W DOC AIRBUS | AMM A320F

Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with Engine 2 Bleed Pressure and the TCT P/N SBE2272


TASK 36-11-00-615-805-A-03
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with Engine 2 Bleed Pressure and the TCT P/N SBE2272


WARNING: MAKE SURE THAT WHEN THE ENGINES OPERATE ON THE GROUND:
  • NO PERSONS GO WHERE THE AIRCRAFT CAN CAUSE THEM INJURY OR CAN KILL THEM
  • NO OBJECTS STAY WHERE THE ENGINES CAN BLOW THEM AWAY OR WHERE THEY CAN BE PULLED INTO THE ENGINES BY SUCTION.
WARNING: MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN THE DUCTS ARE DISCONNECTED THE TEMPERATURE OF THE EXHAUST GASES FROM THE OPEN ENDS OF THE DISCONNECTED DUCTS CAN BE AS HIGH AS 270 DEG.C (518 DEG.F). THE HOT GASES CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: ALWAYS USE APPLICABLE GLOVES TO TOUCH HOT PARTS. HOT PARTS CAN CAUSE INJURY TO PERSONS.
ZONE: 410
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
BLANKET - HEAT ISOLATION
No specific
AR
COVER - PROTECTION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
SBE2272
1
TCT 230 DEG CELCIUS - BLEED
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
410
ENG 1 PYLON BOX AND FORWARD FAIRING
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-51-00-710-002-A
Operational Test of the Flow Control and Indicating System
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
TASK 36-11-00-720-005-A
Leak Check of Engine Bleed Air Supply System and Packs Components with APU Bleed Air
TASK 36-11-43-000-001-A
Removal of the Fan-Air Valve Control-Thermostat
TASK 36-11-43-400-001-A
Installation of the Fan-Air Valve Control-Thermostat
TASK 36-11-49-000-001-A
Removal of the Mid Stage Tee Duct
TASK 36-11-49-000-010-B
Removal of the Upper Bleed-Air Duct
TASK 36-11-49-000-040-A
Removal of the Pylon Interface Duct
TASK 36-11-49-000-042-A
Removal of the Pylon Interface Duct
TASK 36-11-49-000-043-A
Removal of the Mid Stage Tee Duct
TASK 36-11-49-400-001-A
Installation of the Mid Stage Tee Duct
TASK 36-11-49-400-010-B
Installation of the Upper Bleed-Air Duct
TASK 36-11-49-400-040-A
Installation of the Pylon Interface Duct
TASK 36-11-49-400-042-A
Installation of the Pylon Interface Duct
TASK 36-11-49-400-043-A
Installation of the Mid Stage Tee Duct
TASK 71-00-00-710-003-A
Engine Automatic Start
TASK 71-00-00-710-003-B
Engine Automatic Start
TASK 71-00-00-710-018-A
Discontinued Start, Restart and Shutdown Procedures
TASK 71-00-00-710-028-A
Engine Shutdown
TASK 71-00-00-710-028-B
Engine Shutdown
TASK 71-00-00-710-043-A
Normal Engine Automatic-Start Procedure
TASK 71-00-00-860-012-A
Engine Safety Precautions
TASK 71-00-00-869-004-A
Safety Precautions During Engine Ground Operations
TASK 71-00-00-869-006-A
Safety Precautions During Engine Ground Operations
F Pressure Regulating Valve ** ON A/C NOT FOR ALL
F Pressure Regulating Valve ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 36-11-00-941-201-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Obey the safety precautions during engine ground operations (Ref. AMM TASK 71-00-00-869-006).
Subtask 36-11-00-941-201-B ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Obey the safety precautions during engine ground operations (Ref. AMM TASK 71-00-00-860-012).
Subtask 36-11-00-941-201-D ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Obey the safety precautions during engine ground operations (Ref. AMM TASK 71-00-00-869-004).
Subtask 36-11-00-865-261-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
Subtask 36-11-00-865-256-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
Subtask 36-11-00-860-259-A ** ON A/C NOT FOR ALL
D. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits from the external power (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
   (3) In the cockpit, on AIR COND panel 30VU:
     (a) Make sure that the ENG 1 and 2 BLEED pushbutton-switch is released (the OFF legends are on).
     (b) Make sure that the APU BLEED pushbutton-switch is released (the ON legend is off).
     (c) Make sure that the PACK 1 and 2 pushbutton switches are released (the OFF legends are on).
     (d) Make sure that the PACK FLOW selector-switch is set to LO.
     (e) Make sure that the X BLEED selector-switch is in the AUTO position.
   (4) On the HP ground connector (7300HM):
     (a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
Subtask 36-11-00-480-162-A ** ON A/C NOT FOR ALL
E. Preparation for Cleaning of the Bleed-Air Ducting System
   (1) Install a SBE2272 TCT 230 DEG CELCIUS - BLEED:
     (a) Remove the Fan Air Valve (FAV) control thermostat (Ref. AMM TASK 36-11-43-000-001).
     (b) Install the SBE2272 TCT 230 DEG CELCIUS - BLEED (Ref. AMM TASK 36-11-43-400-001).
   (2) Start engine 2 and keep the engine RPM to idle (Ref. AMM TASK 71-00-00-710-003):
     (a) In the cockpit, on AIR COND panel 30VU:
       1 Make sure that the ENG 2 BLEED pushbutton switch is released (the OFF legend is on).
       2 Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
       3 Make sure that the X BLEED selector switch is in the SHUT position.
   (3) Remove the engine bleed-air duct as follows:
     (a) On the ECAM control panel, push the BLEED key:
       1 On the SD, the BLEED page comes into view.
       2 On the BLEED page, do a check of:
  • The pressure value in the duct that reads the bleed pressure sensor
  • The temperature value in the duct that reads the bleed temperature sensor.
     (b) When the pressure and temperature values in the duct are almost the same as the external pressure and temperature:
       1 Remove the bleed air duct from the PRV (4000HA1) of engine 1 (Ref. AMM TASK 36-11-49-000-001) and (Ref. AMM TASK 36-11-49-000-040).
   (4) Point the bleed-air joint duct away from the engine and the electrical cables or equipment.
NOTE: The open end of the bleed-air joint duct points in the direction where the hot bleed air is released freely to the atmosphere.
   (5) Put a COVER - PROTECTION on the open end of the PRV (4000HA1).
   (6) Put the BLANKET - HEAT ISOLATION on the adjacent electrical cables and components.
Subtask 36-11-00-480-162-B ** ON A/C NOT FOR ALL
E. Preparation for Cleaning of the Bleed-Air Ducting System
   (1) Install a SBE2272 TCT 230 DEG CELCIUS - BLEED:
     (a) Remove the Fan Air Valve (FAV) control thermostat (Ref. AMM TASK 36-11-43-000-001).
     (b) Install the SBE2272 TCT 230 DEG CELCIUS - BLEED (Ref. AMM TASK 36-11-43-400-001).
   (2) Start engine 2 and keep the engine RPM to idle (Ref. AMM TASK 71-00-00-710-043):
     (a) In the cockpit, on AIR COND panel 30VU:
       1 Make sure that the ENG 2 BLEED pushbutton switch is released (the OFF legend is on).
       2 Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
       3 Make sure that the X BLEED selector switch is in the SHUT position.
   (3) Remove the engine bleed-air duct as follows:
     (a) On the ECAM control panel, push the BLEED key:
       1 On the SD, the BLEED page comes into view.
       2 On the BLEED page, do a check of:
  • The pressure value in the duct that reads the bleed pressure sensor
  • The temperature value in the duct that reads the bleed temperature sensor.
     (b) When the pressure and temperature values in the duct are almost the same as the external pressure and temperature:
       1 Remove the bleed air duct from the PRV (4000HA1) of engine 1 (Ref. AMM TASK 36-11-49-000-010).
   (4) Point the bleed-air joint duct away from the engine and the electrical cables or equipment.
NOTE: The open end of the bleed-air joint duct points in the direction where the hot bleed air is released freely to the atmosphere.
   (5) Put a COVER - PROTECTION on the open end of the PRV (4000HA1).
   (6) Put the BLANKET - HEAT ISOLATION on the adjacent electrical cables and components.
Subtask 36-11-00-480-162-D ** ON A/C NOT FOR ALL
E. Preparation for Cleaning of the Bleed-Air Ducting System
   (1) Install a SBE2272 TCT 230 DEG CELCIUS - BLEED:
     (a) Remove the Fan Air Valve (FAV) control thermostat (Ref. AMM TASK 36-11-43-000-001).
     (b) Install the SBE2272 TCT 230 DEG CELCIUS - BLEED (Ref. AMM TASK 36-11-43-400-001).
   (2) Start engine 2 and keep the engine RPM to idle (Ref. AMM TASK 71-00-00-710-003):
     (a) In the cockpit, on AIR COND panel 30VU:
       1 Make sure that the ENG 2 BLEED pushbutton switch is released (the OFF legend is on).
       2 Make sure that the APU BLEED pushbutton switch is released (the ON legend is off).
       3 Make sure that the X BLEED selector switch is in the SHUT position.
   (3) Remove the engine bleed-air duct as follows:
     (a) On the ECAM control panel, push the BLEED key:
       1 On the SD, the BLEED page comes into view.
       2 On the BLEED page, do a check of:
  • The pressure value in the duct that reads the bleed pressure sensor
  • The temperature value in the duct that reads the bleed temperature sensor.
     (b) When the pressure and temperature values in the duct are almost the same as the external pressure and temperature:
       1 Remove the bleed air duct from the PRV (4000HA1) of engine 1 (Ref. AMM TASK 36-11-49-000-042) and (Ref. AMM TASK 36-11-49-000-043).
   (4) Point the bleed-air joint duct away from the engine and the electrical cables or equipment.
NOTE: The open end of the bleed-air joint duct points in the direction where the hot bleed air is released freely to the atmosphere.
   (5) Put a COVER - PROTECTION on the open end of the PRV (4000HA1).
   (6) Put the BLANKET - HEAT ISOLATION on the adjacent electrical cables and components.
Subtask 36-11-00-480-162-K
DELETED
4. Procedure
Subtask 36-11-00-615-067-A ** ON A/C NOT FOR ALL
A. Cleaning of the Odor Smell in the Bleed-Air Ducting System
WARNING: MAKE SURE THAT WHEN THE ENGINES OPERATE ON THE GROUND:
  • NO PERSONS GO WHERE THE AIRCRAFT CAN CAUSE THEM INJURY OR CAN KILL THEM
  • NO OBJECTS STAY WHERE THE ENGINES CAN BLOW THEM AWAY OR WHERE THEY CAN BE PULLED INTO THE ENGINES BY SUCTION.
   (1) In the cockpit, on AIR COND panel 30VU:
     (a) Set the ENG 2 BLEED pushbutton switch to the pushed position (the OFF legend is off).
     (b) Set the X BLEED selector switch to the OPEN position.
   (2) On the ECAM control panel, push the BLEED key:
     (a) On the SD, the BLEED page comes into view.
     (b) The BLEED page shows that the X BLEED valve is OPEN.
   (3) On the ECAM display, make sure that the engine bleed temperature is 225 -15 deg.C or +10 deg.C (437 -27 deg.F or +18 deg.F):
     (a) If necessary, slowly push the ENGINE-2 thrust lever to make the engine bleed temperature to 225 -15 deg.C or +10 deg.C (437 -27 deg.F or +18 deg.F). Do not reach more than 40% of N1.
   (4) Wait for a minimum of 15 minutes.
   (5) The ECAM control panel can show unusual BLEED and pack fault messages.
NOTE: The system operates correctly and it is not necessary to do the related troubleshooting procedure at this step.
   (6) Slowly pull ENGINE-2 thrust lever to the idle position.
   (7) In the cockpit, on AIR COND panel 30VU:
     (a) Set the ENG 2 BLEED pushbutton switch to the released position (the OFF legend is on).
     (b) Set the X BLEED selector switch to the AUTO position.
   (8) Stop engine 2 (Ref. AMM TASK 71-00-00-710-028).
Subtask 36-11-00-615-067-B ** ON A/C NOT FOR ALL
A. Cleaning of the Odor Smell in the Bleed-Air Ducting System
WARNING: MAKE SURE THAT WHEN THE ENGINES OPERATE ON THE GROUND:
  • NO PERSONS GO WHERE THE AIRCRAFT CAN CAUSE THEM INJURY OR CAN KILL THEM
  • NO OBJECTS STAY WHERE THE ENGINES CAN BLOW THEM AWAY OR WHERE THEY CAN BE PULLED INTO THE ENGINES BY SUCTION.
   (1) In the cockpit, on AIR COND panel 30VU:
     (a) Set the ENG 2 BLEED pushbutton switch to the pushed position (the OFF legend is off).
     (b) Set the X BLEED selector switch to the OPEN position.
   (2) On the ECAM control panel, push the BLEED key:
     (a) On the SD, the BLEED page comes into view.
     (b) The BLEED page shows that the X BLEED valve is OPEN.
   (3) On the ECAM display, make sure that the engine bleed temperature is 225 -15 deg.C or +10 deg.C (437 -27 deg.F or +18 deg.F):
     (a) If necessary, slowly push the ENGINE-2 thrust lever to make the engine bleed temperature to 225 -15 deg.C or +10 deg.C (437 -27 deg.F or +18 deg.F). Do not reach more than 40% of N1.
   (4) Wait for a minimum of 15 minutes.
   (5) The ECAM control panel can show unusual BLEED and pack fault messages.
NOTE: The system operates correctly and it is not necessary to do the related troubleshooting procedure at this step.
   (6) Slowly pull ENGINE-2 thrust lever to the idle position.
   (7) In the cockpit, on AIR COND panel 30VU:
     (a) Set the ENG 2 BLEED pushbutton switch to the released position (the OFF legend is on).
     (b) Set the X BLEED selector switch to the AUTO position.
   (8) Stop engine 2 (Ref. AMM TASK 71-00-00-710-018).
Subtask 36-11-00-615-067-D ** ON A/C NOT FOR ALL
A. Cleaning of the Odor Smell in the Bleed-Air Ducting System
WARNING: MAKE SURE THAT WHEN THE ENGINES OPERATE ON THE GROUND:
  • NO PERSONS GO WHERE THE AIRCRAFT CAN CAUSE THEM INJURY OR CAN KILL THEM
  • NO OBJECTS STAY WHERE THE ENGINES CAN BLOW THEM AWAY OR WHERE THEY CAN BE PULLED INTO THE ENGINES BY SUCTION.
   (1) In the cockpit, on AIR COND panel 30VU:
     (a) Set the ENG 2 BLEED pushbutton switch to the pushed position (the OFF legend is off).
     (b) Set the X BLEED selector switch to the OPEN position.
   (2) On the ECAM control panel, push the BLEED key:
     (a) On the SD, the BLEED page comes into view.
     (b) The BLEED page shows that the X BLEED valve is OPEN.
   (3) On the ECAM display, make sure that the engine bleed temperature is 225 -15 deg.C or +10 deg.C (437 -27 deg.F or +18 deg.F):
     (a) If necessary, slowly push the ENGINE-2 thrust lever to make the engine bleed temperature to 225 -15 deg.C or +10 deg.C (437 -27 deg.F or +18 deg.F). Do not reach more than 40% of N1.
   (4) Wait for a minimum of 15 minutes.
   (5) The ECAM control panel can show abnormal BLEED and pack fault messages.
NOTE: The system operates correctly and it is not necessary to do the related troubleshooting procedure at this step.
   (6) Slowly pull ENGINE-2 thrust lever to the idle position.
   (7) In the cockpit, on AIR COND panel 30VU:
     (a) Set the ENG 2 BLEED pushbutton switch to the released position (the OFF legend is on).
     (b) Set the X BLEED selector switch to the AUTO position.
   (8) Stop engine 2 (Ref. AMM TASK 71-00-00-710-028).
5. Close-up
Subtask 36-11-00-080-139-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the BLANKET - HEAT ISOLATION from the adjacent electrical cables and components.
   (3) Remove the COVER - PROTECTION from the open end of the PRV (4000HA1).
   (4) Install the bleed air duct in the PRV (4000HA1) of engine 1 (Ref. AMM TASK 36-11-49-400-001) and (Ref. AMM TASK 36-11-49-400-040).
   (5) Remove the SBE2272 TCT 230 DEG CELCIUS - BLEED (Ref. AMM TASK 36-11-43-000-001).
   (6) Install the FAV control thermostat (Ref. AMM TASK 36-11-43-400-001).
Subtask 36-11-00-080-139-B ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the BLANKET - HEAT ISOLATION from the adjacent electrical cables and components.
   (3) Remove the COVER - PROTECTION from the open end of the PRV (4000HA1).
   (4) Install the bleed air duct in the PRV (4000HA1) of engine 1 (Ref. AMM TASK 36-11-49-400-010).
   (5) Remove the SBE2272 TCT 230 DEG CELCIUS - BLEED (Ref. AMM TASK 36-11-43-000-001).
   (6) Install the FAV control thermostat (Ref. AMM TASK 36-11-43-400-001).
Subtask 36-11-00-080-139-D ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the BLANKET - HEAT ISOLATION from the adjacent electrical cables and components.
   (3) Remove the COVER - PROTECTION from the open end of the PRV (4000HA1).
   (4) Install the bleed air duct in the PRV (4000HA1) of engine 1 (Ref. AMM TASK 36-11-49-400-042) and (Ref. AMM TASK 36-11-49-400-043).
   (5) Remove the SBE2272 TCT 230 DEG CELCIUS - BLEED (Ref. AMM TASK 36-11-43-000-001).
   (6) Install the FAV control thermostat (Ref. AMM TASK 36-11-43-400-001).
Subtask 36-11-00-080-139-K
DELETED
Subtask 36-11-00-865-257-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
Subtask 36-11-00-790-085-A ** ON A/C NOT FOR ALL
C. Leak Test
   (1) Do a leak test of the bleed-air ducting system (Ref. AMM TASK 36-11-00-720-005).
Subtask 36-11-00-710-080-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Do an operational test of the flow control and indicating system (Ref. AMM TASK 21-51-00-710-002).
Subtask 36-11-00-860-260-A ** ON A/C NOT FOR ALL
E. Aircraft Maintenance Configuration
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (3) De-energize the aircraft electrical circuits supplied from the external power (Ref. AMM TASK 24-41-00-862-002).
   (4) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 01:06:00 UTC