W DOC AIRBUS | AMM A320F

Functional Test of the Sense Line Connected Upstream of the Bleed-Pressure Regulator Valve with the Test Set 98L36103002000 and Tester Kit SBE2213


TASK 36-11-00-720-009-A-01
Functional Test of the Sense Line Connected Upstream of the Bleed-Pressure Regulator Valve with the Test Set 98L36103002000 and Tester Kit SBE2213


WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4001HA ** ON A/C NOT FOR ALL
1. Reason for the Job
The source of this procedure is the Air Engine System Health Check User Manual.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
1
AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY
No specific
1
GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY
No specific
1
PLUG - BLANKING
No specific
AR
WARNING NOTICE(S)
No specific
1
WRENCH 5/16 IN (8MM) - SPANNER
No specific
Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) T
No specific
Torque wrench: range to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft ) T
98L36103002000
1
TEST SET - ENGINE BLEED
SBE2213
1
KIT TOOL-TESTER SENSE LINE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
191MB
FOR [1000EM1] (ENGINE-1)
437AL, 438AR, 451AL
FOR [1000EM2] (ENGINE-2)
447AL, 448AR, 461AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 71-13-00-010-010-A
Opening of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-010-040-B
Opening of the Fan Cowl Doors
TASK 71-13-00-410-010-A
Closing of the Fan Cowls 437AL(447AL),438AR(448AR)
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
TASK 71-13-00-410-040-B
Closing of the Fan Cowl Doors
TASK 78-30-00-040-012-A
Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance
TASK 78-30-00-081-041-A
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-081-041-B
Make the Thrust Reverser Serviceable after Maintenance
TASK 78-30-00-440-012-A
Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance
TASK 78-30-00-481-041-A
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-30-00-481-041-B
Make the Thrust Reverser Unserviceable for Maintenance
TASK 78-32-00-010-010-A
Opening of the Thrust Reverser Halves
TASK 78-32-00-410-010-A
Closing of the Thrust Reverser Halves
TASK 78-36-00-010-040-A
Opening of the Thrust Reverser Doors
TASK 78-36-00-010-040-B
Opening of the Thrust Reverser Doors
TASK 78-36-00-410-040-A
Closing of the Thrust Reverser Doors
TASK 78-36-00-410-040-B
Closing of the Thrust Reverser Doors
3. Job Set-up
Subtask 36-11-00-861-101-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-00-941-105-A ** ON A/C NOT FOR ALL
B. Safety Precautions
   (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
   (2) On the AIR COND panel 30VU:
  • Make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on).
  • Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
  • Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
   (3) On the ENG panel 115VU:
  • Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
   (4) On the HP ground connector:
  • Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
   (5) On the ENG section of the maintenance panel 50VU:
  • Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
  • Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 36-11-00-010-104-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Open the access door 191MB.
   (3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-072-A ** ON A/C NOT FOR ALL
D. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 36-11-00-010-105-A ** ON A/C NOT FOR ALL
E. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL
   (2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-104-B ** ON A/C NOT FOR ALL
F. Get Access
   (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Open the access door 191MB.
   (3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-072-B ** ON A/C NOT FOR ALL
G. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Do the deactivation of the Thrust-Reverser Hydraulic Control-Unit (HCU) (Ref. AMM TASK 78-30-00-040-012).
Subtask 36-11-00-010-105-B ** ON A/C NOT FOR ALL
H. Open the left thrust-reverser half (Ref. AMM TASK 78-32-00-010-010):
   (1) FOR [1000EM1] (ENGINE-1)
451AL
   (2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-104-C ** ON A/C NOT FOR ALL
I. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Open the access door 191MB.
   (3) Put ACCESS PLATFORM 1M(3 FT) the in position below the engine.
Subtask 36-11-00-040-072-C ** ON A/C NOT FOR ALL
J. Deactivation of the Thrust Reverser
WARNING: MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041).
Subtask 36-11-00-010-105-C ** ON A/C NOT FOR ALL
K. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
   (1) FOR [1000EM1] (ENGINE-1)
451AL
   (2) FOR [1000EM2] (ENGINE-2)
461AL.
4. Procedure
Subtask 36-11-00-480-062-A ** ON A/C NOT FOR ALL
A. Installation of the Tool
   (1) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
   (2) Connection of the test set.
WARNING: MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT. IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
CAUTION: BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT. THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
     (a) connect the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
   (3) Connect the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to the SBE2213 KIT TOOL-TESTER SENSE LINE.
   (4) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
   (5) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) T.
CAUTION: USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
   (6) Disconnection of the sense line:
NOTE: Loosen the pneumatic union a quarter turn with a WRENCH 5/16 IN (8MM) - SPANNER.Then shake the sense line with your hand to prevent cross thread damage to the pneumatic union. To prevent damage to the fitting end of the sense line, turn the union with your hand and not with the WRENCH 5/16 IN (8MM) - SPANNER.
     (a) Disconnect the sense line from the union of the tee-duct.
     (b) Put a PLUG - BLANKING on the tee-duct.
   (7) Connection of the sense line adaptor (T04):
CAUTION: MAKE SURE THE ADAPTOR (T04) IS CORRECTLY TIGHTENED ON THE SENSE LINE.
     (a) Connect the sense line adaptor (To4) to the sense line union and TORQUE to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
T.
     (b) Connect the sense line tester (T01) to the sense line adaptor (T04) with the hose (T05).
   (8) Make sure that valve 1 and valve 2 are in the open position (valves are aligned with the pneumatic ducts).
   (9) Do a reset of all GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
NOTE: The pressure value shown on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY must be equal to 0 psi (0.0000 bar).
   (10) Make sure that the regulator valve of the test set is closed before pressurize the system.
Subtask 36-11-00-720-065-A ** ON A/C NOT FOR ALL
CAUTION: DO NOT APPLY A PRESSURE OF MORE THAN 145 PSI (10 BAR). A HIGHER PRESSURE WILL CAUSE DAMAGE TO THE SENSE LINE.
B. Test
ACTION
RESULT
1.Pressurize the test set:
  • If there is a manometer on the air cylinder then installation of the primary regulator valve is not necessary. Use the air cylinder shut off valve and the manometer to slowly pressurize the test set to 100 psi (6.8948 bar).
  • If there is no manometer in the air cylinder then installation of primary regulator valve is mandatory. In this case the primary regulator valve will limit the pressure in the set to 217 psi (14.9616 bar).

2.On the test set (Z01):
  • Open the shutoff valve.

3.On the test set (Z01):
  • With the pressure regulator valve increase the pressure to 21.75 +0.75 psi or -0.75 psi (1.4996 +0.0517 bar or -0.0517 bar).
On the test set (Z01):
  • The pressure value shows on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1.
4.On the sense line tester (T01):
  • Close the valve 1.
On the sense line tester (T01):
  • The valve 1 is not aligned with the pneumatic duct.
5.On the sense line tester (T01):
  • Do a check of the pressure value shown on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2.
On the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2:
  • The pressure is more or equal to the input pressure value (with a tolerance of -0.2 psi (-0.0138 bar)).
6.On the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03):
  • Close the shutoff valve.

7.On the test set (Z01):
  • Slowly open the purge valve to depressurize the test set.

Subtask 36-11-00-080-060-A ** ON A/C NOT FOR ALL
C. Removal of the Tool
WARNING: BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT. THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
   (1) Make sure that the duct is not pressurized before removal of the tool.
   (2) Disconnect the adaptor (T04) from the sense line.
   (3) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
CAUTION: TO PREVENT DAMAGE TO THE FITTING END OF THE SENSE LINE, TURN THE UNION WITH YOUR HAND AND NOT WITH A SPANNER.
CAUTION: USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
   (4) Connection of the sense line:
NOTE: There must be no grease or oil on the pneumatic and sense line unions.
     (a) Remove the PLUG - BLANKING from the tee-duct.
     (b) Connect the sense line to the tee-duct.
     (c) Do the double torque method on the union of the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft ) T.
       1 Double torque method:
         a Torque a first time the union of the sense line to the given value.
         b Loosen the union of the sense line a quarter of a turn.
         c Torque a second time the union to the given value.
     (d) Make a mark on the union of the sense line with paint.
5. Close-up
Subtask 36-11-00-410-103-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-440-072-A ** ON A/C NOT FOR ALL
B. Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-00-410-104-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Close the access door 191MB.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-103-B ** ON A/C NOT FOR ALL
D. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
451AL
     (b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-072-B ** ON A/C NOT FOR ALL
E. Do the re-activation of the thrust reverser HCU (Ref. AMM TASK 78-30-00-440-012).
Subtask 36-11-00-410-104-B ** ON A/C NOT FOR ALL
F. Close Access
   (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Close the access door 191MB.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the access platform(s).
Subtask 36-11-00-410-103-C ** ON A/C NOT FOR ALL
G. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
451AL
     (b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-072-C ** ON A/C NOT FOR ALL
H. Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-081-041).
Subtask 36-11-00-410-104-C ** ON A/C NOT FOR ALL
I. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
   (2) Close the access door 191MB.
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-862-087-A ** ON A/C NOT FOR ALL
J. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 01:07:00 UTC