Functional Test of the Sense Line between the HP Bleed Valve and the Bleed- Pressure Regulator Valve with the Test Set P/N 98L36103002000 and P/N SBE2213
TASK 36-11-00-720-008-A-01
Functional Test of the Sense Line between the HP Bleed Valve and the Bleed- Pressure Regulator Valve with the Test Set P/N 98L36103002000 and P/N SBE2213
The source of this procedure is the Air Engine Bleed System Health Check User Manual.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-100-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-104-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-480-060-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-080-058-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-410-101-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:06:57 UTC
Functional Test of the Sense Line between the HP Bleed Valve and the Bleed- Pressure Regulator Valve with the Test Set P/N 98L36103002000 and P/N SBE2213
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobThe source of this procedure is the Air Engine Bleed System Health Check User Manual.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY |
| No specific | 1 | GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY |
| No specific | AR | PACKING |
| No specific | 1 | PLUG - BLANKING |
| No specific | AR | WARNING NOTICE(S) |
| No specific | 1 | WRENCH 5/16 IN (8MM) - SPANNER |
| No specific | Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft ) ![]() | |
| 98L36103002000 | 1 | TEST SET - ENGINE BLEED |
| SBE2213 | 1 | KIT TOOL-TESTER SENSE LINE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 191MB | |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-00-861-100-A ** ON A/C NOT FOR ALL Subtask 36-11-00-941-104-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-010-102-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (the ON legend is off).
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
- Put a WARNING NOTICE(S) in position to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
C. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-071-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
D. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-103-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). E. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-102-B ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
F. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-071-B ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
G. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-103-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Do the deactivation of the Thrust-Reverser Hydraulic Control-Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). H. Open the left thrust-reverser half (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-102-C ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
I. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
Subtask 36-11-00-040-071-C ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Open the access door 191MB.
(3) Put the ACCESS PLATFORM 1M(3 FT) in position below the engine.
J. Deactivation of the Thrust Reverser
Subtask 36-11-00-010-103-C ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Make the thrust reverser unserviceable for maintenance (Ref. AMM TASK 78-30-00-481-041). K. Open the left thrust-reverser door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-480-060-A ** ON A/C NOT FOR ALL
A. Installation of the Tool (HP Bleed Valve with the Deactivation Screw on the Regulator)
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(1) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
(3) Connection of the test set.
(4) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(5) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(6) Removal of the deactivation screw lockwire:
(7) Remove the deactivation screw.
(c) Make sure the valve 1 and valve 2 are in the open position (valves aligned with the pneumatic ducts).
(9) Do a reset of GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY gauges 1 and 2.
Subtask 36-11-00-480-061-A ** ON A/C NOT FOR ALL
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
(2) Connect the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to the 98L36103002000 TEST SET - ENGINE BLEED (Z01). (3) Connection of the test set.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(a) Connect the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02). (4) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(5) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (6) Removal of the deactivation screw lockwire:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Cut and discard the lockwire of the deactivation screw of the HP bleed valve. (7) Remove the deactivation screw.
NOTE: Use a WRENCH 5/16 IN (8MM) - SPANNER if necessary.
(8) Connection of the sense line tester (T01) to the HP bleed valve: CAUTION:
FIRST TRY TO INSTALL THE ADAPTOR WITH THE SHORTEST THREADED AREA (T02). IF YOU CANNOT INSTALL IT, INSTALL THE OTHER ADAPTOR (T03). MAKE SURE THAT THE ADAPTOR (T02 OR T03) IS CORRECTLY HAND TIGHTENED.
(a) Connect the sense line tester (T01) to the HP bleed valve with the adaptor (T02) or (T03). CAUTION:
MAKE SURE THAT THE ADAPTOR (T02 OR T03) IS CORRECTLY HAND TIGHTENED.
(b) Apply force when you tighten the adaptor (T02) or (T03) with your hand. (c) Make sure the valve 1 and valve 2 are in the open position (valves aligned with the pneumatic ducts).
(9) Do a reset of GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY gauges 1 and 2.
NOTE: The pressure value shown on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY must be equal to 0 psi (0.0000 bar).
(10) Make sure that the regulator valve of the test set is closed before pressurize the system. B. Installation of the Tool (HP Bleed Valve without the Deactivation Screw on the Regulator)
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(1) Close the shutoff valve, the purge valve and the pressure regulator valve on the 98L36103002000 TEST SET - ENGINE BLEED (Z01).
(3) Connection of the test set.
(4) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(5) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
.
(b) Put a PLUG - BLANKING on the HP bleed valve.
(7) Connection of the sense line adaptor (T04):
.
(b) Connect the sense line tester (T01) to the sense line adaptor (T04) with the hose (T05).
(8) Make sure that the valve 1 and valve 2 are in the open position (valves are aligned with the pneumatic ducts).
(9) Do a reset of all GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
Subtask 36-11-00-720-064-A ** ON A/C NOT FOR ALL
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE PRESSURE SUPPLIED TO BLEED TEST SET 98L36103002000 NEVER EXCEEDS 217 PSI (15 BAR). IF THE PRESSURE SUPPLIED TO THE BLEED TEST SET EXCEEDS THIS VALUE, THERE IS A RISK OF INJURY TO PERSONNEL AND DAMAGE TO EQUIPMENT.
IF THE AIR CYLINDER DOES NOT HAVE A MANOMETER INSTALLED, YOU MUST INSTALL THE PRIMARY REGULATOR VALVE BETWEEN THE AIR BOTTLE AND BLEED TEST SET 98L36103002000. THE PRIMARY REGULATOR VALVE WILL LIMIT THE PRESSURE IN THE BLEED TEST SET TO 217 PSI (15 BAR).
(2) Connect the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) to the 98L36103002000 TEST SET - ENGINE BLEED (Z01). (3) Connection of the test set.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(a) Connect the 98L36103002000 TEST SET - ENGINE BLEED (Z01) to the SBE2213 KIT TOOL-TESTER SENSE LINE. (4) Connect the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2 to the valve 2 port of the sense line tester (T01) with the adaptor (T04).
(5) TORQUE the adaptor (T04) to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(6) Disconnection of the sense line: NOTE: Loosen the pneumatic union a quarter turn with a WRENCH 5/16 IN (8MM) - SPANNER. Then shake the sense line with your hand to prevent cross thread damage to the pneumatic union. To prevent damage to the fitting end of the sense line, turn the union with your hand and not with the WRENCH 5/16 IN (8MM) - SPANNER.
(a) Disconnect the sense line from the HP bleed valve. (b) Put a PLUG - BLANKING on the HP bleed valve.
(7) Connection of the sense line adaptor (T04):
CAUTION:
MAKE SURE THE ADAPTOR (T04) IS CORRECTLY TIGHTENED ON THE SENSE LINE.
(a) Connect the sense line adaptor (T04) to the sense line union and TORQUE to between 1.1 and 0.9 m.daN (97.35 and 79.65 lbf.in )
. (b) Connect the sense line tester (T01) to the sense line adaptor (T04) with the hose (T05).
(8) Make sure that the valve 1 and valve 2 are in the open position (valves are aligned with the pneumatic ducts).
(9) Do a reset of all GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 1 and 2.
NOTE: The pressure value shown on the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY must be equal to 0 psi (0.0000 bar).
(10) Make sure that the regulator valve of the test set is closed before pressurize the system. CAUTION:
DO NOT APPLY A PRESSURE OF MORE THAN 145 PSI (10 BAR). A HIGHER PRESSURE WILL CAUSE DAMAGE TO THE SENSE LINE.
C. Test | ACTION | RESULT |
|---|---|
1.Pressurize the test set:
| |
2.On the test set (Z01):
| |
3.On the test set (Z01):
| On the test set (Z01):
|
4.On the sense line tester (T01):
| On the sense line tester (T01):
|
5.On the sense line tester (T01):
| On the GAGE - ABSOLUTE PRESSURE, DIGITAL, 0.001 BAR ACCURACY 2:
|
6.On the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03):
| |
7.On the test set (Z01):
| |
D. Removal of the Tool (HP Bleed Valve with the Deactivation Screw on the Regulator)
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(2) Disconnect the adaptor (T02) or (T03) from the HP bleed valve.
(3) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), the 98L36103002000 TEST SET - ENGINE BLEED (Z01) and the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
(b) Install the deactivation screw on the HP bleed valve.
(c) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
.
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
Subtask 36-11-00-080-059-A ** ON A/C NOT FOR ALL
Functional Test of the Sense Line between the HP Bleed Valve (with the Deactivation Screw on the Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(1) Make sure that the duct is not pressurized before the removal of the tool. (2) Disconnect the adaptor (T02) or (T03) from the HP bleed valve.
(3) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), the 98L36103002000 TEST SET - ENGINE BLEED (Z01) and the AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
CAUTION:
WHEN YOU INSTALL THE DEACTIVATION SCREW ON THE VALVE, TIGHTEN THE SCREW WITH YOUR HAND BEFORE YOU TORQUE IT. IF YOU DO NOT OBEY THIS PRECAUTION, YOU CAN CAUSE DAMAGE TO THE SCREW AND THE VALVE.
CAUTION:
BEFORE YOU INSTALL THE DEACTIVATION SCREW, MAKE SURE THAT THE PREFORMED PACKING IS INSTALLED ON THE DEACTIVATION SCREW.
(4) To install the deactivation screw, do the steps that follow: NOTE: If the adaptor (T03) is installed, the deactivation screw has a preformed PACKING.
(a) Make sure that you install a new preformed PACKING on the deactivation screw if you removed the adaptor (T03). (b) Install the deactivation screw on the HP bleed valve.
(c) TORQUE the deactivation screw to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(d) Safety the deactivation screw on its support with the lockwire E. Removal of the Tool (HP Bleed Valve without the Deactivation Screw on the Regulator)
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL
(2) Disconnect the adaptor (T04) from the sense line.
(3) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
(b) Connect the sense line to the HP bleed valve.
(c) Do the double torque method on the union of the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
.
1 Double torque method:
a Torque a first time the union of the sense line to the given value.
b Loosen the union of the sense line a quarter of a turn.
c Torque a second time the union to the given value.
(d) Make a mark on the union of the sense line with paint.
5. Close-up
Functional Test of Sense Line between the HP Bleed Valve (without Deactivation Screw on Regulator) and the Bleed-Pressure Regulator Valve ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START TO REMOVE THE TOOLING, MAKE SURE THAT THERE IS NO PRESSURIZED GAS LEFT INSIDE THE DUCTS. IT CAN CAUSE AN INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU CONNECT/DISCONNECT THE TEST SET TO/FROM THE EQUIPMENT.
THE PRESSURE REGULATING VALVE AND THE PRESSURE GAGE ASSEMBLY OF THE TEST SET ARE HEAVY AND CAN CAUSE DAMAGE TO THE ENGINE.
(1) Make sure that the duct is not pressurized before removal of the tool. (2) Disconnect the adaptor (T04) from the sense line.
(3) Remove the SBE2213 KIT TOOL-TESTER SENSE LINE (Z02), 98L36103002000 TEST SET - ENGINE BLEED (Z01) and AIR SOURCE 6.9 BAR (100 PSI) - REGULATED,FILTERED, DRY (Z03) from the engine.
CAUTION:
TO PREVENT DAMAGE TO THE FITTING END OF THE SENSE LINE, TURN THE UNION WITH YOUR HAND AND NOT WITH A SPANNER.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT THE PNEUMATIC LINES ON UNIONS.
(4) Connection of the sense line: NOTE: There must be no grease or oil on the pneumatic and sense line unions.
(a) Remove the PLUG - BLANKING from the HP bleed valve. (b) Connect the sense line to the HP bleed valve.
(c) Do the double torque method on the union of the sense line to between 1.69 and 1.52 m.daN (12.46 and 11.21 lbf.ft )
. 1 Double torque method:
a Torque a first time the union of the sense line to the given value.
b Loosen the union of the sense line a quarter of a turn.
c Torque a second time the union to the given value.
(d) Make a mark on the union of the sense line with paint.
Subtask 36-11-00-410-101-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-071-A ** ON A/C NOT FOR ALL Subtask 36-11-00-410-102-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-101-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-071-B ** ON A/C NOT FOR ALL Subtask 36-11-00-410-102-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser half (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
F. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
Subtask 36-11-00-410-101-C ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the WARNING NOTICE(S).
(4) Remove the access platform(s).
G. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-071-C ** ON A/C NOT FOR ALL Subtask 36-11-00-410-102-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
I. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Subtask 36-11-00-862-086-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Close the access door 191MB.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).