Health Check Procedure - Temperature Control Function
TASK 36-11-00-720-802-A
Health Check Procedure - Temperature Control Function
The Bleed Health Check procedure has a set of steps to do in order to check preventively the three primary functions of the EBAS. The initial recommended maintenance interval is every 20 months. However, as the ageing effects on EBAS equipment are linked to local parameters and operating environment, Airbus recommends to customize this interval based on operators own experience.
The temperature control function contains the Fan Air Valve (FAV) 9HA1 (9HA2), the FAV control thermostat 7170HM and the sense line that connects them.
The Bleed Health Check procedures contain a flow chart that should be used for guidance. This flow chart gives a visual idea of the procedure.
The operator can remove the components that have a drift, as given in the applicable flow chart, immediately or at the next maintenance unless there is an EWD message and the source of the CLASS1 failure is the component that has the drift. In this condition, you must refer to the MMEL/TSM for the aircraft dispatch.
The operator can remove the components that have a drift, as given in the applicable flow chart, immediately or at the next maintenance unless there is an EWD message and the source of the CLASS1 failure is the component that has the drift. In this condition, you must refer to the MMEL/TSM for the aircraft dispatch.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-106-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-110-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-720-070-B ** ON A/C NOT FOR ALL
Subtask 36-11-00-080-077-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:07:10 UTC
Health Check Procedure - Temperature Control Function
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
NOTE: In the health check procedures the electrical harness is in correct operating condition.
1. Reason for the JobThe Bleed Health Check procedure has a set of steps to do in order to check preventively the three primary functions of the EBAS. The initial recommended maintenance interval is every 20 months. However, as the ageing effects on EBAS equipment are linked to local parameters and operating environment, Airbus recommends to customize this interval based on operators own experience.
The temperature control function contains the Fan Air Valve (FAV) 9HA1 (9HA2), the FAV control thermostat 7170HM and the sense line that connects them.
The Bleed Health Check procedures contain a flow chart that should be used for guidance. This flow chart gives a visual idea of the procedure.
The operator can remove the components that have a drift, as given in the applicable flow chart, immediately or at the next maintenance unless there is an EWD message and the source of the CLASS1 failure is the component that has the drift. In this condition, you must refer to the MMEL/TSM for the aircraft dispatch.
The operator can remove the components that have a drift, as given in the applicable flow chart, immediately or at the next maintenance unless there is an EWD message and the source of the CLASS1 failure is the component that has the drift. In this condition, you must refer to the MMEL/TSM for the aircraft dispatch.
NOTE: You can use bleed test set P/N 99127B04 as an alternative to bleed test set P/N 99127B03.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | AIR SOURCE - REGULATED, FILTERED, DRY |
| No specific | 1 | SUPPLY - 28 VDC, ELECTRICAL |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH - SPANNER |
| No specific | Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 2.5 and 0.8 m.daN (221.24 and 70.80 lbf.in ) ![]() | |
| 99127-231 | 1 | TEST SET BLEED - KIT |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191MB | |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 36-11-00-720-012-A | Functional Test of the Sense Line Connected between the Fan-Air Valve Control-Thermostat and the Fan Air Valve (FAV) with the Bleed Test Set P/N 99127B03 |
| TASK 36-11-00-720-012-A-01 | Functional Test of the Sense Line Connected between the Fan-Air Valve Control-Thermostat and the Fan Air Valve (FAV) with 98L36103002000 and SBE2213 |
| TASK 36-11-43-000-001-A | Removal of the Fan-Air Valve Control-Thermostat |
| TASK 36-11-43-400-001-A | Installation of the Fan-Air Valve Control-Thermostat |
| TASK 36-11-49-000-018-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-000-029-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-000-820-A | Removal of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-018-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-029-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-49-400-820-A | Installation of the Pneumatic Sense Lines in the Pylon |
| TASK 36-11-54-000-001-A | Removal of the Fan Air Valve |
| TASK 36-11-54-400-001-A | Installation of the Fan Air Valve |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL | |
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL | |
Subtask 36-11-00-861-106-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-110-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-010-114-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is pushed (the OFF legend is off).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-079-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
D. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-115-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). E. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-010-114-B ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
F. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-079-B ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
G. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-115-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-012). H. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-010-114-C ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
I. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-079-C ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
J. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-115-C ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). K. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-480-086-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
L. Preparation for installation
(1) Do a visual inspection of the FAV to find the position of the following features in the FAV actuator: sense line connection, test port and deactivation screw.
(a) For FAV standard 6730A and 6730B
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Connection of the FAV standard 6730A and 6730B with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Subtask 36-11-00-480-079-A ** ON A/C NOT FOR ALL (1) Do a visual inspection of the FAV to find the position of the following features in the FAV actuator: sense line connection, test port and deactivation screw.
(a) For FAV standard 6730A and 6730B
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Connection of the FAV standard 6730A and 6730B with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL - The test port is close to the border of the FAV actuator.
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL - The test port is close to the center of the FAV actuator.
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL
Sense Line Connected between the FAV Control-Thermostat and the FAV - Location ** ON A/C NOT FOR ALL - The test port is close to the center of the FAV actuator.
M. Installation of the Tool
Connection of the FAV standard 6730A and 6730B with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(2) Remove the deactivation screw.
(b) Use your hand to tighten the adaptor.
(c) Connect the sense line tester (T10) to the adaptor (T15) or (T19).
(d) Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
(e) Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(5) Connect the 99127B03 BLEED TEST SET to a 28VDC power supply:
(a) Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an SUPPLY - 28 VDC, ELECTRICAL:
(a) Make sure that the 99127B03 BLEED TEST SET is electrically powered:
1 If the 28VDC is supplied through an external power supply, turn the power supply to ON.
2 Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
3 If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(7) Connect the FAV electrical connection to the 99127B03 BLEED TEST SET as follows:
(a) Disconnect the FAV electrical connector from the aircraft harness connector (9HA-A).
1 Make sure that the 28VDC electrical cord (T03) is connected to the connector (11) and the 99127B03 BLEED TEST SET is electrically powered with the 28VDC.
2 Connect the cable (T09) to the connector (29).
3 Tighten the screws of the connector (29).
4 Connect the cable (T09) to the electrical connector (9HA-A):
b Make sure that you do not connect the cable (T09) to the connector (12).
(c) Connect the electrical connector cable (T08) from the 99127B03 BLEED TEST SET connector (12) to the electrical connector of the FAV:
1 The light (15) automatically goes off.
(8) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through the item (1).
4. Procedure
Connection of the FAV standard 6730A and 6730B with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Cut and discard the lockwire of the deactivation screw of the FAV. (2) Remove the deactivation screw.
NOTE: You can use a WRENCH - SPANNER if necessary.
(3) Connect the 99127B03 BLEED TEST SET to the sense line tester (T10). NOTE: You can use the 99127-231 TEST SET BLEED - KIT to do this test.
(4) Connect the sense line tester as follows: CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
(a) Install the adaptor (T15) or (T19) to the deactivation screw port.(b) Use your hand to tighten the adaptor.
(c) Connect the sense line tester (T10) to the adaptor (T15) or (T19).
(d) Connect the sense line tester (T10) with the hose (T05) to the bleed test-set connector (14).
(e) Connect the sense line tester (T10) with the hose (T04) to the bleed test-set connector (9).
(5) Connect the 99127B03 BLEED TEST SET to a 28VDC power supply:
(a) Connect the 28VDC electrical cord (T03) to the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an SUPPLY - 28 VDC, ELECTRICAL:
- Start the SUPPLY - 28 VDC, ELECTRICAL.
- Push the pushbutton (26) and make sure that the lights (15 to 21) come ON.
(a) Make sure that the 99127B03 BLEED TEST SET is electrically powered:
1 If the 28VDC is supplied through an external power supply, turn the power supply to ON.
2 Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0.00 bar).
3 If it is not equal to 0 psi (0.00 bar), push the ON button for 10 seconds.
(7) Connect the FAV electrical connection to the 99127B03 BLEED TEST SET as follows:
(a) Disconnect the FAV electrical connector from the aircraft harness connector (9HA-A).
CAUTION:
WHEN YOU CONNECT THE BLEED TEST SET, STRICTLY OBEY THE CONNECTION SEQUENCE GIVEN. IF YOU DO NOT, DAMAGE TO THE BLEED TEST SET CAN OCCUR.
(b) Connect the electrical connector cable (T09) from the 99127B03 BLEED TEST SET (29) to the electrical connector (9HA-A) in the aircraft harness: 1 Make sure that the 28VDC electrical cord (T03) is connected to the connector (11) and the 99127B03 BLEED TEST SET is electrically powered with the 28VDC.
2 Connect the cable (T09) to the connector (29).
3 Tighten the screws of the connector (29).
4 Connect the cable (T09) to the electrical connector (9HA-A):
NOTE: Usually, the bleed test-set light (17) comes on while you do the test of the FAV (9HA).
a The cable (T08) must not be connected to the connector (12) at this point. b Make sure that you do not connect the cable (T09) to the connector (12).
(c) Connect the electrical connector cable (T08) from the 99127B03 BLEED TEST SET connector (12) to the electrical connector of the FAV:
1 The light (15) automatically goes off.
(8) Use a AIR SOURCE - REGULATED, FILTERED, DRY to supply air pressure through the item (1).
Subtask 36-11-00-720-070-B ** ON A/C NOT FOR ALL
A. Health Check Test of the Temperature Control Function
(1) Do the minimum opening pressure-test of the FAV with the Bleed Test Set PN 99127B03.
1 Make sure that the two valves (1) and (2) are closed in the sense line tester (T10).
2 Make sure that the two valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
3 Open the main pressure-source shutoff valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
(b) If the minimum opening pressure-test of the FAV is correct:
1 Do the functional test of the sense line connected between the FAV control thermostat and the FAV with the Bleed Test Set PN 99127B03 (Ref. AMM TASK 36-11-00-720-012).
a If there is no leak:
Subtask 36-11-00-720-070-D ** ON A/C NOT FOR ALL (1) Do the minimum opening pressure-test of the FAV with the Bleed Test Set PN 99127B03.
WARNING:
BE CAREFUL WHEN YOU PRESSURIZE THE BLEED TEST SET. THE MAXIMUM PRESSURE PERMITTED BY THE BLEED TEST SET IS 290 PSI. PRESSURE HIGHER THAN THE PRESSURE PERMITTED BY THE EQUIPMENT CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(a) Pressurize the 99127B03 BLEED TEST SET: 1 Make sure that the two valves (1) and (2) are closed in the sense line tester (T10).
2 Make sure that the two valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
3 Open the main pressure-source shutoff valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
| ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
4.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
5.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
- Do the steps given in the Close-up paragraph.
1 Do the functional test of the sense line connected between the FAV control thermostat and the FAV with the Bleed Test Set PN 99127B03 (Ref. AMM TASK 36-11-00-720-012).
a If there is no leak:
- Replace the FAV (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
- Do the minimum opening pressure-test of the FAV.
- Do the steps given in the Close-up paragraph.
- Do a check of the unions and clamps of the sense line between the FAV control thermostat and the FAV.
* If the unions are loose:
** TORQUE the unions to between 2.5 and 0.8 m.daN (221.24 and 70.80 lbf.in )
.
* If the unions are correctly tightened:
** Replace the pneumatic sense line connected between the FAV control thermostat and the FAV (Ref. AMM TASK 36-11-49-000-029) and (Ref. AMM TASK 36-11-49-400-029). - Do the minimum opening pressure-test of the FAV.
* If the test of the FAV is correct:
** Do the steps given in the Close-up paragraph.
* If the test of the FAV is not correct:
** Replace the FAV control thermostat (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).
** Do the minimum opening pressure-test of the FAV.
A. Health Check Test of the Temperature Control Function
(1) Do the minimum opening pressure-test of the FAV with the Bleed Test Set PN 99127B03.
1 Make sure that the two valves (1) and (2) are closed in the sense line tester (T10).
2 Make sure that the two valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
3 Open the main pressure-source shutoff valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
(b) If the minimum opening pressure-test of the FAV is correct:
1 Do the functional test of the sense line connected between the FAV control thermostat and the FAV with the Bleed Test Set PN 99127B03 (Ref. AMM TASK 36-11-00-720-012).
a If there is no leak:
Subtask 36-11-00-720-070-E ** ON A/C NOT FOR ALL (1) Do the minimum opening pressure-test of the FAV with the Bleed Test Set PN 99127B03.
WARNING:
BE CAREFUL WHEN YOU PRESSURIZE THE BLEED TEST SET. THE MAXIMUM PRESSURE PERMITTED BY THE BLEED TEST SET IS 290 PSI. PRESSURE HIGHER THAN THE PRESSURE PERMITTED BY THE EQUIPMENT CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(a) Pressurize the 99127B03 BLEED TEST SET: 1 Make sure that the two valves (1) and (2) are closed in the sense line tester (T10).
2 Make sure that the two valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
3 Open the main pressure-source shutoff valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
| ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
4.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
5.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
- Do the steps given in the Close-up paragraph.
1 Do the functional test of the sense line connected between the FAV control thermostat and the FAV with the Bleed Test Set PN 99127B03 (Ref. AMM TASK 36-11-00-720-012).
a If there is no leak:
- Replace the FAV (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
- Do the minimum opening pressure-test of the FAV.
- Do the steps given in the Close-up paragraph.
- Do a check of the unions and clamps of the sense line between the FAV control thermostat and the FAV.
* If the unions are loose:
** TORQUE the unions to between 2.5 and 0.8 m.daN (221.24 and 70.80 lbf.in )
.
* If the unions are correctly tightened:
** Replace the pneumatic sense line connected between the FAV control thermostat and the FAV (Ref. AMM TASK 36-11-49-000-820) and (Ref. AMM TASK 36-11-49-400-820). - Do the minimum opening pressure-test of the FAV.
* If the test of the FAV is correct:
** Do the steps given in the Close-up paragraph.
* If the test of the FAV is not correct:
** Replace the FAV control thermostat (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).
** Do the minimum opening pressure-test of the FAV.
A. Health Check Test of the Temperature Control Function
(1) Do the minimum opening pressure-test of the FAV with the Bleed Test Set PN 99127B03.
1 Make sure that the two valves (1) and (2) are closed in the sense line tester (T10).
2 Make sure that the two valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
3 Open the main pressure-source shutoff valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
(b) If the minimum opening pressure-test of the FAV is correct:
1 Do the functional test of the sense line connected between the FAV control thermostat and the FAV with the Bleed Test Set PN 99127B03 (Ref. AMM TASK 36-11-00-720-012).
a If there is no leak:
5. Close-up(1) Do the minimum opening pressure-test of the FAV with the Bleed Test Set PN 99127B03.
WARNING:
BE CAREFUL WHEN YOU PRESSURIZE THE BLEED TEST SET. THE MAXIMUM PRESSURE PERMITTED BY THE BLEED TEST SET IS 290 PSI. PRESSURE HIGHER THAN THE PRESSURE PERMITTED BY THE EQUIPMENT CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
(a) Pressurize the 99127B03 BLEED TEST SET: 1 Make sure that the two valves (1) and (2) are closed in the sense line tester (T10).
2 Make sure that the two valves (6) and (7) are closed in the 99127B03 BLEED TEST SET.
3 Open the main pressure-source shutoff valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
| ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the 99127B03 BLEED TEST SET:
| |
3.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
4.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
5.On the 99127B03 BLEED TEST SET:
| On the 99127B03 BLEED TEST SET:
|
- Do the steps given in the Close-up paragraph.
1 Do the functional test of the sense line connected between the FAV control thermostat and the FAV with the Bleed Test Set PN 99127B03 (Ref. AMM TASK 36-11-00-720-012).
a If there is no leak:
- Replace the FAV (Ref. AMM TASK 36-11-54-000-001) and (Ref. AMM TASK 36-11-54-400-001).
- Do the minimum opening pressure-test of the FAV.
- Do the steps given in the Close-up paragraph.
- Do a check of the unions and clamps of the sense line between the FAV control thermostat and the FAV.
* If the unions are loose:
** TORQUE the unions to between 2.5 and 0.8 m.daN (221.24 and 70.80 lbf.in )
.
* If the unions are correctly tightened:
** Replace the pneumatic sense line connected between the FAV control thermostat and the FAV (Ref. AMM TASK 36-11-49-000-018) and (Ref. AMM TASK 36-11-49-400-018). - Do the minimum opening pressure-test of the FAV.
* If the test of the FAV is correct:
** Do the steps given in the Close-up paragraph.
* If the test of the FAV is not correct:
** Replace the FAV control thermostat (Ref. AMM TASK 36-11-43-000-001) and (Ref. AMM TASK 36-11-43-400-001).
** Do the minimum opening pressure-test of the FAV.
Subtask 36-11-00-080-077-A ** ON A/C NOT FOR ALL
A. Removal of the Tool
Connection of the FAV standard 6730A and 6730B with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(1) Close and disconnect the main pressure source.
(2) Open the pressure gauge A (3) to decrease the pressure to 0 psi.
(3) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(5) Disconnect and removal of the FAV electrical connection to the 99127B03 BLEED TEST SET:
(7) Disconnect the hose (T05) from the bleed-test set connector (14) and the sense line tester (T10).
(8) Disconnect the sense line tester (T10) from the adaptor (T15) or (T19).
(9) Disconnect the adaptor (T15) or (T19) from the deactivation screw port.
(b) Install the deactivation screw on the FAV.
(c) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
and.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
Subtask 36-11-00-410-113-A ** ON A/C NOT FOR ALL
Connection of the FAV standard 6730A and 6730B with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL (2) Open the pressure gauge A (3) to decrease the pressure to 0 psi.
(3) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(5) Disconnect and removal of the FAV electrical connection to the 99127B03 BLEED TEST SET:
- Disconnect the electrical connector cable (T08) between the 99127B03 BLEED TEST SET (12) and the electrical connector of the FAV.
- Disconnect the electrical connector cable (T09) from the electrical connector (9HA-A) in aircraft harness.
- Loosen the screws from connector (29).
- Disconnect the electrical connector cable (T09) from the 99127B03 BLEED TEST SET.
- Connect the FAV electrical connector from the Aircraft harness connector (9HA-A).
(7) Disconnect the hose (T05) from the bleed-test set connector (14) and the sense line tester (T10).
(8) Disconnect the sense line tester (T10) from the adaptor (T15) or (T19).
(9) Disconnect the adaptor (T15) or (T19) from the deactivation screw port.
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(10) Install the deactivation screw: NOTE: If the adaptor (T19) is installed, the deactivation screw has a preformed packing.
(a) Replace the preformed packing. (b) Install the deactivation screw on the FAV.
(c) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
and. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(d) Safety the deactivation screw on its support with B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-077-A ** ON A/C NOT FOR ALL Subtask 36-11-00-410-114-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
D. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-113-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
E. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-077-B ** ON A/C NOT FOR ALL Subtask 36-11-00-410-114-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
G. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-113-C ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
H. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-077-C ** ON A/C NOT FOR ALL Subtask 36-11-00-410-114-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
J. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-11-00-862-092-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).