Removal of the Bleed Transferred Pressure-Transducer
TASK 36-11-15-000-803-A
Removal of the Bleed Transferred Pressure-Transducer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-15-861-060-A
Subtask 36-11-15-020-056-A
[Rev.10 from 2021]
2026.04.01 01:08:16 UTC
Removal of the Bleed Transferred Pressure-Transducer
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 415 | LOWER PYLON |
| 425 | LOWER PYLON |
| 191DB | |
| FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1) | |
| 415BL | |
| FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2) | |
| 425BL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 26-21-41-000-001-F | Removal of the Engine Fire-Extinguisher Bottle |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 54-51-21-000-804-A | Removal of the Pylon Lateral Access-Doors |
Subtask 36-11-15-861-060-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-15-941-059-A (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(3) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(4) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
(5) On access door 191DB, on the HP ground connector:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
Subtask 36-11-15-865-062-A (1) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(2) On AIR COND panel 30VU:
(a) Make sure that the ENG 1(2) BLEED pushbutton switch is released (OFF legend on).
(b) Make sure that the APU BLEED pushbutton switch is released (ON legend off).
(c) Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
(3) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate the ENG/MODE selector switch and the ENG/MASTER 1(2) control switch.
(4) On the ENG section of maintenance panel 50VU:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
(5) On access door 191DB, on the HP ground connector:
(a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-15-010-064-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 7HA1 (XDCRBLEED TRANSFER PRESS, ENG 1) | |||
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| FOR FIN: 7HA2 (XDCRBLEED TRANSFER PRESS, ENG 2) | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
D. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels (Ref. AMM TASK 54-51-21-000-804):
(a) FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1)
415BL
(b) FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2)
425BL
(3) Remove the applicable engine fire-extinguisher bottle (Ref. AMM TASK 26-21-41-000-001).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the pylon access panels.
(2) Remove these access panels (Ref. AMM TASK 54-51-21-000-804):
(a) FOR [7HA1] (XDCR-BLEED TRANSFER PRESS, ENG 1)
415BL
(b) FOR [7HA2] (XDCR-BLEED TRANSFER PRESS, ENG 2)
425BL
(3) Remove the applicable engine fire-extinguisher bottle (Ref. AMM TASK 26-21-41-000-001).
Subtask 36-11-15-020-056-A
A. Removal of the Bleed Transferred Pressure-Transducer
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in the ambient conditions.
(4) Put a CAP - BLANKING on the disconnected electrical connector (2).
(5) Disconnect the duct (1) from the transducer (7).
(6) Remove the bolts (6) and the washers (5).
(7) Remove the clamps (4) and the transducer (7) from the bracket (3).
(8) Remove the transducer (7) from the clamps (4).
(9) Put PLUG - BLANKING on the end of the disconnected duct (1) and transducer (7).
(1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in the ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(3) Disconnect the electrical connector (2) from the transducer (7). (4) Put a CAP - BLANKING on the disconnected electrical connector (2).
(5) Disconnect the duct (1) from the transducer (7).
(6) Remove the bolts (6) and the washers (5).
(7) Remove the clamps (4) and the transducer (7) from the bracket (3).
(8) Remove the transducer (7) from the clamps (4).
(9) Put PLUG - BLANKING on the end of the disconnected duct (1) and transducer (7).
Bleed Transferred Pressure-Transducer