Health Check Procedure - Pressure Control Function with the Bleed Test Set P/N 98L36103002000
TASK 36-11-00-720-806-A-01
Health Check Procedure - Pressure Control Function with the Bleed Test Set P/N 98L36103002000
The Bleed Health Check procedure has a set of steps to do in order to first check the three primary functions of the EBAS.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-138-B ** ON A/C NOT FOR ALL Subtask 36-11-00-941-140-B ** ON A/C NOT FOR ALL
Subtask 36-11-00-720-098-F ** ON A/C NOT FOR ALL
Subtask 36-11-00-080-098-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:07:16 UTC
Health Check Procedure - Pressure Control Function with the Bleed Test Set P/N 98L36103002000
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
NOTE: In the Health Check Procedures the electrical harness is in serviceable condition.
1. Reason for the JobThe Bleed Health Check procedure has a set of steps to do in order to first check the three primary functions of the EBAS.
- For A/C with HPV SOL valve 11HA:
The pressure control function contains the High Pressure Bleed Valve (HPV) (4000HA), the High Pressure Valve Control Solenoid (11HA) (referred to in this procedure as HPV solenoid valve) and the sense line that connects them with the Pressure Regulation Valve (PRV) (4001HA). - For A/C with HPV SOL Valve 4029KS:
The pressure control function contains the HPV (4000HA), the High Pressure Valve Control Solenoid (4029KS) (referred to in this procedure as HPV solenoid valve) and the sense line that connects them with the PRV (4001HA). - For A/C without HPV SOL Valve:
The pressure control function contains the HPV (4000HA) and the sense line that connects it with the PRV (4001HA).
The pressure control function of the bleed system contains a flow chart that can be used as instruction. This flow chart gives a visual idea of the procedure.
In order to make easy the maintenance step sequence and to prevent maintenance procedures that are not necessary, each AMM task has the structure of a special flow chart.
It is not necessary to test all components if the first test at function level is satisfactory. Also, sense line installation can be damaged during disconnection-reconnection for testing, and a systematic test of the sense line is not recommended. Leakage test at sense line level is mandatory only if the troubleshooting is necessary.
The operator can remove the components that have a drift, as given in the applicable flow chart, immediately or at the next maintenance unless there is an EWD message and the source of the CLASS1 failure is the component that has the drift. In this condition, you must refer to the MMEL/TSM for the aircraft dispatch.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY |
| No specific | 1 | GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY |
| No specific | 1 | PACKING |
| No specific | 1 | PLUG - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH 5/16 IN (8MM) - SPANNER |
| No specific | Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft ) ![]() | |
| 98L36103002000 | 1 | TEST SET - ENGINE BLEED |
| M82000879 | 1 | TEST PORT UNIVERSAL |
| SBE2213 | 1 | KIT TOOL-TESTER SENSE LINE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.04SAB2) | Varnish Polyurethane-- Marking Structure |
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191MB | |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-00-720-008-A | Functional Test of the Sense Line Connected between the HP Bleed Valve and the Bleed-Pressure Regulator Valve with the Bleed Test Set P/N 99127B03 |
| TASK 36-11-00-720-008-A-01 | Functional Test of the Sense Line between the HP Bleed Valve and the Bleed- Pressure Regulator Valve with the Test Set P/N 98L36103002000 and P/N SBE2213 |
| TASK 36-11-49-000-018-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-000-029-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-000-820-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-018-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-029-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-820-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-51-000-010-A | Removal of the HP Bleed Valve |
| TASK 36-11-51-000-040-A | Removal of the High Pressure Bleed Valve |
| TASK 36-11-51-000-042-A | Removal of the High Pressure Bleed Valve |
| TASK 36-11-51-400-010-A | Installation of the HP Bleed Valve |
| TASK 36-11-51-400-040-A | Installation of the High-Pressure Bleed Valve |
| TASK 36-11-51-400-042-A | Installation of the High-Pressure Bleed Valve |
| TASK 36-11-57-000-001-A | Removal of the High Pressure (HP) Bleed Valve Closure Control Solenoid |
| TASK 36-11-57-400-001-A | Installation of the High Pressure (HP) Bleed-Valve Closure Control-Solenoid |
| TASK 36-11-58-000-001-A | Removal of the HP-Bleed Override Solenoid |
| TASK 36-11-58-400-001-A | Installation of the HP-Bleed Override Solenoid |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-00-861-138-B ** ON A/C NOT FOR ALL Subtask 36-11-00-941-140-B ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-010-171-E ** ON A/C NOT FOR ALL (1) Make sure that engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is pushed (the OFF legend is off).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-114-E ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
D. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-172-E ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). E. Get Access
(1) Open the left thrust reverser door (Ref. AMM TASK 78-36-00-010-040).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-171-G ** ON A/C NOT FOR ALL (1) Open the left thrust reverser door (Ref. AMM TASK 78-36-00-010-040).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
F. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-114-G ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
G. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-172-G ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). H. Get Access
(1) Open the left thrust reverser half (Ref. AMM TASK 78-32-00-010-010).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-171-J ** ON A/C NOT FOR ALL (1) Open the left thrust reverser half (Ref. AMM TASK 78-32-00-010-010).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
I. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-114-J ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
J. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-172-J ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). K. Get Access
(1) Open the left thrust reverser door (Ref. AMM TASK 78-36-00-010-040).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-480-111-A ** ON A/C NOT FOR ALL (1) Open the left thrust reverser door (Ref. AMM TASK 78-36-00-010-040).
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
L. Installation of the Tool for the Minimum Opening Pressure Test of the HPV (4000HA)
Connection of the Universal Test Port Tool (Red Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL
Connection of the Universal Test Port Tool (Blue Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL
(2) Remove the blanking cap from the test port.
(3) Connection of the M82000879 TEST PORT UNIVERSAL:
1 If you can install the red side of the tool:
a Remove the blue blanking cap from the blue side of the M82000879 TEST PORT UNIVERSAL .
b Install the blue blanking cap on the red side of the M82000879 TEST PORT UNIVERSAL .
c Tighten the blue blanking cap with your hand.
d Install the blue side of the M82000879 TEST PORT UNIVERSAL on the test port of the HPV.
e Tighten the M82000879 TEST PORT UNIVERSAL on the HPV with your hand.
(4) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED.
(6) Connection of the 98L36103002000 TEST SET - ENGINE BLEED:
(7) Set back to zero the digital pressure gage.
Subtask 36-11-00-720-094-A ** ON A/C NOT FOR ALL
Connection of the Universal Test Port Tool (Red Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL
Connection of the Universal Test Port Tool (Blue Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Cut, remove and discard the lockwire between the blanking cap and the test port of the HPV. (2) Remove the blanking cap from the test port.
(3) Connection of the M82000879 TEST PORT UNIVERSAL:
CAUTION:
ALWAYS TRY TO INSTALL THE RED SIDE OF THE UNIVERSAL TEST PORT TOOL FIRST. IF YOU CANNOT INSTALL THE RED SIDE, INSTALL THE BLUE SIDE.
(a) Install the red side of the M82000879 TEST PORT UNIVERSAL on the test port of the HPV: 1 If you can install the red side of the tool:
- Make sure that the blue blanking cap of the M82000879 TEST PORT UNIVERSAL is correctly tightened on the blue port.
a Remove the blue blanking cap from the blue side of the M82000879 TEST PORT UNIVERSAL .
b Install the blue blanking cap on the red side of the M82000879 TEST PORT UNIVERSAL .
c Tighten the blue blanking cap with your hand.
d Install the blue side of the M82000879 TEST PORT UNIVERSAL on the test port of the HPV.
e Tighten the M82000879 TEST PORT UNIVERSAL on the HPV with your hand.
(4) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED.
WARNING:
MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
(5) Connect an AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY to the 98L36103002000 TEST SET - ENGINE BLEED. (6) Connection of the 98L36103002000 TEST SET - ENGINE BLEED:
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(a) Connect the 98L36103002000 TEST SET - ENGINE BLEED with the short bend flexible assembly to the M82000879 TEST PORT UNIVERSAL . (7) Set back to zero the digital pressure gage.
M. Minimum Opening Pressure Test of the HPV (4000HA) with the Bleed Test Set P/N 98L36103002000 and the Universal Test Port Tool P/N M82000879
(1) Do the test:
(a) For HPV standard 6773B and 6713D (Deactivation screw is on the right of the test port, on the valve body).
(b) For HPV standard 6773E (Deactivation screw is on the left of the test port, on the regulator).
(c) For HPV standard 6773F and 6773G (Deactivation screw is on the left of the test port, on the regulator).
Subtask 36-11-00-480-112-A ** ON A/C NOT FOR ALL (1) Do the test:
(a) For HPV standard 6773B and 6713D (Deactivation screw is on the right of the test port, on the valve body).
| ACTION | RESULT |
|---|---|
1.On the 98L36103002000 TEST SET - ENGINE BLEED:
| |
2.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the 98L36103002000 TEST SET - ENGINE BLEED:
|
3.On the 98L36103002000 TEST SET - ENGINE BLEED:
| |
| ACTION | RESULT |
|---|---|
1.On the 98L36103002000 TEST SET - ENGINE BLEED:
| |
2.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the 98L36103002000 TEST SET - ENGINE BLEED:
|
3.On the 98L36103002000 TEST SET - ENGINE BLEED:
| |
| ACTION | RESULT |
|---|---|
1.On the 98L36103002000 TEST SET - ENGINE BLEED:
| |
2.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the 98L36103002000 TEST SET - ENGINE BLEED:
|
3.On the 98L36103002000 TEST SET - ENGINE BLEED:
| |
N. Installation of the Tool for the Opening/Closing Test of the HPV (4000HA)
(1) Install the tool for the minimum opening pressure test.
Subtask 36-11-00-720-095-A ** ON A/C NOT FOR ALL (1) Install the tool for the minimum opening pressure test.
NOTE: The opening/closing command will be simulated through the test bleed P/B on the Air Conditioning Panel 30VU.
O. Opening/Closing Test of the HPV (4000HA) with the Bleed Test Set P/N 98L36103002000 and the Universal Test Port Tool (M82000879)
(1) Install the tool for the opening/closing test.
(2) Do the test:
(b) Test set of the HPV (4000HA) with the M82000879 TEST PORT UNIVERSAL (blue side).
Subtask 36-11-00-480-113-B ** ON A/C NOT FOR ALL (1) Install the tool for the opening/closing test.
(2) Do the test:
NOTE: Two persons are necessary to do the opening/closing test.
(a) Test of the HPV (4000HA) with the M82000879 TEST PORT UNIVERSAL (red side). | ACTION | RESULT |
|---|---|
| 1.Open the shutoff valve of the air cylinder. | |
| 2.Use the primary regulator valve (on the test set or on the air cylinder) to pressurize the 98L36103002000 TEST SET - ENGINE BLEED to 100 psi (6.89 bar). | |
3.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the 98L36103002000 TEST SET - ENGINE BLEED:
|
4.On the overhead panel 30VU:
| On the overhead panel 30VU:
|
5.On the chronometer:
| On the chronometer:
|
6.On the overhead panel 30VU:
| On the overhead panel:
|
7.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the HPV:
|
| ACTION | RESULT |
|---|---|
| 1.Open the shutoff valve of the air cylinder. | |
| 2.Use the primary regulator valve (on the test set or on the air cylinder) to pressurize the test set to 100 psi (6.89 bar). | |
3.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the 98L36103002000 TEST SET - ENGINE BLEED:
|
4.On the overhead panel 30VU:
| On the overhead panel 30VU:
|
| | On the HPV:
|
5.On the chronometer:
| On the chronometer:
|
6.On the overhead panel 30VU:
| On the overhead panel:
|
7.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the HPV:
|
P. Installation of the Tool for the Test of the HPV Solenoid Valve
(1) For HPV with the deactivation screw on the regulator.
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(a) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
(d) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(e) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(f) Removal of the deactivation screw lockwire:
(g) Remove the deactivation screw.
3 Make sure the valve 1 and valve 2 are in the open position (valves aligned with the pneumatic ducts).
(i) Set back to zero GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
(k) Use the primary regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01) or AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to pressurize the 98L36103002000 TEST SET - ENGINE BLEED to 30 psi (2.0684 bar).
(2) For HPV without the deactivation screw on the regulator.
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(a) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
(d) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(e) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(f) Disconnection of the sense line:
2 Disconnect the sense line from the HPV.
(g) Connection of the sense line adaptor (T04):
2 TORQUE the sense line adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
3 Connect the sense line tester (T01) to the sense line adaptor (T04) with the hose (T05).
(h) Make sure that valve 1 and valve 2 are in the open position (valves are aligned with the pneumatic ducts).
(i) Set back to zero the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
(k) Use the primary regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01) or AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to pressurize the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to 30 psi (2.0684 bar).
Subtask 36-11-00-720-097-B ** ON A/C NOT FOR ALL (1) For HPV with the deactivation screw on the regulator.
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
(b) Connect the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to the 98L36103002000 TEST SET - ENGINE BLEED (Z01). NOTE: If the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) has a regulator valve, is not necessary to install the primary regulator valve that supplies the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
(c) Connection of the 98L36103002000 TEST SET - ENGINE BLEED (Z01): CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
1 Connect the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02). (d) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(e) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (f) Removal of the deactivation screw lockwire:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
1 Cut, remove and discard the lockwire from the deactivation screw of the HPV. (g) Remove the deactivation screw.
NOTE: Use a WRENCH 5/16 IN (8MM) - SPANNER if necessary.
(h) Connection of the sense line tester (T01) to the HPV: CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T02). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T03). MAKE SURE THAT THE ADAPTOR (T02 OR T03) IS CORRECTLY HAND TIGHTENED.
1 Connect the sense line tester (T01) to the HPV with the adaptor (T02) or (T03). CAUTION:
MAKE SURE THAT THE ADAPTOR (T02 OR T03) IS CORRECTLY HAND TIGHTENED.
2 Apply force when you tighten the adaptor (T02) or (T03) with your hand. 3 Make sure the valve 1 and valve 2 are in the open position (valves aligned with the pneumatic ducts).
(i) Set back to zero GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
NOTE: The pressure value shown on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY must be equal to 0 psi (0.0000 bar).
(j) Open the shutoff valve on the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03). (k) Use the primary regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01) or AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to pressurize the 98L36103002000 TEST SET - ENGINE BLEED to 30 psi (2.0684 bar).
(2) For HPV without the deactivation screw on the regulator.
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
(b) Connect the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to the 98L36103002000 TEST SET - ENGINE BLEED (Z01). NOTE: If the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) has a regulator valve, is not necessary to install the primary regulator valve that supplies the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
(c) Connection of the 98L36103002000 TEST SET - ENGINE BLEED (Z01). CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
1 Connect the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02). (d) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(e) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (f) Disconnection of the sense line:
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
1 Loosen the pneumatic union a quarter turn with a WRENCH 5/16 IN (8MM) - SPANNER. 2 Disconnect the sense line from the HPV.
NOTE: You must shake the sense line with your hand to prevent cross thread damage to the pneumatic union. To prevent damage to the fitting end of the sense line, turn the union with your hand and not with the WRENCH 5/16 IN (8MM) - SPANNER.
3 Put a PLUG - BLANKING on the HPV. (g) Connection of the sense line adaptor (T04):
CAUTION:
MAKE SURE THE ADAPTOR (T04) IS CORRECTLY TIGHTENED ON THE SENSE LINE.
1 Connect the sense line adaptor (T04) to the sense line union. 2 TORQUE the sense line adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. 3 Connect the sense line tester (T01) to the sense line adaptor (T04) with the hose (T05).
(h) Make sure that valve 1 and valve 2 are in the open position (valves are aligned with the pneumatic ducts).
(i) Set back to zero the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
NOTE: The pressure value shown on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY must be equal to 0 psi (0.0000 bar).
(j) Open the shutoff valve of the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03). (k) Use the primary regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01) or AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to pressurize the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to 30 psi (2.0684 bar).
Q. Functional Test of the HPV Solenoid Valve
(1) Install the tools for the functional test of the HPV Solenoid Valve.
(2) Do the test that follows:
4. Procedure(1) Install the tools for the functional test of the HPV Solenoid Valve.
(2) Do the test that follows:
| ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the 98L36103002000 TEST SET - ENGINE BLEED:
| On the 98L36103002000 TEST SET - ENGINE BLEED:
|
3.On the HPV solenoid valve:
| On the HPV solenoid valve:
|
4.On the 98L36103002000 TEST SET - ENGINE BLEED.
| |
Subtask 36-11-00-720-098-F ** ON A/C NOT FOR ALL
A. Health Check Procedure for the Pressure Control Function with Solenoid Installed
Subtask 36-11-00-720-098-G ** ON A/C NOT FOR ALL - Do the minimum opening pressure-test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-029) and (Ref. AMM TASK 36-11-49-400-029).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the functional test of the HPV solenoid valve.
- Replace the HPV solenoid valve (Ref. AMM TASK 36-11-58-000-001) and (Ref. AMM TASK 36-11-58-400-001).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- If there is a leak:
* Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph. - If there is no leak:
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-040) and (Ref. AMM TASK 36-11-51-400-040).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
A. Health Check Procedure for the Pressure Control Function with Solenoid Installed
Subtask 36-11-00-720-099-D ** ON A/C NOT FOR ALL - Do the minimum opening pressure-test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-018) and (Ref. AMM TASK 36-11-49-400-018).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the functional test of the HPV solenoid valve.
- Replace the HPV solenoid valve (Ref. AMM TASK 36-11-57-000-001) and (Ref. AMM TASK 36-11-57-400-001).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- If there is a leak:
* Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph. - If there is no leak:
* Do the minimum opening pressure-test.
* Do the opening/closing test.
* Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
B. Health Check Procedure for the Pressure Control Function without Solenoid Installed
Subtask 36-11-00-720-099-F ** ON A/C NOT FOR ALL - Do the minimum opening pressure test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-042) and (Ref. AMM TASK 36-11-51-400-042).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-042) and (Ref. AMM TASK 36-11-51-400-042).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-820) (Ref. AMM TASK 36-11-49-400-820).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-042) and (Ref. AMM TASK 36-11-51-400-042).
- Do these tests:
* The minimum opening pressure-test
* The opening/closing test. - Do the steps given in the Close-up paragraph.
B. Health Check Procedure for the Pressure Control Function without Solenoid Installed
5. Close-up- Do the minimum opening pressure-test of the HPV.
- Do the opening/closing test of the HPV.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Repair or replace the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-49-000-018) and (Ref. AMM TASK 36-11-49-400-018).
- Do the leak test of the sense line between the PRV and the HPV (Ref. AMM TASK 36-11-00-720-008).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
- Replace the HPV (Ref. AMM TASK 36-11-51-000-010) and (Ref. AMM TASK 36-11-51-400-010).
- Do the minimum opening pressure-test.
- Do the opening/closing test.
- Do the steps given in the Close-up paragraph.
Subtask 36-11-00-080-098-B ** ON A/C NOT FOR ALL
A. Removal of the Tool for the HPV SOLENOID VALVE
(1) HP Bleed Valve with the Deactivation Screw on the Regulator.
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(b) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
2 Install the deactivation screw on the HP bleed valve.
3 TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(2) HP Bleed Valve without the Deactivation Screw on the Regulator.
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(b) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
2 Connect the sense line to the HP bleed valve.
3 TORQUE the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
.
a Use the double torque method:
Subtask 36-11-00-080-100-A ** ON A/C NOT FOR ALL (1) HP Bleed Valve with the Deactivation Screw on the Regulator.
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(a) Disconnect the adaptor (T02) or (T03) from the HP bleed valve. (b) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(c) Installation of the deactivation screw: NOTE: If the adaptor (T03) is installed, the deactivation screw is equipped with a preformed PACKING.
1 Make sure that you install a new preformed packing on the deactivation screw if you have removed the adaptor (T03). 2 Install the deactivation screw on the HP bleed valve.
3 TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
4 Safety the deactivation screw on its support with (2) HP Bleed Valve without the Deactivation Screw on the Regulator.
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(a) Disconnect the adaptor (T04) from the sense line. (b) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
CAUTION:
TO PREVENT DAMAGE TO THE FITTING END OF THE SENSE LINE, TURN THE UNION WITH YOUR HAND AND NOT WITH A SPANNER.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(c) Connection of the sense line: NOTE: There must be no grease or oil on the pneumatic and sense line unions.
1 Remove the PLUG - BLANKING from the HP bleed valve. 2 Connect the sense line to the HP bleed valve.
3 TORQUE the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
. a Use the double torque method:
- Torque a first time the union of the sense line to the given value.
- Loosen the union of the sense line a quarter of a turn.
- Torque a second time the union to the given value.
B. Removal of the Tool for the Opening/Closing test and Minimum Opening Test
Connection of the Universal Test Port Tool (Blue Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL
Connection of the Universal Test Port Tool (Red Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL
(1) Close the shutoff valve of the air cylinder.
(2) Slowly open the purge valve to depressurize the 98L36103002000 TEST SET - ENGINE BLEED.
(3) Disconnection of the 98L36103002000 TEST SET - ENGINE BLEED from the test port:
(4) Disconnect the M82000879 TEST PORT UNIVERSAL from the test port of the HP bleed valve.
(5) Disconnect the air cylinder from the 98L36103002000 TEST SET - ENGINE BLEED.
(6) Install the blanking cap on the test port of the HP bleed valve.
(7) TORQUE the blanking cap to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(9) If the blue blanking cap was removed, install it on the M82000879 TEST PORT UNIVERSAL and tighten it with your hand.
Subtask 36-11-00-410-161-E ** ON A/C NOT FOR ALL
Connection of the Universal Test Port Tool (Blue Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL
Connection of the Universal Test Port Tool (Red Side) with the Bleed Test Set P/N 98L36103002000 ** ON A/C NOT FOR ALL (2) Slowly open the purge valve to depressurize the 98L36103002000 TEST SET - ENGINE BLEED.
(3) Disconnection of the 98L36103002000 TEST SET - ENGINE BLEED from the test port:
WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(a) Disconnect the short bend flexible assembly from the M82000879 TEST PORT UNIVERSAL and from the 98L36103002000 TEST SET - ENGINE BLEED. (4) Disconnect the M82000879 TEST PORT UNIVERSAL from the test port of the HP bleed valve.
(5) Disconnect the air cylinder from the 98L36103002000 TEST SET - ENGINE BLEED.
(6) Install the blanking cap on the test port of the HP bleed valve.
(7) TORQUE the blanking cap to between 1.2 and 1 m.daN (106.19 and 88.50 lbf.in )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(8) Safety the blanking cap with (9) If the blue blanking cap was removed, install it on the M82000879 TEST PORT UNIVERSAL and tighten it with your hand.
C. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-102-G ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
D. Reactivation of the Thrust Reverser
(1) Make sure that the thrust reverser is serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-00-410-162-E ** ON A/C NOT FOR ALL (1) Make sure that the thrust reverser is serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
E. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-161-G ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
F. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-102-H ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
G. Reactivation of the Thrust Reverser
(1) Make sure that the thrust reverser is serviceable after maintenance (Ref. AMM TASK 78-30-00-440-012).
Subtask 36-11-00-410-162-G ** ON A/C NOT FOR ALL (1) Make sure that the thrust reverser is serviceable after maintenance (Ref. AMM TASK 78-30-00-440-012).
H. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-11-00-410-161-J ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
I. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-102-K ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL.
(b) FOR [1000EM2] (ENGINE-2)
461AL.
J. Reactivation of the Thrust Reverser
(1) Make sure that the thrust reverser is serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-00-410-162-J ** ON A/C NOT FOR ALL (1) Make sure that the thrust reverser is serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
K. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-862-122-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR.
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).