Operational Test to read the CURRENT STATUS of the Engine Bleed Air System
TASK 36-11-00-710-001-A
Operational Test to read the CURRENT STATUS of the Engine Bleed Air System
1. Reason for the Job
To check the continuity and integrity of electrical wiring of Bleed Air System.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-074-A ** ON A/C NOT FOR ALL Subtask 36-11-00-860-065-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-710-050-D ** ON A/C NOT FOR ALL
Subtask 36-11-00-860-063-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:06:45 UTC
Operational Test to read the CURRENT STATUS of the Engine Bleed Air System
1. Reason for the Job
To check the continuity and integrity of electrical wiring of Bleed Air System.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-011-A | Procedure to Get Access to the SYSTEM REPORT/TEST/PNEU Page |
Subtask 36-11-00-861-074-A ** ON A/C NOT FOR ALL Subtask 36-11-00-860-065-A ** ON A/C NOT FOR ALL
B. Safety Precautions
(1) On the maintenance panel 50VU:
Subtask 36-11-00-865-054-A ** ON A/C NOT FOR ALL (1) On the maintenance panel 50VU:
- make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off,
- put a WARNING NOTICE(S) to tell persons not to operate the FADEC 1(2).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 36-11-00-860-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/X FEED/VALVE/BAT | 2HV | D13 |
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
| 122VU | AIR BLEED/X FEED VALVE/NORM | 1HV | Z20 |
D. Aircraft Maintenance Configuration
(1) On the AIR COND panel 30VU:
4. Procedure(1) On the AIR COND panel 30VU:
- make sure that all the ENG BLEED pushbutton switches are pushed (OFF legends are off),
- make sure that the X BLEED selector switch is at AUTO.
Subtask 36-11-00-710-050-D ** ON A/C NOT FOR ALL
A. Operational Test to Read the CURRENT DATA of the Engine Bleed-Air System
(1) LABEL : 055
(2) LABEL : 064 ! For BMC 1
(3) LABEL : 064 ! For BMC 2
(4) LABEL : 065 ! For BMC 1
(5) LABEL : 065 ! For BMC 2
(6) LABEL : 066 ! For BMC 1
(7) LABEL : 066 ! For BMC 2
(8) LABEL : 067 ! For BMC 1
(9) LABEL : 067 ! For BMC 2
Subtask 36-11-00-710-050-I ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the MCDU:
| On the MCDU:
|
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | FAULT COMMAND | FAULT | NO FAULT | |
| 12 | APU BLEED PUSH BUTTON POSITION | ON | OFF | |
| 13 | APU BLEED VALVE POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENABLE APU BLEED VALVE OPENING (OUTPUT SIGNAL) | ENABLE | NOT ENABLE | |
| 15 | CROSS FEED VALVE POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 16 | CROSS FEED VALVE POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 17 | CROSS FEED VALVE SELECTOR POSITION | SHUT | NOT SHUT | |
| 18 | CROSS FEED VALVE SELECTOR POSITION | OPEN | NOT OPEN | |
| 19 | CROSS FEED VALVE AUTO OPENING CONTROL (OUTPUT) | OPENING CONTROL | NOT OPENING CONTROL | |
| 20 | CROSS FEED VALVE MAN OPENING DISAGREE | NO DISAGREE | DISAGREE | Opening control and not fully open |
| 21 | CROSS FEED VALVE MAN CLOSURE DISAGREE | NO DISAGREE | DISAGREE | Closure control and not fully closed |
| 22 | CROSS FEED VALVE AUTO OPENING DISAGREE | NO DISAGREE | DISAGREE | Opening control and not fully open |
| 23 | CROSS FEED VALVE AUTO CLOSURE DISAGREE | NO DISAGREE | DISAGREE | Closure control and not fully closed |
| 24 | CLOSE PRV COMMAND | NOT CLOSE | CLOSE | |
| 25 | APU LEAK MEMORIZED (OUTPUT SIGNAL) | NO LEAK | LEAK | Signal self maintened as long as APU P/B sw in not resetted |
| 26 | OPEN X FEED COMMAND | OPEN | NOT OPEN | |
| 27 | OPEN APU COMMAND | OPEN | NOT OPEN | |
| 28 | APU LEAK MEMORIZED | NO LEAK | LEAK | |
| 29 | WAI COMMAND | IN RANGE | OUT RANGE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | | | | |
| 12 | RIGHT WING LEAK | NO LEAK | LEAK | |
| 13 | ENG2 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 14 | | | | |
| 15 | RIGHT WING LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintened as long as BLEED 2 P/B sw in not resetted |
| 16 | RIGHT LEAK LOOP A | NO LEAK | LEAK | |
| 17 | OVERPRESS-ENG2 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG2 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG2 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | Signal self maintened as long |
| 20 | OVERHEAT-ENG2 MEMORIZED | NO OVERHEAT | OVERHEAT | in not resetted |
| 21 | | | | |
| 22 | | | | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | | | | |
| 28 | RIGHT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | RIGHT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | PYLON ENG2 LEAK | NO LEAK | LEAK | |
| 12 | RIGHT WING LEAK | NO LEAK | LEAK | |
| 13 | RIGHT LEAK LOOP B | NO LEAK | LEAK | |
| 14 | PYLON ENG2 LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintened as long |
| 15 | RIGHT WING LEAK MEMORIZED | NO LEAK | LEAK | in not resetted |
| 16 | ENG2 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 17 | OVERPRESS-ENG2 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG2 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG2 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | |
| 20 | OVERHEAT-ENG2 MEMORIZED | NO OVERHEAT | OVERHEAT | maintened as long as BLEED 2 P/B sw |
| 21 | ENG2 PRV AUTO CLOSURE CTL DISAGREE | NO DISAGREE | DISAGREE | |
| 22 | ENG2 HPV FAULT | NO FAULT | FAULT | |
| 23 | | | | |
| 24 | | | | |
| 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | |
| 26 | ENG2 ABNORMAL PR | NO | YES | |
| 27 | PYLON 2 LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 28 | RIGHT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | RIGHT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | PYLON ENG1 LEAK | NO LEAK | LEAK | |
| 12 | LEFT WING LEAK | NO LEAK | LEAK | |
| 13 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 14 | PYLON ENG1 LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintened as long |
| 15 | LEFT WING LEAK MEMORIZED | NO LEAK | LEAK | in not resetted |
| 16 | LEFT LEAK LOOP A | NO LEAK | LEAK | |
| 17 | OVERPRESS-ENG1 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG1 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | |
| 20 | OVERHEAT-ENG1 MEMORIZED | NO OVERHEAT | OVERHEAT | maintened as long as BLEED 1 P/B sw |
| 21 | ENG1 PRV AUTO CLOSURE CTL DISAGREE | NO DISAGREE | DISAGREE | |
| 22 | ENG1 HPV FAULT | NO FAULT | FAULT | |
| 23 | APU LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 24 | APU LEAK | NO LEAK | LEAK | |
| 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | |
| 26 | ENG1 ABNORMAL PR | NO | YES | |
| 27 | PYLON 1 LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 28 | LEFT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | LEFT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | | | | |
| 12 | LEFT WING LEAK | NO LEAK | LEAK | |
| 13 | LEFT LEAK LOOP B | NO LEAK | LEAK | |
| 14 | | | | |
| 15 | LEFT WING LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintened as long as BLEED 1 P/B sw in not resetted |
| 16 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 17 | OVERPRESS-ENG1 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG1 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | Signal self maintened as long |
| 20 | OVERHEAT-ENG1 MEMORIZED | NO OVERHEAT | OVERHEAT | in not resetted |
| 21 | | | | |
| 22 | | | | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | | | | |
| 28 | LEFT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | LEFT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | WAI P/B SELECTED | ON | OFF | |
| 12 | | | | |
| 13 | | | | |
| 14 | | | | |
| 15 | ENG2 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | | | | |
| 17 | ENG2 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG2 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | | | | |
| 20 | | | | |
| 21 | STARTER VALVE ENG2 | CLOSED | NOT CLOSED | |
| 22 | VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | HPV SOLENOID COMMAND | NO COMMAND | COMMAND | |
| 28 | HPV SOLENOID CONTROL | NO CONTROL | CONTROL | Output state |
| 29 | A/C 319 | NO | YES | Input AB 7A |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | ENG2 OPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 12 | ENG2 FAV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 13 | ENG2 FAV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENG2 HPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 15 | ENG2 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | ENG2 PRV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 17 | ENG2 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG2 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | ENG2 FIRE PUSH BUTTON POSITION | NORMAL | PUSHED | |
| 20 | PRV2 LOW REGULATION | NO | YES | |
| 21 | STARTER VALVE ENG2 | CLOSED | NOT CLOSED | |
| 22 | VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | CFM VALIDITY | NO | YES | |
| 24 | IAE VALIDITY | NO | YES | |
| 25 | ENG2 HPV SOLENOID | NO ENERGIZED | ENERGIZED | |
| 26 | ENG2 PRV CLOSURE CONTROL | NO CONTROL | CONTROL | Output state |
| 27 | ENG2 PRECOOLER INLET PRESSURE STATUS | 12psig<P< 60psig | 60psig<P< 12psig | Output state |
| 28 | ENG2 BLEED FAULT | FAULT | NO FAULT | Signal self maintened as long as BLEED 2 P/B sw in not resetted |
| 29 | ENG2 PRV PWR SUPPLY | NO POWER | POWER | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | ENG1 OPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 12 | ENG1 FAV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 13 | ENG1 FAV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENG1 HPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 15 | ENG1 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | ENG1 PRV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 17 | ENG1 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG1 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | ENG1 FIRE PUSH BUTTON POSITION | NORMAL | PUSHED | |
| 20 | PRV1 LOW REGULATION | NO | YES | |
| 21 | STARTER VALVE ENG1 | CLOSED | NOT CLOSED | |
| 22 | VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | CFM VALIDITY | NO | YES | |
| 24 | IAE VALIDITY | NO | YES | |
| 25 | ENG1 HPV SOLENOID | NO ENERGIZED | ENERGIZED | |
| 26 | ENG1 PRV CLOSURE CONTROL | NO CONTROL | CONTROL | Output state |
| 27 | ENG1 PRECOOLER INLET PRESSURE STATUS | 12psig<PR< 60psig | 60psig<PR< 12psig | Output state |
| 28 | ENG1 BLEED FAULT | FAULT | NO FAULT | Signal self maintened as long as BLEED 1 P/B sw in not resetted |
| 29 | ENG1 PRV PWR SUPPLY | NO POWER | POWER | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | WAI P/B SELECTED | ON | OFF | |
| 12 | | | | |
| 13 | | | | |
| 14 | | | | |
| 15 | ENG1 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | | | | |
| 17 | ENG1 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG1 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | | | | |
| 20 | | | | |
| 21 | STARTER VALVE ENG1 | CLOSED | NOT CLOSED | |
| 22 | VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | HPV SOLENOID COMMAND | NO COMMAND | COMMAND | |
| 28 | HPV SOLENOID CONTROL | NO CONTROL | CONTROL | Output state |
| 29 | A/C 319 | NO | YES | Input AB 7A |
A. Operational Test to Read the CURRENT DATA of the Engine Bleed-Air System
(1) LABEL : 055
(2) LABEL : 064 ! For BMC 1
(3) LABEL : 064 ! For BMC 2
(4) LABEL : 065 ! For BMC 1
(5) LABEL : 065 ! For BMC 2
(6) LABEL : 066 ! For BMC 1
(7) LABEL : 066 ! For BMC 2
(8) LABEL : 067 ! For BMC 1
(9) LABEL : 067 ! For BMC 2
Subtask 36-11-00-710-050-J ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the MCDU:
| On the MCDU:
|
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | FAULT COMMAND | FAULT | NO FAULT | |
| 12 | APU BLEED PUSH BUTTON POSITION | ON | OFF | |
| 13 | APU BLEED VALVE POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENABLE APU BLEED VALVE OPENING CONTROL | ENABLE | NOT ENABLE | Output signal |
| 15 | CROSS FEED VALVE POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 16 | CROSS FEED VALVE POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 17 | CROSS FEED VALVE SELECTOR POSITION | SHUT | NOT SHUT | |
| 18 | CROSS FEED VALVE SELECTOR POSITION | OPEN | NOT OPEN | |
| 19 | CROSS FEED VALVE AUTO OPENING CONTROL | OPENING CONTROL | NOT OPENING CONTROL | Output signal |
| 20 | CROSS FEED VALVE MAN OPENING DISAGREE | NO DISAGREE | DISAGREE | Opening control and not fully open |
| 21 | CROSS FEED VALVE MAN CLOSURE DISAGREE | NO DISAGREE | DISAGREE | Closure control and not fully closed |
| 22 | CROSS FEED VALVE AUTO OPENING DISAGREE | NO DISAGREE | DISAGREE | Opening control and not fully open |
| 23 | CROSS FEED VALVE AUTO CLOSURE DISAGREE | NO DISAGREE | DISAGREE | Closure control and not fully closed |
| 24 | CLOSE PRV COMMAND | NOT CLOSE | CLOSE | |
| 25 | APU LEAK DETECTION | NO LEAK | LEAK | Output signal |
| 26 | OPEN X FEED COMMAND | OPEN | NOT OPEN | |
| 27 | OPEN APU COMMAND | OPEN | NOT OPEN | |
| 28 | APU LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as long as APU P/BSW is pushed |
| 29 | WAI COMMAND | IN RANGE | OUT RANGE | is pushed |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | | | | |
| 12 | RIGHT WING LEAK | NO LEAK | LEAK | |
| 13 | ENG2 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 14 | | | | |
| 15 | RIGHT WING LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as long as BLEED 2 P/BSW is pushed |
| 16 | RIGHT WING LEAK LOOP A | NO LEAK | LEAK | |
| 17 | OVERPRESS-ENG2 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG2 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG2 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | Signal self maintained as |
| 20 | OVERHEAT-ENG2 MEMORIZED | NO OVERHEAT | OVERHEAT | P/BSW is pushed |
| 21 | | | | |
| 22 | | | | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | | | | |
| 28 | RIGHT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | RIGHT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | PYLON ENG2 LEAK | NO LEAK | LEAK | |
| 12 | RIGHT WING LEAK | NO LEAK | LEAK | |
| 13 | RIGHT WING LEAK LOOP B | NO LEAK | LEAK | |
| 14 | PYLON ENG2 LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as |
| 15 | RIGHT WING LEAK MEMORIZED | NO LEAK | LEAK | P/BSW is pushed |
| 16 | ENG2 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 17 | OVERPRESS-ENG2 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG2 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG2 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | |
| 20 | OVERHEAT-ENG2 MEMORIZED | NO OVERHEAT | OVERHEAT | maintained as long as BLEED 2 |
| 21 | ENG2 PRV AUTO CLOSURE CTL DISAGREE | NO DISAGREE | DISAGREE | |
| 22 | ENG2 HPV FAULT | NO FAULT | FAULT | |
| 23 | | | | |
| 24 | | | | |
| 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | |
| 26 | ENG2 ABNORMAL PR | NO | YES | |
| 27 | PYLON 2 LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 28 | RIGHT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | RIGHT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | PYLON ENG1 LEAK | NO LEAK | LEAK | |
| 12 | LEFT WING LEAK | NO LEAK | LEAK | |
| 13 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 14 | PYLON ENG1 LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as |
| 15 | LEFT WING LEAK MEMORIZED | NO LEAK | LEAK | P/BSW is pushed |
| 16 | LEFT WING LEAK LOOP A | NO LEAK | LEAK | |
| 17 | OVERPRESS-ENG1 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG1 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | |
| 20 | OVERHEAT-ENG1 MEMORIZED | NO OVERHEAT | OVERHEAT | maintained as long as BLEED 1 |
| 21 | ENG1 PRV AUTO CLOSURE CTL DISAGREE | NO DISAGREE | DISAGREE | |
| 22 | ENG1 HPV FAULT | NO FAULT | FAULT | |
| 23 | APU LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 24 | APU LEAK | NO LEAK | LEAK | |
| 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | |
| 26 | ENG1 ABNORMAL PR | NO | YES | |
| 27 | PYLON 1 LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 28 | LEFT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | LEFT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | | | | |
| 12 | LEFT WING LEAK | NO LEAK | LEAK | |
| 13 | LEFT LEAK LOOP B | NO LEAK | LEAK | |
| 14 | | | | |
| 15 | LEFT WING LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as long as BLEED 1 P/BSW is pushed |
| 16 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 17 | OVERPRESS-ENG1 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG1 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | Signal self maintained as |
| 20 | OVERHEAT-ENG1 MEMORIZED | NO OVERHEAT | OVERHEAT | P/BSW is pushed |
| 21 | | | | |
| 22 | | | | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | | | | |
| 28 | LEFT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | LEFT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | WAI P/B SELECTED | ON | OFF | |
| 12 | | | | |
| 13 | | | | |
| 14 | | | | |
| 15 | ENG2 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | | | | |
| 17 | ENG2 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG2 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | | | | |
| 20 | | | | |
| 21 | STARTER VALVE ENG2 | CLOSED | NOT CLOSED | |
| 22 | PACK 2 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | | | | |
| 24 | | | | |
| 25 | A/C A318 | NO | YES | Input AB 8A |
| 26 | | | | |
| 27 | HPV1 SOLENOID COMMAND | NO COMMAND | COMMAND | |
| 28 | HPV1 SOLENOID CONTROL | NO CONTROL | CONTROL | Output state |
| 29 | A/C A319 | NO | YES | Input AB 7A |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | ENG2 OPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 12 | ENG2 FAV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 13 | ENG2 FAV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENG2 HPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 15 | ENG2 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | ENG2 PRV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 17 | ENG2 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG2 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | ENG2 FIRE PUSH BUTTON POSITION | NORMAL | PUSHED | |
| 20 | PRV2 LOW REGULATION | NO | YES | |
| 21 | STARTER VALVE ENG2 | CLOSED | NOT CLOSED | |
| 22 | PACK 2 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | CFM VALIDITY | NO | YES | * |
| 24 | IAE VALIDITY | NO | YES | * |
| 25 | ENG2 HPV SOLENOID ENERGIZED | NO ENERGIZED | ENERGIZED | All engine |
| 26 | ENG2 PRV CLOSURE CONTROL | NO CONTROL | CONTROL | Output state |
| 27 | ENG2 PRECOOLER INLET PRESSURE STATUS | 12psig<P< 60psig | 60psig<P< 12psig | Output state |
| 28 | ENG2 BLEED FAULT | FAULT | NO FAULT | Signal self maintained as long as BLEED 2 P/BSW is pushed |
| 29 | ENG2 PRV PWR SUPPLY | NO POWER | POWER | |
(8) LABEL : 067 ! For BMC 1
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | ENG1 OPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 12 | ENG1 FAV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 13 | ENG1 FAV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENG1 HPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 15 | ENG1 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | ENG1 PRV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 17 | ENG1 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG1 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | ENG1 FIRE PUSH BUTTON POSITION | NORMAL | PUSHED | |
| 20 | PRV1 LOW REGULATION | NO | YES | |
| 21 | STARTER VALVE ENG1 | CLOSED | NOT CLOSED | |
| 22 | PACK 1 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | CFM VALIDITY | NO | YES | * |
| 24 | IAE VALIDITY | NO | YES | * |
| 25 | ENG1 HPV SOLENOID ENERGIZED | NO ENERGIZED | ENERGIZED | All engine |
| 26 | ENG1 PRV CLOSURE CONTROL | NO CONTROL | CONTROL | Output state |
| 27 | ENG1 PRECOOLER INLET PRESSURE STATUS | 12psig<PR< 60psig | 60psig<PR< 12psig | Output state |
| 28 | ENG1 BLEED FAULT | FAULT | NO FAULT | Signal self maintained as long as BLEED 1 P/BSW is pushed |
| 29 | ENG1 PRV PWR SUPPLY | NO POWER | POWER | |
(9) LABEL : 067 ! For BMC 2
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | WAI P/B SELECTED | ON | OFF | |
| 12 | | | | |
| 13 | | | | |
| 14 | | | | |
| 15 | ENG1 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | | | | |
| 17 | ENG1 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG1 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | | | | |
| 20 | | | | |
| 21 | STARTER VALVE ENG1 | CLOSED | NOT CLOSED | |
| 22 | PACK 1 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | | | | |
| 24 | | | | |
| 25 | A/C A318 | NO | YES | Input AB 8A |
| 26 | | | | |
| 27 | HPV2 SOLENOID COMMAND | NO COMMAND | COMMAND | |
| 28 | HPV2 SOLENOID CONTROL | NO CONTROL | CONTROL | Output state |
| 29 | A/C A319 | NO | YES | Input AB 7A |
A. Operational Test to Read the CURRENT DATA of the Engine Bleed-Air System
(1) LABEL : 055
(2) LABEL : 064 ! For BMC 1
(3) LABEL : 064 ! For BMC 2
(4) LABEL : 065 ! For BMC 1
(5) LABEL : 065 ! For BMC 2
(6) LABEL : 066 ! For BMC 1
(7) LABEL : 066 ! For BMC 2
(8) LABEL : 067 ! For BMC 1
(9) LABEL : 067 ! For BMC 2
5. Close-up| ACTION | RESULT |
|---|---|
1.On the MCDU:
| On the MCDU:
|
2.On the MCDU:
| On the MCDU:
|
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | FAULT COMMAND | FAULT | NO FAULT | |
| 12 | APU BLEED PUSH BUTTON POSITION | ON | OFF | |
| 13 | APU BLEED VALVE POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENABLE APU BLEED VALVE OPENING CONTROL | ENABLE | NOT ENABLE | Output signal |
| 15 | CROSS FEED VALVE POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 16 | CROSS FEED VALVE POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 17 | CROSS FEED VALVE SELECTOR POSITION | SHUT | NOT SHUT | |
| 18 | CROSS FEED VALVE SELECTOR POSITION | OPEN | NOT OPEN | |
| 19 | CROSS FEED VALVE AUTO OPENING CONTROL | OPENING CONTROL | NOT OPENING CONTROL | Output signal |
| 20 | CROSS FEED VALVE MAN OPENING DISAGREE | NO DISAGREE | DISAGREE | Opening control and not fully open |
| 21 | CROSS FEED VALVE MAN CLOSURE DISAGREE | NO DISAGREE | DISAGREE | Closure control and not fully closed |
| 22 | CROSS FEED VALVE AUTO OPENING DISAGREE | NO DISAGREE | DISAGREE | Opening control and not fully open |
| 23 | CROSS FEED VALVE AUTO CLOSURE DISAGREE | NO DISAGREE | DISAGREE | Closure control and not fully closed |
| 24 | CLOSE PRV COMMAND | NOT CLOSE | CLOSE | |
| 25 | APU LEAK DETECTION | NO LEAK | LEAK | Output signal |
| 26 | OPEN X FEED COMMAND | OPEN | NOT OPEN | |
| 27 | OPEN APU COMMAND | OPEN | NOT OPEN | |
| 28 | APU LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as long as APU P/BSW is pushed |
| 29 | WAI COMMAND | IN RANGE | OUT RANGE | is pushed |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | | | | |
| 12 | RIGHT WING LEAK | NO LEAK | LEAK | |
| 13 | ENG2 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 14 | | | | |
| 15 | RIGHT WING LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as long as BLEED 2 P/BSW is pushed |
| 16 | RIGHT WING LEAK LOOP A | NO LEAK | LEAK | |
| 17 | OVERPRESS-ENG2 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG2 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG2 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | Signal self maintained as |
| 20 | OVERHEAT-ENG2 MEMORIZED | NO OVERHEAT | OVERHEAT | P/BSW is pushed |
| 21 | | | | |
| 22 | | | | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | | | | |
| 28 | RIGHT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | RIGHT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | PYLON ENG2 LEAK | NO LEAK | LEAK | |
| 12 | RIGHT WING LEAK | NO LEAK | LEAK | |
| 13 | RIGHT WING LEAK LOOP B | NO LEAK | LEAK | |
| 14 | PYLON ENG2 LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as |
| 15 | RIGHT WING LEAK MEMORIZED | NO LEAK | LEAK | P/BSW is pushed |
| 16 | ENG2 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 17 | OVERPRESS-ENG2 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG2 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG2 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | |
| 20 | OVERHEAT-ENG2 MEMORIZED | NO OVERHEAT | OVERHEAT | maintained as long as BLEED 2 |
| 21 | ENG2 PRV AUTO CLOSURE CTL DISAGREE | NO DISAGREE | DISAGREE | |
| 22 | ENG2 HPV FAULT | NO FAULT | FAULT | |
| 23 | | | | |
| 24 | | | | |
| 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | |
| 26 | ENG2 ABNORMAL PR | NO | YES | |
| 27 | PYLON 2 LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 28 | RIGHT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | RIGHT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | PYLON ENG1 LEAK | NO LEAK | LEAK | |
| 12 | LEFT WING LEAK | NO LEAK | LEAK | |
| 13 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 14 | PYLON ENG1 LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as |
| 15 | LEFT WING LEAK MEMORIZED | NO LEAK | LEAK | P/BSW is pushed |
| 16 | LEFT WING LEAK LOOP A | NO LEAK | LEAK | |
| 17 | OVERPRESS-ENG1 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG1 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | |
| 20 | OVERHEAT-ENG1 MEMORIZED | NO OVERHEAT | OVERHEAT | maintained as long as BLEED 1 |
| 21 | ENG1 PRV AUTO CLOSURE CTL DISAGREE | NO DISAGREE | DISAGREE | |
| 22 | ENG1 HPV FAULT | NO FAULT | FAULT | |
| 23 | APU LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 24 | APU LEAK | NO LEAK | LEAK | |
| 25 | AIR CLASS II FAILURE | ABSENT | PRESENT | |
| 26 | ENG1 ABNORMAL PR | NO | YES | |
| 27 | PYLON 1 LOOP STATUS | OPERATIVE | NOT OPERATIVE | |
| 28 | LEFT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | LEFT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | | | | |
| 12 | LEFT WING LEAK | NO LEAK | LEAK | |
| 13 | LEFT LEAK LOOP B | NO LEAK | LEAK | |
| 14 | | | | |
| 15 | LEFT WING LEAK MEMORIZED | NO LEAK | LEAK | Signal self maintained as long as BLEED 1 P/BSW is pushed |
| 16 | ENG1 LOW TEMPERATURE | NORMAL | LOW TEMP | |
| 17 | OVERPRESS-ENG1 | NO OVERPRESSURE | OVERPRESSURE | |
| 18 | OVERHEAT-ENG1 | NO OVERHEAT | OVERHEAT | |
| 19 | OVERPRESS-ENG1 MEMORIZED | NO OVERPRESSURE | OVERPRESSURE | Signal self maintained as |
| 20 | OVERHEAT-ENG1 MEMORIZED | NO OVERHEAT | OVERHEAT | P/BSW is pushed |
| 21 | | | | |
| 22 | | | | |
| 23 | | | | |
| 24 | | | | |
| 25 | | | | |
| 26 | | | | |
| 27 | | | | |
| 28 | LEFT WING LOOP A STATUS | OPERATIVE | NOT OPERATIVE | |
| 29 | LEFT WING LOOP B STATUS | OPERATIVE | NOT OPERATIVE | |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | WAI P/B SELECTED | ON | OFF | |
| 12 | | | | |
| 13 | HPV SOLENOID CONTROL BY FADEC | NO CONTROL | CONTROL | |
| 14 | | | | |
| 15 | ENG2 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | | | | |
| 17 | ENG2 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG2 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | | | | |
| 20 | | | | |
| 21 | STARTER VALVE ENG2 | CLOSED | NOT CLOSED | |
| 22 | PACK 2 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | | | | |
| 24 | | | | |
| 25 | A/C A318 | NO | YES | Input AB 8A |
| 26 | | | | |
| 27 | HPV1 SOLENOID COMMAND | NO COMMAND | COMMAND | |
| 28 | HPV1 SOLENOID CONTROL | NO CONTROL | CONTROL | Output state |
| 29 | A/C A319 | NO | YES | Input AB 7A |
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | ENG2 OPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 12 | ENG2 FAV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 13 | ENG2 FAV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENG2 HPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 15 | ENG2 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | ENG2 PRV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 17 | ENG2 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG2 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | ENG2 FIRE PUSH BUTTON POSITION | NORMAL | PUSHED | |
| 20 | PRV2 LOW REGULATION | NO | YES | |
| 21 | STARTER VALVE ENG2 | CLOSED | NOT CLOSED | |
| 22 | PACK 2 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | CFM VALIDITY | NO | YES | * |
| 24 | IAE VALIDITY | NO | YES | * |
| 25 | ENG2 HPV SOLENOID ENERGIZED | NO ENERGIZED | ENERGIZED | All engine |
| 26 | ENG2 PRV CLOSURE CONTROL | NO CONTROL | CONTROL | Output state |
| 27 | ENG2 PRECOOLER INLET PRESSURE STATUS | 12psig<P< 60psig | 60psig<P< 12psig | Output state |
| 28 | ENG2 BLEED FAULT | FAULT | NO FAULT | Signal self maintained as long as BLEED 2 P/BSW is pushed |
| 29 | ENG2 PRV PWR SUPPLY | NO POWER | POWER | |
(8) LABEL : 067 ! For BMC 1
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | ENG1 OPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 12 | ENG1 FAV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 13 | ENG1 FAV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 14 | ENG1 HPV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 15 | ENG1 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | ENG1 PRV POSITION | FULLY OPEN | NOT FULLY OPEN | |
| 17 | ENG1 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG1 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | ENG1 FIRE PUSH BUTTON POSITION | NORMAL | PUSHED | |
| 20 | PRV1 LOW REGULATION | NO | YES | |
| 21 | STARTER VALVE ENG1 | CLOSED | NOT CLOSED | |
| 22 | PACK 1 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | CFM VALIDITY | NO | YES | * |
| 24 | IAE VALIDITY | NO | YES | * |
| 25 | ENG1 HPV SOLENOID ENERGIZED | NO ENERGIZED | ENERGIZED | All engine |
| 26 | ENG1 PRV CLOSURE CONTROL | NO CONTROL | CONTROL | Output state |
| 27 | ENG1 PRECOOLER INLET PRESSURE STATUS | 12psig<PR< 60psig | 60psig<PR< 12psig | Output state |
| 28 | ENG1 BLEED FAULT | FAULT | NO FAULT | Signal self maintained as long as BLEED 1 P/BSW is pushed |
| 29 | ENG1 PRV PWR SUPPLY | NO POWER | POWER | |
(9) LABEL : 067 ! For BMC 2
| BIT | PARAMETER DEFINITION | STATUS 0 | STATUS 1 | COMMENTS |
|---|---|---|---|---|
| 11 | WAI P/B SELECTED | ON | OFF | |
| 12 | | | | |
| 13 | HPV SOLENOID CONTROL BY FADEC | NO CONTROL | CONTROL | |
| 14 | | | | |
| 15 | ENG1 HPV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 16 | | | | |
| 17 | ENG1 PRV POSITION | FULLY CLOSED | NOT FULLY CLOSED | |
| 18 | ENG1 BLEED PUSH BUTTON POSITION | OFF | ON | |
| 19 | | | | |
| 20 | | | | |
| 21 | STARTER VALVE ENG1 | CLOSED | NOT CLOSED | |
| 22 | PACK 1 VALVE CLOSURE FOR ENG START | NO | YES | |
| 23 | | | | |
| 24 | | | | |
| 25 | A/C A318 | NO | YES | Input AB 8A |
| 26 | | | | |
| 27 | HPV2 SOLENOID COMMAND | NO COMMAND | COMMAND | |
| 28 | HPV2 SOLENOID CONTROL | NO CONTROL | CONTROL | Output state |
| 29 | A/C A319 | NO | YES | Input AB 7A |
Subtask 36-11-00-860-063-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the MCDU, push the MCDU MENU mode key to get the MCDU MENU page.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) On the MCDU, push the MCDU MENU mode key to get the MCDU MENU page.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
BMC 1 (BMC 2) CURRENT DATA