(b) FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2)
425BL
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-15-862-056-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install these access panels:
(a) FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1)
415BL
(b) FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2)
425BL
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
(Ref. AMM TASK 24-41-00-862-002) or (Ref. AMM TASK 24-41-00-862-002).
Bleed Transferred Pressure-Transducer