Functional Test of the Sense Line Connected between the HP Bleed Valve and the Bleed-Pressure Regulator Valve with the Bleed Test Set P/N 99127B03
TASK 36-11-00-720-008-A
Functional Test of the Sense Line Connected between the HP Bleed Valve and the Bleed-Pressure Regulator Valve with the Bleed Test Set P/N 99127B03
To make sure that there are no leaks on the sense line connected between the High-Pressure Bleed Valve and the Bleed-Pressure Regulator Valve.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-085-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-098-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-480-052-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-410-088-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:06:56 UTC
Functional Test of the Sense Line Connected between the HP Bleed Valve and the Bleed-Pressure Regulator Valve with the Bleed Test Set P/N 99127B03
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 4001HA ** ON A/C NOT FOR ALL
1. Reason for the JobTo make sure that there are no leaks on the sense line connected between the High-Pressure Bleed Valve and the Bleed-Pressure Regulator Valve.
NOTE: You can use bleed test set P/N 99127B04 as an alternative to bleed test set P/N 99127B03.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | PACKING |
| No specific | 1 | SUPPLY - 28 VDC, ELECTRICAL |
| No specific | AR | WARNING NOTICE(S) |
| No specific | AR | WRENCH 5/16 IN (8MM) - SPANNER |
| No specific | Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft ) ![]() | |
| 99127-231 | 1 | TEST SET BLEED - KIT |
| 99127B03 | 1 | BLEED TEST SET |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191MB | |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-00-861-085-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-098-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-010-089-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-065-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
D. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-090-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). E. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-089-B ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
F. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-065-B ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
G. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-090-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the Thrust-Reverser Hydraulic Control-Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). H. Open the left thrust-reverser half (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-089-C ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
I. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-065-C ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
J. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-090-C ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). K. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-480-052-A ** ON A/C NOT FOR ALL
A. Installation of the Tool (HP Bleed Valve with Deactivation Screw on Regulator)
(1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(4) Remove the deactivation screw.
(b) Apply force when you tighten the adaptor (T15) or (T19) with your hand.
(6) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
Subtask 36-11-00-480-053-A ** ON A/C NOT FOR ALL (1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL NOTE: Use the 99127-231 TEST SET BLEED - KIT to do this test.
NOTE: Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0 bar). If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
(2) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL: - Start the SUPPLY - 28 VDC, ELECTRICAL.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut and discard the lockwire of the deactivation screw of the HP bleed valve. (4) Remove the deactivation screw.
NOTE: Use a WRENCH 5/16 IN (8MM) - SPANNER if necessary.
(5) Connection of the sense line tester: CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T15). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T19). MAKE SURE THAT THE ADAPTOR (T15 OR T19) IS CORRECTLY TIGHTENED.
(a) Connect the sense line tester (T10) to the HP bleed valve with the adaptor (T15) or (T19). (b) Apply force when you tighten the adaptor (T15) or (T19) with your hand.
(6) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
B. Installation of the Tool (HP Bleed Valve without Deactivation Screw on Regulator)
(1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(4) Put the blanking plug (T16) on the HP bleed valve.
(5) Connection of the sense line adaptor (T20):
.
(6) Connect the sense line tester (T10) to the sense line adaptor (T20).
(7) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
Subtask 36-11-00-480-053-B ** ON A/C NOT FOR ALL (1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL NOTE: Use the 99127-231 TEST SET BLEED - KIT to do this test.
NOTE: Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0 bar). If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
(2) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL: - Start the SUPPLY - 28 VDC, ELECTRICAL.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(3) Disconnection of the sense line: NOTE: Loosen the pneumatic union a quarter turn with a spanner. Then shake the sense line with your hand to prevent cross thread damage to the pneumatic union.
To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
(a) Disconnect the sense line from the HP bleed valve. To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
(4) Put the blanking plug (T16) on the HP bleed valve.
(5) Connection of the sense line adaptor (T20):
CAUTION:
MAKE SURE THE ADAPTOR T20 IS CORRECTLY TIGHTENED ON THE SENSE LINE.
(a) Connect the sense line adaptor (T20) to the sense line union and TORQUE to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (6) Connect the sense line tester (T10) to the sense line adaptor (T20).
(7) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
B. Installation of the Tool (HP Bleed Valve without Deactivation Screw on Regulator)
(1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(4) Put the blanking plug (T16) on the HP bleed valve.
(5) Connection of the sense line adaptor (T20):
.
(6) Connect the sense line tester (T10) to the sense line adaptor (T20).
(7) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
Subtask 36-11-00-720-058-A ** ON A/C NOT FOR ALL (1) Connect the 99127B03 BLEED TEST SET (T01) to the sense line tester (T10) as shown in the figure.
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL NOTE: Use the 99127-231 TEST SET BLEED - KIT to do this test.
NOTE: Set the pressure gauge (5) to ON. The pressure value shown on the LCD screen must be equal to 0 psi (0 bar). If it is not equal to 0 psi (0 bar), push the ON button for 10 seconds.
(2) Connect the 28VDC electrical cord (T03) between the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and an external SUPPLY - 28 VDC, ELECTRICAL: - Start the SUPPLY - 28 VDC, ELECTRICAL.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(3) Disconnection of the sense line: NOTE: Loosen the pneumatic union a quarter turn with a spanner. Then shake the sense line with your hand to prevent cross thread damage to the pneumatic union.
To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
NOTE: Do not bend the pneumatic pipes or use force to get access. If necessary, release the supporting clips of the sense line until the sense line can be moved easily.
(a) Disconnect the sense line from the HP bleed valve. (4) Put the blanking plug (T16) on the HP bleed valve.
(5) Connection of the sense line adaptor (T20):
CAUTION:
MAKE SURE THE ADAPTOR T20 IS CORRECTLY TIGHTENED ON THE SENSE LINE.
(a) Connect the sense line adaptor (T20) to the sense line union and TORQUE to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (6) Connect the sense line tester (T10) to the sense line adaptor (T20).
(7) Open the pressure-source shut-off valve slowly and pressurize the 99127B03 BLEED TEST SET (T01) to 30 psi (2.07 bar).
C. Test
Subtask 36-11-00-080-050-A ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the sense line tester:
| On the sense line tester:
|
2.On the test set:
| |
3.On the test set:
| On the test set:
|
4.On the sense line tester:
| On the sense line tester:
|
5.On the test set:
| On the test set:
|
6.On the High Pressure (HP) bleed-valve control-solenoid (4029KS):
| |
D. Removal of the Tool (HP Bleed Valve with the Deactivation Screw on the Regulator)
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(1) With pressure gauge A (3), decrease the pressure to 0 psi (0 bar).
(2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the adaptor (T15) or (T19), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the HP bleed valve.
(b) Install the deactivation screw on the HP bleed valve.
(c) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
.
(d) Safety the deactivation screw on its support with the lockwire14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
Subtask 36-11-00-080-051-A ** ON A/C NOT FOR ALL
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL (2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the adaptor (T15) or (T19), the sense line tester (T10) and the 99127B03 BLEED TEST SET (T01) from the HP bleed valve.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(5) To install the deactivation screw, do the steps that follow: NOTE: If the adaptor (T19) is installed, the deactivation screw has a preformed PACKING.
(a) Make sure that you install a new preformed PACKING on the deactivation screw if you removed the adaptor (T19).(b) Install the deactivation screw on the HP bleed valve.
(c) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. (d) Safety the deactivation screw on its support with the lockwire
E. Removal of the Tool (HP Bleed Valve without Deactivation Screw on Regulator)
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(1) With the pressure gauge A (3), decrease the pressure to 0 psi (0 bar).
(2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the 99127B03 BLEED TEST SET (T01), the sense line tester (T10) and the sense line adaptor (T20) from the sense line union.
(5) Remove the blanking plug (T16) from the HP bleed valve.
.
5. Close-up
Functional Test of the Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL (2) Stop the SUPPLY - 28 VDC, ELECTRICAL.
(3) Disconnect the 28VDC electrical cord (T03) from the electrical inlet (11) of the 99127B03 BLEED TEST SET (T01) and the external SUPPLY - 28 VDC, ELECTRICAL.
(4) Disconnect and remove the 99127B03 BLEED TEST SET (T01), the sense line tester (T10) and the sense line adaptor (T20) from the sense line union.
(5) Remove the blanking plug (T16) from the HP bleed valve.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(6) Connection of the sense line: NOTE: There must be no grease or oil on the pneumatic and sense line unions.
(a) Connect the sense line to the HP bleed valve. NOTE: To prevent damage to the fitting end of the sense line, turn the union with your hand and not with a spanner.
(b) Do the double torque method on the union of the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
. NOTE: Double torque method: Torque a first time the union of the sense line to the given value. Loosen the union of the sense line a quarter of a turn. Then torque a second time the union to the given value.
(c) Make a mark on the union of the sense line with paint. Subtask 36-11-00-410-088-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-065-A ** ON A/C NOT FOR ALL Subtask 36-11-00-410-089-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-088-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-065-B ** ON A/C NOT FOR ALL Subtask 36-11-00-410-089-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
F. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-11-00-410-088-C ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
G. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-065-C ** ON A/C NOT FOR ALL Subtask 36-11-00-410-089-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
I. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-862-080-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).