Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid with the Bleed Test Set P/N 99127B03
TASK 36-11-00-720-010-A
Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid with the Bleed Test Set P/N 99127B03
To make sure that there are no leaks on the sense line Connected between the Pressure-Regulator Valve and the Pressure-Regulator Valve Control-Solenoid.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-087-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-100-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-480-055-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-410-092-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:07:01 UTC
Functional Test of the Sense Line between the Pressure Regulator Valve and the Pressure-Regulator Valve Control-Solenoid with the Bleed Test Set P/N 99127B03
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobTo make sure that there are no leaks on the sense line Connected between the Pressure-Regulator Valve and the Pressure-Regulator Valve Control-Solenoid.
NOTE: You can use bleed test set P/N 99127B04 as an alternative to bleed test set P/N 99127B03.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | SUPPLY - 28 VDC, ELECTRICAL |
| No specific | AR | WARNING NOTICE(S) |
| No specific | AR | WRENCH 5/16 IN (8MM) - SPANNER |
| No specific | Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) ![]() | |
| 99127-231 | 2 | TEST SET BLEED - KIT |
| 99127B03 | 2 | BLEED TEST SET |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191MB | |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-00-861-087-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-100-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-010-093-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is pushed (the OFF legend is off).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-067-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
D. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-094-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). E. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-010-093-B ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
F. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-067-B ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
G. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-094-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the Thrust-Reverser Hydraulic Control-Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). H. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-010-093-C ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
I. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-067-C ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
J. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-094-C ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). K. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-480-055-A ** ON A/C NOT FOR ALL
A. Installation of the Tool (Bleed-Pressure Regulator Valve with Deactivation Screw on Regulator)
(1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Connection of the Bleed-Pressure Regulator Valve (with Deactivation Screw on Regulator) with the Bleed test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(4) Remove the deactivation screw.
(b) Apply force when you tighten the adaptor (T15) or (T19) with your hand.
(6) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
Subtask 36-11-00-480-059-A ** ON A/C NOT FOR ALL (1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Connection of the Bleed-Pressure Regulator Valve (with Deactivation Screw on Regulator) with the Bleed test Set P/N 99127B03 ** ON A/C NOT FOR ALL NOTE: Use the 99127-231 TEST SET BLEED - KIT to do this test.
NOTE: Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0 bar). If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
(2) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL: - Start the SUPPLY - 28 VDC, ELECTRICAL.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut and discard the lockwire of the deactivation screw of the bleed-pressure regulator valve. (4) Remove the deactivation screw.
NOTE: Use a WRENCH 5/16 IN (8MM) - SPANNER if necessary.
(5) Connection of the sense line tester: CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
(a) Connect the sense line tester (T10) to the bleed-pressure regulator valve with the adaptor (T15) or (T19). (b) Apply force when you tighten the adaptor (T15) or (T19) with your hand.
(6) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
B. Installation of the Tool (Bleed-Pressure Regulator Valve without Deactivation Screw on Regulator)
(1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Connection of the Bleed-Pressure Regulator Valve (without Deactivation Screw on Regulator) with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(4) Remove the plug from the bleed-pressure regulator valve.
(5) Connection of the sense line tester:
(a) Connect the sense line tester (T10) to the bleed-pressure regulator valve with the adaptor (T25) and hose (T18).
(b) TORQUE the union of the adaptor (T25) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(6) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
Subtask 36-11-00-720-060-A ** ON A/C NOT FOR ALL (1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Connection of the Bleed-Pressure Regulator Valve (without Deactivation Screw on Regulator) with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL NOTE: Use the 99127-231 TEST SET BLEED - KIT to do this test.
NOTE: Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0 bar). If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
(2) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL: - Start the SUPPLY - 28 VDC, ELECTRICAL.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut and discard the lockwire of the plug of the bleed-pressure regulator valve. (4) Remove the plug from the bleed-pressure regulator valve.
(5) Connection of the sense line tester:
(a) Connect the sense line tester (T10) to the bleed-pressure regulator valve with the adaptor (T25) and hose (T18).
(b) TORQUE the union of the adaptor (T25) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (6) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
C. Test
Subtask 36-11-00-080-053-A ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the test set:
| |
3.On the test set:
| On the test set:
|
4.On the sense line tester:
| On the sense line tester:
|
5.On the test set:
| On the test set:
|
D. Removal of the Tool (Bleed-Pressure Regulator Valve with Deactivation Screw on Regulator)
Connection of the Bleed-Pressure Regulator Valve (with Deactivation Screw on Regulator) with the Bleed test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(1) With the pressure gauge A (3), decrease the pressure to 0 psi (0 bar).
(2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the adaptor (T15) or (T19), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the bleed-pressure regulator valve.
(b) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
.
(c) Safety the deactivation screw on its support with lockwire14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
Subtask 36-11-00-080-057-A ** ON A/C NOT FOR ALL
Connection of the Bleed-Pressure Regulator Valve (with Deactivation Screw on Regulator) with the Bleed test Set P/N 99127B03 ** ON A/C NOT FOR ALL (2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the adaptor (T15) or (T19), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the bleed-pressure regulator valve.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(5) Installation of the deactivation screw: NOTE: If the adaptor (T19) is installed, the deactivation screw is equipped with a preformed packing.
(a) Install the deactivation screw on the bleed-pressure regulator valve. (b) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. (c) Safety the deactivation screw on its support with lockwire
E. Removal of the Tool (Bleed-Pressure Regulator Valve without Deactivation Screw on Regulator)
Connection of the Bleed-Pressure Regulator Valve (without Deactivation Screw on Regulator) with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL
(1) With the pressure gauge A (3), decrease the pressure to 0 psi (0 bar).
(2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the adaptor (T25), the hose (T18), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the bleed-pressure regulator valve.
(5) Install the plug on the bleed-pressure regulator valve.
(6) Safety with lockwire:
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
5. Close-up
Connection of the Bleed-Pressure Regulator Valve (without Deactivation Screw on Regulator) with the Bleed Test Set P/N 99127B03 ** ON A/C NOT FOR ALL (2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the adaptor (T25), the hose (T18), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the bleed-pressure regulator valve.
(5) Install the plug on the bleed-pressure regulator valve.
(6) Safety with lockwire:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Safety the plug on its support with lockwire Subtask 36-11-00-410-092-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-067-A ** ON A/C NOT FOR ALL Subtask 36-11-00-410-093-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-092-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-067-B ** ON A/C NOT FOR ALL Subtask 36-11-00-410-093-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
F. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-11-00-410-092-C ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
G. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-067-C ** ON A/C NOT FOR ALL Subtask 36-11-00-410-093-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser doors (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
I. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-862-082-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).