W DOC AIRBUS | AMM A320F

Check of the CFDS to Make Sure that the Pylon Leak Detection and APU Leak Detection Operates Correctly


TASK 36-11-00-040-004-A
Check of the CFDS to Make Sure that the Pylon Leak Detection and APU Leak Detection Operates Correctly


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.30.31
1. Reason for the Job
MMEL 36-00-01A
AIR BLEED MAINTENANCE MESSAGE
MMEL 36-00-01A
AIR BLEED MAINTENANCE MESSAGE
MMEL 36-00-01D
AIR BLEED MAINTENANCE MESSAGE
MMEL 36-00-01D
AIR BLEED MAINTENANCE MESSAGE
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 36-11-00-740-001-A
BITE Test of the BMC 1(2)
3. Job Set-up
Subtask 36-11-00-861-084-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-00-865-084-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/X FEED/VALVE/BAT2HVD13
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
122VUAIR BLEED/X FEED VALVE/NORM1HVZ20
Subtask 36-11-00-860-075-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the AIR COND panel:
  • Make sure that the ENG 1(2) BLEED pushbutton switches are pushed (OFF legends are off).
  • Make sure that the crossbleed selector switch is at AUTO position.
  • Make sure that the APU BLEED pushbutton switch is released (ON legend is off).
4. Procedure
Subtask 36-11-00-040-064-A ** ON A/C NOT FOR ALL
A. Check of the CFDS to Make Sure that the Pylon Leak Detection Operates Correctly
   (1) Do the BITE test of the BMC1 and BMC2 and print each TEST RESULT page (Ref. AMM TASK 36-11-00-740-001).
   (2) Make sure that the TEST RESULT pages do not show these maintenance messages:
ATA
MESSAGE
CLASS FAULT
361100
CHECK BMC1
2
361100
NO DATA FROM BMC2
2
361100
CHECK BMC2
2
361100
NO DATA FROM BMC1
2
361134
BMC1
2
361134
BMC2
2
362215
ENG1 PYLON LOOP INOP
2
362215
ENG2 PYLON LOOP INOP
2
362217
APU LOOP INOP OR BMC IDENT CKT
2
Subtask 36-11-00-040-064-B ** ON A/C NOT FOR ALL
A. Check of the CFDS to Make Sure that the Pylon Leak Detection Operates Correctly
   (1) Do the BITE test of the BMC1 and BMC2 and print each TEST RESULT page (Ref. AMM TASK 36-11-00-740-001).
   (2) Make sure that the TEST RESULT pages do not show this maintenance message:
ATA
MESSAGE
CLASS FAULT
362217
APU LOOP INOP OR BMC IDENT CKT
2
5. Close-up
Subtask 36-11-00-862-079-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 01:06:25 UTC