Reactivation of the Bleed Pressure-Regulator Valve
TASK 36-11-00-440-806-A
Reactivation of the Bleed Pressure-Regulator Valve
MMEL 36-11-02A
ENGINE BLEED VALVE (PRV)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-150-A
Subtask 36-11-00-440-112-A
Subtask 36-11-00-410-178-A
[Rev.10 from 2021]
2026.04.01 01:06:39 UTC
Reactivation of the Bleed Pressure-Regulator Valve
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING:
YOU MUST NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE AN INJURY.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
MMEL 36-11-02A
ENGINE BLEED VALVE (PRV)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.357500) | NEVERSEEZ REGULAR GRADE |
| (Material No.357700) | NEVER-SEEZ PURE NICKEL SPECIAL |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
| TASK 78-36-00-410-806-A | Closing of the Thrust Reverser Cowl Doors |
Subtask 36-11-00-861-150-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(1) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
Subtask 36-11-00-941-148-A (Ref. AMM TASK 24-41-00-861-002).
(1) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
B. Safety Precautions
(1) Make sure that the ENG 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On AIR COND panel 30VU:
Subtask 36-11-00-865-142-A (1) Make sure that the ENG 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on)
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off)
- Put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) to tell persons not to start engine 1(2).
- Put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
- Put a WARNING NOTICE(S) to tell persons not to energize FADEC 1(2).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-00-010-189-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
D. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
Subtask 36-11-00-010-190-A (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
E. Open the right thrust-reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(1) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
452AR
(2) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
462AR.
(3) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
4. Procedure(1) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
452AR
(2) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
462AR.
(3) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
Subtask 36-11-00-440-112-A
A. Reactivation of the Bleed Pressure-Regulator Valve (PRV) (4001HA)
(a) Make sure the manual override control is in the CLOSED position:
1 Use a WRENCH - HEXAGONAL to loosen the locking pin (1) from the manual override control in the PRV (4001HA).
(b) Remove the locking pin (1) from the manual override control to unlock the valve.
(c) Install the locking pin (1) as follows:
2 Install the locking pin (1) in its storage port in the PRV (4001HA) with a WRENCH - HEXAGONAL.
3 TORQUE the locking pin (1) to between 0.5 and 0.4 m.daN (44.25 and 35.40 lbf.in )
.
5. Close-upWARNING:
DO NOT TOUCH THE BLEED VALVE COMPONENTS FOR A SHORT TIME AFTER THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS STAY HOT FOR SOME TIME AND CAN CAUSE INJURY.
(1) On the PRV (4001HA): (a) Make sure the manual override control is in the CLOSED position:
1 Use a WRENCH - HEXAGONAL to loosen the locking pin (1) from the manual override control in the PRV (4001HA).
(b) Remove the locking pin (1) from the manual override control to unlock the valve.
(c) Install the locking pin (1) as follows:
CAUTION:
BEFORE YOU INSTALL THE LOCKING PIN OR SAFETY SCREW OR SPECIAL SCREW OR KNURLED SCREW, YOU MUST APPLY NEVER-SEEZ REGULAR GRADE. IF YOU DO NOT APPLY IT, YOU CAN CAUSE DAMAGE TO THE MANUAL OVERRIDE CONTROL OF THE VALVE.
1 Apply NEVERSEEZ REGULAR GRADE (Material No.357500) or NEVER-SEEZ PURE NICKEL SPECIAL (Material No.357700) on the locking pin (1).2 Install the locking pin (1) in its storage port in the PRV (4001HA) with a WRENCH - HEXAGONAL.
3 TORQUE the locking pin (1) to between 0.5 and 0.4 m.daN (44.25 and 35.40 lbf.in )
. Subtask 36-11-00-410-178-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the right thrust-reverser cowl doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
462AR.
Subtask 36-11-00-410-179-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the right thrust-reverser cowl doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
462AR.
B. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
Subtask 36-11-00-865-143-A (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Remove the WARNING NOTICE(S).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-11-00-440-114-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | AIR BLEED/ENG 2/MONG | 3HA2 | D12 |
| 49VU | AIR BLEED/ENG 1/CTL | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 1/MONG | 3HA1 | Z23 |
| 122VU | AIR BLEED/ENG 2/CTL | 2HA2 | Z22 |
D. Reactivation of the Bleed Pressure-Regulator Valve
(1) On the ECAM control panel, push the BLEED key (on the lower ECAM DU, the BLEED page comes into view).
(a) On the lower ECAM DU, on the BLEED page:
Subtask 36-11-00-860-140-A Subtask 36-11-00-862-133-A (1) On the ECAM control panel, push the BLEED key (on the lower ECAM DU, the BLEED page comes into view).
(a) On the lower ECAM DU, on the BLEED page:
- Make sure that the related bleed-valve symbol shows closed in green.
Bleed Pressure-Regulator Valve