Health Check Procedure - Pressure Control Function
TASK 36-11-00-720-806-A
Health Check Procedure - Pressure Control Function
The Bleed Health Check procedure has a set of steps to do in order to check preventively the three primary functions of the EBAS. The initial recommended maintenance interval is every 20 months. However, as the ageing effects on EBAS equipment are linked to local parameters and operating environment, Airbus recommends to customize this interval based on operators own experience.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-112-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-116-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-720-076-B ** ON A/C NOT FOR ALL
Subtask 36-11-00-080-084-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:07:15 UTC
Health Check Procedure - Pressure Control Function
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
NOTE: In the health check procedures the electrical harness is in correct functioning condition.
1. Reason for the JobThe Bleed Health Check procedure has a set of steps to do in order to check preventively the three primary functions of the EBAS. The initial recommended maintenance interval is every 20 months. However, as the ageing effects on EBAS equipment are linked to local parameters and operating environment, Airbus recommends to customize this interval based on operators own experience.
- For A/C with HPV Solenoid Valve:
NOTE: Only applicable to A319 with (11HA) and A320 with IAE-2500 ENG and (4029KS)).
The pressure control function contains the High Pressure Bleed Valve (HPV) 4000HA, the High Pressure Valve Control Solenoid and the sense line that connects them with the Pressure Regulation Valve (PRV) 4001HA. - For A/C without HPV Solenoid Valve:
NOTE: Only applicable to A320.
The pressure control function contains the High Pressure Bleed Valve (HPV) 4000HA and the sense line that connects it with the Pressure Regulation Valve (PRV) 4001HA. - For A/C ALL
The pressure control function of the bleed system contains a flow chart that should be used for guidance. This flow chart gives a visual idea of the procedure.
In order to make easy the maintenance action sequence and to prevent any maintenance action that is not necessary, each AMM task is structured in a special flow chart.
Indeed is not necessary to test all components if the first test at function level is satisfactory. Also, sense line installation can be damaged during disconnection-reconnection for testing, and a systematic test of the sense line is not recommended. Leakage test at sense line level is required only if a need for troubleshooting is confirmed.
The operator can remove the components that have a drift, as given in the applicable flow chart, immediately or at the next maintenance unless there is an EWD message and the source of the CLASS1 failure is the component that has the drift. In this condition, you must refer to the MMEL/TSM for the aircraft dispatch.
NOTE: You can use bleed test set P/N 99127B04 as an alternative to bleed test set P/N 99127B03.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 2 | AIR SOURCE - REGULATED, FILTERED, DRY |
| No specific | 1 | SUPPLY - 28 VDC, ELECTRICAL |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH - TORQUE |
| No specific | AR | WRENCH 5/16 IN (8MM) - SPANNER |
| No specific | Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft ) ![]() | |
| 99127-231 | 1 | TEST SET BLEED - KIT |
| 99127B03 | 1 | BLEED TEST SET |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191MB | |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-00-720-008-A | Functional Test of the Sense Line Connected between the HP Bleed Valve and the Bleed-Pressure Regulator Valve with the Bleed Test Set P/N 99127B03 |
| TASK 36-11-00-720-008-A-01 | Functional Test of the Sense Line between the HP Bleed Valve and the Bleed- Pressure Regulator Valve with the Test Set P/N 98L36103002000 and P/N SBE2213 |
| TASK 36-11-00-720-819-A | Functional Check of the Pressure Regulating Valve (PRV) Control-Solenoid (10HA1, 10HA2) Non-Return-Function with the HP ground cart and the Bleed Test Set P/N 99127B03 |
| TASK 36-11-00-720-819-A-02 | Functional Check of the Pressure Regulating Valve (PRV) Control-Solenoid (10HA1, 10HA2) Non-Return-Function with the Engine Running |
| TASK 36-11-49-000-018-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-000-029-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-000-820-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-018-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-029-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-820-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-51-000-010-A | Removal of the HP Bleed Valve |
| TASK 36-11-51-000-040-A | Removal of the High Pressure Bleed Valve |
| TASK 36-11-51-000-042-A | Removal of the High Pressure Bleed Valve |
| TASK 36-11-51-400-010-A | Installation of the HP Bleed Valve |
| TASK 36-11-51-400-040-A | Installation of the High-Pressure Bleed Valve |
| TASK 36-11-51-400-042-A | Installation of the High-Pressure Bleed Valve |
| TASK 36-11-57-000-001-A | Removal of the High Pressure (HP) Bleed Valve Closure Control Solenoid |
| TASK 36-11-57-400-001-A | Installation of the High Pressure (HP) Bleed-Valve Closure Control-Solenoid |
| TASK 36-11-58-000-001-A | Removal of the HP-Bleed Override Solenoid |
| TASK 36-11-58-400-001-A | Installation of the HP-Bleed Override Solenoid |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-00-861-112-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-116-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-010-126-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is pushed (the OFF legend is off).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-085-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
D. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-127-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). E. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-126-B ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
F. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-085-B ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
G. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-127-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the Thrust-Reverser Hydraulic Control-Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). H. Open the left thrust-reverser half (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-126-C ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
I. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-085-C ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
J. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-127-C ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). K. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-480-084-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
L. Installation of the Tool for the Minimum Opening Pressure Test of the HPV (4000HA)
Sense Line Connected between the PRV and the HPV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the PRV and the HPV - Location ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773B and 6713D with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(2) Remove the blanking plug from the test port of HPV (4000HA).
(3) Install the test port adaptor (T14) or (T25) on the test port of the HPV (4000HA).
. If you have installed test port adaptor (T14), use your hand to tighten the adaptor.
(5) Connect Y adaptor as follows:
(a) Connect the Y adaptor (T06) to the test port adaptor (T14) or (T25).
(b) Connect the Y adaptor (T06) with the hose (T05) to the bleed-test set connector (14).
(c) Connect the Y adaptor (T06) with the hose (T04) to the bleed-test set connector (9).
(6) Use an AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through the item (1).
Subtask 36-11-00-720-084-A ** ON A/C NOT FOR ALL
Sense Line Connected between the PRV and the HPV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the PRV and the HPV - Location ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773B and 6713D with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Cut, remove and discard the lockwire of the blanking plug of the test port of HPV (4000HA). (2) Remove the blanking plug from the test port of HPV (4000HA).
(3) Install the test port adaptor (T14) or (T25) on the test port of the HPV (4000HA).
CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE PLUNGER PIN (T14). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T25). MAKE SURE THAT THE ADAPTOR (T14 OR T25) IS CORRECTLY TIGHTENED TO PREVENT DAMAGE TO THE BLEED TEST SET.
(4) Use a WRENCH - TORQUE to TORQUE the test port adaptor (T25) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. If you have installed test port adaptor (T14), use your hand to tighten the adaptor. (5) Connect Y adaptor as follows:
(a) Connect the Y adaptor (T06) to the test port adaptor (T14) or (T25).
(b) Connect the Y adaptor (T06) with the hose (T05) to the bleed-test set connector (14).
(c) Connect the Y adaptor (T06) with the hose (T04) to the bleed-test set connector (9).
(6) Use an AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through the item (1).
M. Minimum Opening Pressure Test of the HPV (4000HA) with the Bleed Test Set P/N 99127B03
(1) Install the tool for the minimum opening pressure test of the HPV (4000HA).
(2) Connect a 99127B03 BLEED TEST SET.
(a) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
(a) Make sure that the 99127B03 BLEED TEST SET is electrically powered up:
(a) For HPV standard 6773B and 6713D (Deactivation screw is on the right of the test port, in the valve body) with T25 installed:
Connection of the HPV STD 6773B and 6713D with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(b) For HPV standard 6773E (Deactivation screw is on the left of the test port, in the regulator) with T25 installed:
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(c) For HPV standard 6773F and 6773G (Deactivation screw on the left of the test port, in the regulator) with T14 installed:
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Subtask 36-11-00-480-085-A ** ON A/C NOT FOR ALL (1) Install the tool for the minimum opening pressure test of the HPV (4000HA).
(2) Connect a 99127B03 BLEED TEST SET.
NOTE: Use a 99127-231 TEST SET BLEED - KIT to do this test.
(3) Connect the 99127B03 BLEED TEST SET (T01) to a 28VDC power supply: (a) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
- Start the SUPPLY - 28 VDC, ELECTRICAL.
(a) Make sure that the 99127B03 BLEED TEST SET is electrically powered up:
- If 28VDC is supplied through an external power supply, turn the power supply to ON.
- Set the pressure gauge (5) to ON.
- The pressure value shown on the Liquid Crystal Display (LCD) screen must be equal to 0 psi (0.00 bar). If not, push the ON button for 10 seconds.
- Open the main pressure-source shut-off-valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 100 psi (6.89 bar).
(a) For HPV standard 6773B and 6713D (Deactivation screw is on the right of the test port, in the valve body) with T25 installed:
Connection of the HPV STD 6773B and 6713D with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the 99127B03 BLEED TEST SET:
| |
2.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
| | On the HPV:
|
3.On the 99127B03 BLEED TEST SET:
| |
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the 99127B03 BLEED TEST SET:
| |
2.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
| | On the HPV:
|
3.On the 99127B03 BLEED TEST SET:
| |
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the 99127B03 BLEED TEST SET:
| |
2.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
| | On the HPV:
|
3.On the 99127B03 BLEED TEST SET:
| |
N. Installation of the tool for the Opening/Closing Test of the HPV (4000HA)
(1) Install the tool for the Minimum Opening Pressure Test.
(2) Do a visual inspection of the HPV.
(3) For HPV standard 6773E, 6773F and 6773G:
Connection of HPV STD 6773E, 6773F and 6773G (with Deactivation Screw on Regulator) with Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(a) Removal of the lockwire.
(b) Remove the deactivation screw from the HPV (4000HA).
(e) Install the shut-off valve (T11) in the adaptor T15 or T19.
(f) Make sure that the shut-off valve (T11) is in the closed position.
(4) For HPV standard 6773B, and 6713D:
Connection of the HPV STD 6773B, 6773C and 6713D and PRV STD 6774E, 6774F and 6774G (without Deactivation Screw on regulator) with Bleed Test Set 99127B03 ** ON A/C NOT FOR ALL
5 Install the shut-off valve (T11) in the adaptor T15 or T19.
6 Make sure that the shut-off valve (T11) is in the closed position.
(b) If the PRV is not equipped with deactivation screw in the valve regulator (PRV 4001HA standard 6714D and 6774B):
Connection of HPV STD 6773B and 6713D (without Deactivation Screw on Regulator) and PRV STD 6774B and 6714D (with Deactivation Screw on Regulator) ** ON A/C NOT FOR ALL
1 The pressure-source shut-off valve (T11) is not valid for the opening/closing test of the HPV 4000HA.
2 The opening/closing command will be simulated through the bleed P/B in Air Conditioning Panel 30VU.
3 Two people are necessary to do the opening/closing test for these valve standards.
(5) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through Item (1).
Subtask 36-11-00-720-085-A ** ON A/C NOT FOR ALL (1) Install the tool for the Minimum Opening Pressure Test.
(2) Do a visual inspection of the HPV.
(3) For HPV standard 6773E, 6773F and 6773G:
Connection of HPV STD 6773E, 6773F and 6773G (with Deactivation Screw on Regulator) with Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Cut and discard the lockwire of the deactivation screw of the HPV. (b) Remove the deactivation screw from the HPV (4000HA).
CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
(c) Installation of the test port adaptor. - Install the test port adaptor (T15) or (T19) on the HPV 4000HA.EADED AREA
(e) Install the shut-off valve (T11) in the adaptor T15 or T19.
(f) Make sure that the shut-off valve (T11) is in the closed position.
(4) For HPV standard 6773B, and 6713D:
- Do a visual inspection of the PRV.
Connection of the HPV STD 6773B, 6773C and 6713D and PRV STD 6774E, 6774F and 6774G (without Deactivation Screw on regulator) with Bleed Test Set 99127B03 ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Removal of the lockwire. - Cut and discard the lockwire of the deactivation screw of the PRV 4001HA.
CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
3 Installation of the test port adaptor. - Install the test port adaptor (T15) or (T19) on the PRV 4001HA.
5 Install the shut-off valve (T11) in the adaptor T15 or T19.
6 Make sure that the shut-off valve (T11) is in the closed position.
(b) If the PRV is not equipped with deactivation screw in the valve regulator (PRV 4001HA standard 6714D and 6774B):
Connection of HPV STD 6773B and 6713D (without Deactivation Screw on Regulator) and PRV STD 6774B and 6714D (with Deactivation Screw on Regulator) ** ON A/C NOT FOR ALL 2 The opening/closing command will be simulated through the bleed P/B in Air Conditioning Panel 30VU.
3 Two people are necessary to do the opening/closing test for these valve standards.
(5) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through Item (1).
O. Opening/Closing Test of the HPV with Bleed Test Set P/N 99127B03
(1) Install the tool for the opening/closing test as follows:
(a) Connect the 99127B03 BLEED TEST SET.
1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
2 Start the SUPPLY - 28 VDC, ELECTRICAL.
(c) Do the power-up of the 99127B03 BLEED TEST SET:
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a Make sure that the pressure value shown on the Liquid Crystal Display (LCD) screen is equal to 0 psi (0 bar).
b If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
3 Do the test that follows to make sure that the lights of the bleed test set operate correctly:
(c) Tighten the screws of the connector (29).
(d) Connect the cable (T09) to the electrical connector (4000HA-A):
2 Make sure that you do not connect the cable (T09) to the connector (12).
(4) Connect the electrical connector cable (T08) from the 99127B03 BLEED TEST SET connector (12) to the HPV (4000HA) electrical connector:
(a) The light (15) automatically goes off.
(5) Connect the Y adaptor (T06) to the test port adaptor (T14) or (T25), installed in the test port of the HPV.
(6) Connect the Y adaptor (T06) with the hose (T05) to the bleed-test set connector (14).
(7) Connect the Y adaptor (T06) with the hose (T04) to the bleed-test set connector (9).
(a) For HPV standard 6773E, 6773F and 6773G, the pressure shut-off valve (T11) is installed in the HPV (4000HA):
Connection of HPV STD 6773E, 6773F and 6773G (with Deactivation Screw on Regulator) with Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(b) For HPV (4000HA) standards 6713D and 6773B and PRV (4001HA) standard 6774E, 6774F and 6774G, the shut-off valve (T11) is installed in the PRV (4001HA):
Connection of the HPV STD 6773B, 6773C and 6713D and PRV STD 6774E, 6774F and 6774G (without Deactivation Screw on regulator) with Bleed Test Set 99127B03 ** ON A/C NOT FOR ALL
(c) For HPV (4000HA) standards 6713D and 6773B and PRV (4001HA) standard 6774B and 6714D, the shut-off valve (T11) is not installed:
Connection of HPV STD 6773B and 6713D (without Deactivation Screw on Regulator) and PRV STD 6774B and 6714D (with Deactivation Screw on Regulator) ** ON A/C NOT FOR ALL
Subtask 36-11-00-480-087-A ** ON A/C NOT FOR ALL (1) Install the tool for the opening/closing test as follows:
(a) Connect the 99127B03 BLEED TEST SET.
NOTE: If necessary, you can use the 99127-231 TEST SET BLEED - KIT to do this test.
(b) Connect the 99127B03 BLEED TEST SET to a 28VDC power supply as follows: 1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
2 Start the SUPPLY - 28 VDC, ELECTRICAL.
(c) Do the power-up of the 99127B03 BLEED TEST SET:
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
- If the 28VDC is supplied through an external power supply, turn the power supply to the ON position.
a Make sure that the pressure value shown on the Liquid Crystal Display (LCD) screen is equal to 0 psi (0 bar).
b If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
3 Do the test that follows to make sure that the lights of the bleed test set operate correctly:
- Push the pushbutton (26) and make sure that the lights (15 to 21) come on.
CAUTION:
DO NOT TWIST OR BEND THE ELECTRICAL HARNESS WHEN YOU DISCONNECT/CONNECT THE ELECTRICAL CONNECTOR. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE HARNESS AND THUS CAUSE ELECTRICAL CIRCUIT DEFECTS.
(3) Connect the electrical connector cable (T09) from the 99127B03 BLEED TEST SET to the electrical connector (4000HA-A) as follows: CAUTION:
WHEN YOU CONNECT THE BLEED TEST SET, STRICTLY OBEY THE CONNECTION SEQUENCE GIVEN. IF YOU DO NOT, DAMAGE TO THE BLEED TEST SET CAN OCCUR.
(a) Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL: - Start the SUPPLY - 28 VDC, ELECTRICAL.
(c) Tighten the screws of the connector (29).
(d) Connect the cable (T09) to the electrical connector (4000HA-A):
NOTE: Usually, the bleed test-set light (17) comes on while you do the test of the HPV (4000HA).
1 The cable (T08) must not be connected to the connector (12) at this point.2 Make sure that you do not connect the cable (T09) to the connector (12).
(4) Connect the electrical connector cable (T08) from the 99127B03 BLEED TEST SET connector (12) to the HPV (4000HA) electrical connector:
(a) The light (15) automatically goes off.
(5) Connect the Y adaptor (T06) to the test port adaptor (T14) or (T25), installed in the test port of the HPV.
(6) Connect the Y adaptor (T06) with the hose (T05) to the bleed-test set connector (14).
(7) Connect the Y adaptor (T06) with the hose (T04) to the bleed-test set connector (9).
WARNING:
BE CAREFUL WHEN YOU PRESSURIZE THE BLEED TEST SET. THE MAXIMUM PRESSURE PERMITTED BY THE BLEED TEST SET IS 290 PSI. PRESSURE HIGHER THAN THE PRESSURE PERMITTED BY THE EQUIPMENT CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(8) Pressurize the 99127B03 BLEED TEST SET:- Make sure that the valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
- Slowly open the main pressure-source shut-off valve and pressurize the 99127B03 BLEED TEST SET (T01) to 100 psi (6.89 bar).
(a) For HPV standard 6773E, 6773F and 6773G, the pressure shut-off valve (T11) is installed in the HPV (4000HA):
Connection of HPV STD 6773E, 6773F and 6773G (with Deactivation Screw on Regulator) with Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
4.On the HPV:
| |
5.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
6.On the HPV:
| On the HPV:
|
7.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
8.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
| 9.On the HPV:
| On the HPV:
|
10.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
11.On the 99127B03 BLEED TEST SET:
| On the HPV:
|
Connection of the HPV STD 6773B, 6773C and 6713D and PRV STD 6774E, 6774F and 6774G (without Deactivation Screw on regulator) with Bleed Test Set 99127B03 ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
4.On the HPV:
| |
5.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
6.On the PRV:
| On the HPV:
|
7.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
8.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
| 9.On the PRV:
| On the HPV:
|
10.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
11.On the 99127B03 BLEED TEST SET:
| On the HPV:
|
Connection of HPV STD 6773B and 6713D (without Deactivation Screw on Regulator) and PRV STD 6774B and 6714D (with Deactivation Screw on Regulator) ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET
| On the 99127B03 BLEED TEST SET:
|
4.On the HPV:
| |
5.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
6.On overhead panel 30VU:
| On overhead panel 30VU:
|
7.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
8.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
| 9.On overhead panel 30VU:
| On overhead panel:
|
10.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
11.On the 99127B03 BLEED TEST SET:
| On the HPV:
|
P. Installation of the Tool for the Test of the HPV Solenoid Valve
(1) For HPV (4000HA) standards 6773E, 6773F and 6773G (HPV with the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(b) Remove the deactivation screw.
1 Use the 99127-231 TEST SET BLEED - KIT to do this test.
2 Connect the sense line tester (T10) to the HPV (4000HA) with the adaptor (T15) or (T19).
3 Tighten the adaptor (T15) or (T19) with your hand.
(d) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) to the test port adaptor (T15) or (T19) installed on the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(e) Connect the 99127B03 BLEED TEST SET (T01) to a 28VDC power supply as follows:
1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gage (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(g) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through item (1).
(2) For HPV (4000HA) standard 6773B and 6713D (HPV without the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(a) Connect the 99127B03 BLEED TEST SET (T01) to a 28VDC power supply:
1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered up:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gage (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(c) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) with the hose (T05) to the test port adaptor (T20) installed on the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(d) Disconnect the sense line between the HPV (4000HA) and the PRV (4001HA) as follows:
2 Shake the sense line with your hand to prevent cross thread damage to the pneumatic union.
3 Turn the union with your hand and not with a spanner, to prevent damage to the fitting end of the sense line.
4 Disconnect the sense line from the HPV (4000HA).
(e) Put the blanking plug (T16) on the HPV (4000HA).
(f) Connect the sense line adaptor (T20) as follows:
2 TORQUE the sense line adaptor (T20) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(g) Connect the sense line tester (T10) to the sense line adaptor (T20).
(h) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through item (1).
Subtask 36-11-00-480-087-B ** ON A/C NOT FOR ALL (1) For HPV (4000HA) standards 6773E, 6773F and 6773G (HPV with the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut, remove and discard the lockwire of the deactivation screw of the HPV (4000HA). (b) Remove the deactivation screw.
NOTE: You can use a WRENCH 5/16 IN (8MM) - SPANNER to remove the deactivation screw.
CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
(c) Connect the sense line tester to the HPV (4000HA) as follows:1 Use the 99127-231 TEST SET BLEED - KIT to do this test.
2 Connect the sense line tester (T10) to the HPV (4000HA) with the adaptor (T15) or (T19).
3 Tighten the adaptor (T15) or (T19) with your hand.
(d) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) to the test port adaptor (T15) or (T19) installed on the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(e) Connect the 99127B03 BLEED TEST SET (T01) to a 28VDC power supply as follows:
1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
- Start the SUPPLY - 28 VDC, ELECTRICAL.
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gage (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(g) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through item (1).
(2) For HPV (4000HA) standard 6773B and 6713D (HPV without the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL 1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
- Start the SUPPLY - 28 VDC, ELECTRICAL.
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered up:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gage (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(c) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) with the hose (T05) to the test port adaptor (T20) installed on the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(d) Disconnect the sense line between the HPV (4000HA) and the PRV (4001HA) as follows:
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
1 Loosen the pneumatic union of the sense line installed on the HPV (4000HA) a quarter turn with a spanner. 2 Shake the sense line with your hand to prevent cross thread damage to the pneumatic union.
3 Turn the union with your hand and not with a spanner, to prevent damage to the fitting end of the sense line.
4 Disconnect the sense line from the HPV (4000HA).
(e) Put the blanking plug (T16) on the HPV (4000HA).
(f) Connect the sense line adaptor (T20) as follows:
CAUTION:
MAKE SURE THE ADAPTOR T20 IS CORRECTLY TIGHTENED ON THE SENSE LINE.
1 Connect the sense line adaptor (T20) to the sense line union. 2 TORQUE the sense line adaptor (T20) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (g) Connect the sense line tester (T10) to the sense line adaptor (T20).
(h) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through item (1).
P. Installation of the Tool for the Test of the HPV Solenoid Valve
(1) For HPV (4000HA) standards 6773E, 6773F and 6773G (HPV with the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(b) Remove the deactivation screw.
1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL:
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
1 Use the 99127-231 TEST SET BLEED - KIT to do this test.
2 Connect the sense line tester (T10) to the HPV (4000HA) with the adaptor (T15) or (T19).
3 Apply force when you tighten the adaptor (T15) or (T19) with your hand.
(f) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) to the test port adaptor (T15) or (T19) installed in the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(2) For HPV (4000HA) standard 6773B and 6713D (HPV without the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(a) Connect the 99127B03 BLEED TEST SET (T01) to a 28VDC power supply:
1 Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(c) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) with the hose (T05) to the test port adaptor (T20) installed in the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(d) Disconnect the sense line between the HPV (4000HA) and the PRV (4001HA) as follows:
2 Shake the sense line with your hand to prevent cross thread damage to the pneumatic union.
3 Turn the union with your hand and not with a spanner, to prevent damage to the fitting end of the sense line.
4 Disconnect the sense line from the HPV (4000HA).
(e) Put the blanking plug (T16) on the HPV (4000HA).
(f) Connect the sense line adaptor (T20) as follows:
2 TORQUE the sense line adaptor (T20) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(g) Connect the sense line tester (T10) to the sense line adaptor (T20).
(3) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through item (1).
Subtask 36-11-00-720-086-A ** ON A/C NOT FOR ALL (1) For HPV (4000HA) standards 6773E, 6773F and 6773G (HPV with the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut, remove and discard the lockwire of the deactivation screw of the HPV (4000HA). (b) Remove the deactivation screw.
NOTE: You can use a WRENCH 5/16 IN (8MM) - SPANNER to remove the deactivation screw.
(c) Connect the 99127B03 BLEED TEST SET (T01) to a 28VDC power supply as follows: 1 Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL:
- Start the SUPPLY - 28 VDC, ELECTRICAL.
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
(e) Connect the sense line tester to the HPV (4000HA) as follows: 1 Use the 99127-231 TEST SET BLEED - KIT to do this test.
2 Connect the sense line tester (T10) to the HPV (4000HA) with the adaptor (T15) or (T19).
3 Apply force when you tighten the adaptor (T15) or (T19) with your hand.
(f) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) to the test port adaptor (T15) or (T19) installed in the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(2) For HPV (4000HA) standard 6773B and 6713D (HPV without the deactivation screw on the regulator):
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL 1 Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL:
- Start the SUPPLY - 28 VDC, ELECTRICAL.
1 Make sure that the 99127B03 BLEED TEST SET is electrically powered:
a If 28VDC is supplied through an external power supply, turn the power supply to ON.
b Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
c If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(c) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as follows:
1 Connect the sense line tester (T10) with the hose (T05) to the test port adaptor (T20) installed in the test port of the HPV (4000HA).
2 Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
3 Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(d) Disconnect the sense line between the HPV (4000HA) and the PRV (4001HA) as follows:
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
1 Loosen the pneumatic union of the sense line to the HPV (4000HA) a quarter turn with a spanner. 2 Shake the sense line with your hand to prevent cross thread damage to the pneumatic union.
3 Turn the union with your hand and not with a spanner, to prevent damage to the fitting end of the sense line.
4 Disconnect the sense line from the HPV (4000HA).
(e) Put the blanking plug (T16) on the HPV (4000HA).
(f) Connect the sense line adaptor (T20) as follows:
CAUTION:
MAKE SURE THE ADAPTOR T20 IS CORRECTLY TIGHTENED ON THE SENSE LINE.
1 Connect the sense line adaptor (T20) to the sense line union. 2 TORQUE the sense line adaptor (T20) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (g) Connect the sense line tester (T10) to the sense line adaptor (T20).
(3) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through item (1).
Q. Functional test of the HPV Solenoid Valve
(1) Install the tools for the functional test of the HPV Solenoid Valve.
Subtask 36-11-00-720-116-A ** ON A/C NOT FOR ALL (1) Install the tools for the functional test of the HPV Solenoid Valve.
WARNING:
BE CAREFUL WHEN YOU PRESSURIZE THE BLEED TEST SET. THE MAXIMUM PRESSURE PERMITTED BY THE BLEED TEST SET IS 290 PSI. PRESSURE HIGHER THAN THE PRESSURE PERMITTED BY THE EQUIPMENT CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(a) Pressurize the 99127B03 BLEED TEST SET. - Make sure both valves (item 1 and item 2) are closed in the sense line tester.
- Make sure both valves (item 6 and item 7) are closed in the 99127B03 BLEED TEST SET .
- Open the main pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET to 100 psi (6.89 bar).
| ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
4.On the HPV solenoid valve:
| On the HPV solenoid valve:
|
5.On the 99127B03 BLEED TEST SET
| |
R. Functional Check of the Pressure Regulating Valve (PRV) Control-Solenoid (10HA1, 10HA2) Non-Return-Function
(1) Do the functional check (Ref. AMM TASK 36-11-00-720-819).
4. Procedure(1) Do the functional check (Ref. AMM TASK 36-11-00-720-819).
Subtask 36-11-00-720-076-B ** ON A/C NOT FOR ALL
A. Health Check Procedure for the Pressure Control Function with Solenoid Installed
Subtask 36-11-00-720-076-E ** ON A/C NOT FOR ALL - Do the minimum opening pressure-test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the close up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-029) and (Ref. AMM TASK 36-11-49-400-029).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the functional test of the HPV solenoid valve.
- Replace the HPV solenoid valve (Ref. AMM TASK 36-11-58-000-001) and (Ref. AMM TASK 36-11-58-400-001).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- If there is a leak:
* Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph. - If there is no leak:
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
A. Health Check Procedure for the Pressure Control Function with Solenoid Installed
Subtask 36-11-00-720-083-D ** ON A/C NOT FOR ALL - Do the minimum opening pressure-test of the HPV
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the close up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-018) and (Ref. AMM TASK 36-11-49-400-018).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the functional test of the HPV solenoid valve.
- Replace the HPV solenoid valve (Ref. AMM TASK 36-11-57-000-001) and (Ref. AMM TASK 36-11-57-400-001).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- If there is a leak:
* Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph. - If there is no leak:
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
B. Health Check Procedure for the Pressure Control Function without Solenoid Installed
Subtask 36-11-00-720-083-F ** ON A/C NOT FOR ALL - Do the minimum opening pressure-test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-042) and (Ref. AMM TASK 36-11-51-400-042).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-042) and (Ref. AMM TASK 36-11-51-400-042).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-820) and (Ref. AMM TASK 36-11-49-400-820) .
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-042) and (Ref. AMM TASK 36-11-51-400-042).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
B. Health Check Procedure for the Pressure Control Function without Solenoid Installed
5. Close-up- Do the minimum opening pressure-test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the close up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-018) and (Ref. AMM TASK 36-11-49-400-018).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
Subtask 36-11-00-080-084-A ** ON A/C NOT FOR ALL
A. Removal of the Tool for the HPV Solenoid Valve test
(1) For the HPV (4000HA) with the deactivation screw on the regulator:
(a) Disconnect and remove the adaptor (T15) or (T19), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the HPV (4000HA) as follows:
1 Disconnect the sense line tester (T10) from the test port adaptor (T15) or (T19) installed in the test port of the HPV (4000HA).
2 Disconnect the sense line tester (T10) with the hose (T05) from the bleed test-set connector (14).
3 Disconnect the sense line tester (T10) with the hose (T04) from the bleed test-set connector (9).
(b) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(c) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(f) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(2) For the HPV (4000HA) without deactivation screw on the regulator:
(a) Disconnect and remove the 99127B03 BLEED TEST SET (T01), the sense line tester (T10) and the sense line adaptor (T20) from the sense line union as follows:
1 Disconnect the sense line tester (T10) from the sense line adaptor (T20) installed in the test port of the HPV (4000HA).
2 Disconnect the sense line tester (T10) with the hose (T05) from the bleed test-set connector (14).
3 Disconnect the sense line tester (T10) with the hose (T04) from the bleed test-set connector (9).
(b) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(c) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(d) Remove the blanking plug (T16) from the HPV.
1 Make sure that there is no grease or oil on the pneumatic and sense line unions.
2 Connect the sense line to the HPV:
a To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
3 Do the double torque method on the union of the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
as follows:
a TORQUE the union of the sense line to the given value.
b Loosen the union of the sense line a quarter of a turn.
c TORQUE the union of the sense line again to the given value
4 Make a mark on the union of the sense line with paint.
Subtask 36-11-00-080-082-A ** ON A/C NOT FOR ALL (1) For the HPV (4000HA) with the deactivation screw on the regulator:
(a) Disconnect and remove the adaptor (T15) or (T19), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the HPV (4000HA) as follows:
1 Disconnect the sense line tester (T10) from the test port adaptor (T15) or (T19) installed in the test port of the HPV (4000HA).
2 Disconnect the sense line tester (T10) with the hose (T05) from the bleed test-set connector (14).
3 Disconnect the sense line tester (T10) with the hose (T04) from the bleed test-set connector (9).
(b) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(c) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(d) Install the deactivation screw as follows: NOTE: If the adaptor (T19) is installed, the deactivation screw is installed with a preformed packing. Airbus recommends you to replace the preformed packing with a new one.
(e) Install the deactivation screw on the HPV (4000HA). (f) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(g) Safety the deactivation screw on its support with the (2) For the HPV (4000HA) without deactivation screw on the regulator:
(a) Disconnect and remove the 99127B03 BLEED TEST SET (T01), the sense line tester (T10) and the sense line adaptor (T20) from the sense line union as follows:
1 Disconnect the sense line tester (T10) from the sense line adaptor (T20) installed in the test port of the HPV (4000HA).
2 Disconnect the sense line tester (T10) with the hose (T05) from the bleed test-set connector (14).
3 Disconnect the sense line tester (T10) with the hose (T04) from the bleed test-set connector (9).
(b) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(c) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(d) Remove the blanking plug (T16) from the HPV.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(e) Connect the sense line as follows: 1 Make sure that there is no grease or oil on the pneumatic and sense line unions.
2 Connect the sense line to the HPV:
a To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
3 Do the double torque method on the union of the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
as follows:a TORQUE the union of the sense line to the given value.
b Loosen the union of the sense line a quarter of a turn.
c TORQUE the union of the sense line again to the given value
4 Make a mark on the union of the sense line with paint.
B. Removal of the tool for opening/closing test
Connection of HPV STD 6773E, 6773F and 6773G (with Deactivation Screw on Regulator) with Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773B, 6773C and 6713D and PRV STD 6774E, 6774F and 6774G (without Deactivation Screw on regulator) with Bleed Test Set 99127B03 ** ON A/C NOT FOR ALL
(1) Disconnect the test port adaptor (T14) or (T25) from the test port of the HPV (4000HA) as follows:
(a) Disconnect the hose (T05) from the bleed test-set connector (14) and the Y adaptor (T06).
(b) Disconnect the hose (T04) from the bleed test-set connector (9) and the Y adaptor (T06).
(c) Disconnect the Y adaptor (T06) from the test port adaptor (T14) or (T25) installed in the test port of the HPV (4000HA).
(2) Disconnect the shut-off valve (T11) from the adaptor (T15) or (T19).
(3) Disconnect the adaptor (T15) or (T19):
(a) From the HPV (4000HA) if installed.
(b) From the PRV (4001HA) if installed.
(4) Disconnect the electrical connector cable (T09) from the electrical connector (4000HA-A).
(5) Disconnect the cable (T09) from the connector (29).
(6) Disconnect the electrical connector cable (T08) from the connector (12) of the 99127B03 BLEED TEST SET and the HPV (4000HA) electrical connector.
(7) Loosen the screws of the connector (29).
(8) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(9) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(10) If disconnected, connect the sense line to HPV (4000HA).
(11) If removed, install the deactivation screw as follows:
.
(12) Install the blanking cap on the test port of the HPV (4000HA).
(13) TORQUE the blanking cap to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(15) Connect the electrical connector (4000HA-A) as follows:
(a) Make sure that all the electrical connections are clean and in the correct condition.
(b) Connect the electrical connector (4000HA-A) to the HPV (4000HA).
(c) Tighten the connector by hand plus one-eighth turn.
Subtask 36-11-00-080-083-A ** ON A/C NOT FOR ALL
Connection of HPV STD 6773E, 6773F and 6773G (with Deactivation Screw on Regulator) with Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773B, 6773C and 6713D and PRV STD 6774E, 6774F and 6774G (without Deactivation Screw on regulator) with Bleed Test Set 99127B03 ** ON A/C NOT FOR ALL (a) Disconnect the hose (T05) from the bleed test-set connector (14) and the Y adaptor (T06).
(b) Disconnect the hose (T04) from the bleed test-set connector (9) and the Y adaptor (T06).
(c) Disconnect the Y adaptor (T06) from the test port adaptor (T14) or (T25) installed in the test port of the HPV (4000HA).
(2) Disconnect the shut-off valve (T11) from the adaptor (T15) or (T19).
(3) Disconnect the adaptor (T15) or (T19):
(a) From the HPV (4000HA) if installed.
(b) From the PRV (4001HA) if installed.
(4) Disconnect the electrical connector cable (T09) from the electrical connector (4000HA-A).
(5) Disconnect the cable (T09) from the connector (29).
(6) Disconnect the electrical connector cable (T08) from the connector (12) of the 99127B03 BLEED TEST SET and the HPV (4000HA) electrical connector.
(7) Loosen the screws of the connector (29).
(8) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(9) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(10) If disconnected, connect the sense line to HPV (4000HA).
(11) If removed, install the deactivation screw as follows:
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(a) Install the deactivation screw on the HPV (4000HA). NOTE: If the adaptor (T19) is installed, the deactivation screw has a preformed packing. Airbus recommends you to replace the preformed packing with a new one.
(b) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. (12) Install the blanking cap on the test port of the HPV (4000HA).
(13) TORQUE the blanking cap to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(14) Safety the deactivation screw and the blanking cap with a (15) Connect the electrical connector (4000HA-A) as follows:
(a) Make sure that all the electrical connections are clean and in the correct condition.
(b) Connect the electrical connector (4000HA-A) to the HPV (4000HA).
(c) Tighten the connector by hand plus one-eighth turn.
C. Removal of the Tool for the Minimum Opening Pressure
Connection of the HPV STD 6773B and 6713D with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(1) Remove the test port adaptor (T14) or (T25) from the test port of the HPV (4000HA) as follows:
(a) Disconnect the hose (T05) from the bleed test-set connector (14) and the Y adaptor (T06).
(b) Disconnect the hose (T04) from the bleed test-set connector (9) and the Y adaptor (T06).
(c) Disconnect the Y adaptor (T06) from the test port adaptor (T14) or (T25) installed in the test port of the HPV (4000HA).
(2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Install the blanking plug on the test port of the HPV (4000HA).
(5) TORQUE the blanking plug to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
Subtask 36-11-00-410-125-A ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773B and 6713D with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Connection of the HPV STD 6773E, 6773F and 6773G with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL (a) Disconnect the hose (T05) from the bleed test-set connector (14) and the Y adaptor (T06).
(b) Disconnect the hose (T04) from the bleed test-set connector (9) and the Y adaptor (T06).
(c) Disconnect the Y adaptor (T06) from the test port adaptor (T14) or (T25) installed in the test port of the HPV (4000HA).
(2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Install the blanking plug on the test port of the HPV (4000HA).
(5) TORQUE the blanking plug to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(6) Safety the blanking plug with the D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-083-A ** ON A/C NOT FOR ALL Subtask 36-11-00-410-126-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
F. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-125-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
G. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-083-B ** ON A/C NOT FOR ALL Subtask 36-11-00-410-126-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
I. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-11-00-410-125-C ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
J. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-083-C ** ON A/C NOT FOR ALL Subtask 36-11-00-410-126-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
L. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-862-098-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).