Deactivation of the HP Bleed Valve (HPV)
TASK 36-11-00-040-003-A
Deactivation of the HP Bleed Valve (HPV)
MMEL 36-11-07B
ENGINE BLEED HP VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-00-861-067-A ** ON A/C NOT FOR ALL Subtask 36-11-00-860-077-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-040-058-A ** ON A/C NOT FOR ALL
Subtask 36-11-00-410-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:06:23 UTC
Deactivation of the HP Bleed Valve (HPV)
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
FIN: 1000EM1 ** ON A/C NOT FOR ALL
FIN: 1000EM2 ** ON A/C NOT FOR ALL
FIN: 4000HA ** ON A/C NOT FOR ALL
Task Summary
1. Reason for the JobFIN: 1000EM2 ** ON A/C NOT FOR ALL
FIN: 4000HA ** ON A/C NOT FOR ALL
Task Summary
| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| YES | YES | NO | 2.4 | 2.4 | 1 |
MMEL 36-11-07B
ENGINE BLEED HP VALVE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL | |
| 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL | |
| 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 71-13-00-010-010-A | Opening of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-010-A | Closing of the Fan Cowls 437AL(447AL),438AR(448AR) |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-32-00-010-010-A | Opening of the Thrust Reverser Halves |
| TASK 78-32-00-410-010-A | Closing of the Thrust Reverser Halves |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-010-040-B | Opening of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-A | Closing of the Thrust Reverser Doors |
| TASK 78-36-00-410-040-B | Closing of the Thrust Reverser Doors |
Subtask 36-11-00-861-067-A ** ON A/C NOT FOR ALL Subtask 36-11-00-860-077-A ** ON A/C NOT FOR ALL
B. Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 36-11-00-941-068-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 31-60-00-860-001).
C. Safety Precautions
(1) Make sure that the engine 1(2) is shut down occurred not less than 5 minutes.
(2) On the AIR COND panel 30VU:
Subtask 36-11-00-865-071-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) is shut down occurred not less than 5 minutes.
(2) On the AIR COND panel 30VU:
- Make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on)
- Make sure that the APU BLEED pushbutton switch is released (the ON legend is off)
- Put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
- Put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
- Make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off
- Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
D. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-00-010-056-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
E. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
Subtask 36-11-00-040-054-A ** ON A/C NOT FOR ALL Subtask 36-11-00-010-075-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
G. Open the left thrust-reverser cowl door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-010-056-B ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
H. Get Access
(1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in to position below the engine.
Subtask 36-11-00-040-054-B ** ON A/C NOT FOR ALL (1) Open the fan cowls (Ref. AMM TASK 71-13-00-010-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in to position below the engine.
I. Deactivate the Thrust Reverser
Subtask 36-11-00-010-075-B ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER HYDRAULIC CONTROL UNIT (HCU) IS DEACTIVATED BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF THE HCU IS NOT DEACTIVATED, THERE IS A RISK OF UNWANTED THRUST REVERSER OPERATION WHICH CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Ref. AMM TASK 78-30-00-040-012). J. Open the thrust reverser halves (Ref. AMM TASK 78-32-00-010-010):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-010-056-C ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
K. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
Subtask 36-11-00-040-054-C ** ON A/C NOT FOR ALL Subtask 36-11-00-010-075-C ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the engine.
M. Open the left thrust-reverser cowl door (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL
(2) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-040-058-A ** ON A/C NOT FOR ALL
A. Deactivation of the HPV
HP Bleed Valve P/N 6713D01-07 ** ON A/C NOT FOR ALL
HP Bleed Valve P/N 6713D01-07 ** ON A/C NOT FOR ALL
(a) Use a WRENCH - HEXAGONAL to set the manual override control to the CLOSED position.
(c) Remove the knurled screw (1), the connecting cable and the washer (2) from the storage port:
1 Safety the connecting cable to HPV.
2 Keep the washer (2) to install it in the reactivation procedure.
(d) Lock the override control with the knurled screw (1).
(2) Do the steps that follow for HPV PN 6773B03 and PN 6713D08:
(a) Use a WRENCH - HEXAGONAL to set the manual override control to the CLOSED position.
(c) Remove the safety screw (1), the connecting cable and the washer (2) from the storage port:
1 Safety the connecting cable to HPV.
2 Keep the washer (2) to install it in the reactivation procedure.
(d) Lock the override control with the safety screw (1).
.
(3) Do the steps that follow for HPV PN 6773E:
(a) Use a WRENCH - HEXAGONAL to set the manual override control to the CLOSED position.
(c) Remove the special screw (1), the connecting cable and the washer (2) from the storage port:
1 Safety the connecting cable to HPV.
2 Keep the washer (2) to install it in the reactivation procedure.
(d) Remove and discard the packing (3).
(e) Lock the override control with the special screw (1).
(4) Do the steps that follow for HPV PN 6773F and PN 6773G:
HP Bleed Valve P/N 6773F and 6773G ** ON A/C NOT FOR ALL
HP Bleed Valve P/N 6773F and 6773G ** ON A/C NOT FOR ALL
(a) Use a WRENCH - HEXAGONAL to set the manual override control to the CLOSED position.
(c) Remove the safety screw (1) and the connecting cable from the storage port:
1 Safety the connecting cable to HPV.
(d) Remove and discard the packing (2).
(e) Lock the override control with the safety screw (1).
.
Subtask 36-11-00-865-085-A ** ON A/C NOT FOR ALL CAUTION:
CAREFULLY ALIGN THE LOCKING PIN WITH THE DEACTIVATING HOUSING ON THE VALVE. IF YOU ALIGN IT INCORRECTLY OR IF YOU TIGHTEN IT TOO MUCH, THE LOCKING PIN CAN REMAIN IN POSITION AND YOU CAN CAUSE DAMAGE TO THE LOCKING PIN THREAD.
(1) Do the steps that follow for HPV Part Number (PN) 6773B02 and PN 6713D01 to 6713D07:
HP Bleed Valve P/N 6713D01-07 ** ON A/C NOT FOR ALL
HP Bleed Valve P/N 6713D01-07 ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(b) Cut, remove and discard the lockwire from the knurled screw (1).(c) Remove the knurled screw (1), the connecting cable and the washer (2) from the storage port:
1 Safety the connecting cable to HPV.
2 Keep the washer (2) to install it in the reactivation procedure.
(d) Lock the override control with the knurled screw (1).
NOTE: The pressure of the valve is released when you remove the locking pin from its storage port.
(e) Tighten the knurled screw (1) with your hand. (2) Do the steps that follow for HPV PN 6773B03 and PN 6713D08:
(a) Use a WRENCH - HEXAGONAL to set the manual override control to the CLOSED position.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(b) Cut, remove and discard the lockwire from the safety screw (1). (c) Remove the safety screw (1), the connecting cable and the washer (2) from the storage port:
1 Safety the connecting cable to HPV.
2 Keep the washer (2) to install it in the reactivation procedure.
(d) Lock the override control with the safety screw (1).
NOTE: The pressure of the valve is released when you remove the locking pin from its storage port.
(e) TORQUE the safety screw (1) to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in )
. (3) Do the steps that follow for HPV PN 6773E:
(a) Use a WRENCH - HEXAGONAL to set the manual override control to the CLOSED position.
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(b) Cut, remove and discard the lockwire from the special screw (1). (c) Remove the special screw (1), the connecting cable and the washer (2) from the storage port:
1 Safety the connecting cable to HPV.
2 Keep the washer (2) to install it in the reactivation procedure.
(d) Remove and discard the packing (3).
(e) Lock the override control with the special screw (1).
NOTE: The pressure of the valve is released when you remove the locking pin from its storage port.
(f) Tighten the special screw (1) with your hand. (4) Do the steps that follow for HPV PN 6773F and PN 6773G:
HP Bleed Valve P/N 6773F and 6773G ** ON A/C NOT FOR ALL
HP Bleed Valve P/N 6773F and 6773G ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(b) Cut, remove and discard the lockwire from the safety screw (1). (c) Remove the safety screw (1) and the connecting cable from the storage port:
1 Safety the connecting cable to HPV.
(d) Remove and discard the packing (2).
(e) Lock the override control with the safety screw (1).
NOTE: The pressure of the valve is released when you remove the locking pin from its storage port.
(f) TORQUE the safety screw (1) to between 0.6 and 0.5 m.daN (53.10 and 44.25 lbf.in )
.B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 36-11-00-040-078-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
C. Deactivation of the HP Bleed Valve
(1) On the ECAM control panel, push the BLEED key (on the lower ECAM DU, the BLEED page comes into view).
(a) On the lower ECAM DU, on the BLEED page:
1 Make sure that the related HP bleed-valve symbol shows closed in green.
2 Make sure that the related bleed-pressure regulator-valve symbol shows closed in green.
5. Close-up(1) On the ECAM control panel, push the BLEED key (on the lower ECAM DU, the BLEED page comes into view).
(a) On the lower ECAM DU, on the BLEED page:
1 Make sure that the related HP bleed-valve symbol shows closed in green.
2 Make sure that the related bleed-pressure regulator-valve symbol shows closed in green.
Subtask 36-11-00-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-055-A ** ON A/C NOT FOR ALL Subtask 36-11-00-410-075-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
C. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 36-11-00-410-056-B ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
D. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
Subtask 36-11-00-440-055-B ** ON A/C NOT FOR ALL Subtask 36-11-00-410-075-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser halves (Ref. AMM TASK 78-32-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(b) FOR [1000EM2] (ENGINE-2)
461AL 462AR.
F. Close Access
(1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
Subtask 36-11-00-410-056-C ** ON A/C NOT FOR ALL (1) Close the fan cowls (Ref. AMM TASK 71-13-00-410-010):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
G. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
Subtask 36-11-00-440-055-C ** ON A/C NOT FOR ALL Subtask 36-11-00-410-075-C ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl door (Ref. AMM TASK 78-36-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
451AL
(b) FOR [1000EM2] (ENGINE-2)
461AL.
I. Close Access
(1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Subtask 36-11-00-860-079-A ** ON A/C NOT FOR ALL Subtask 36-11-00-869-115-A ** ON A/C NOT FOR ALL (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
K. Make an entry in the logbook.
Subtask 36-11-00-862-067-A ** ON A/C NOT FOR ALL