Removal of the Low-Pressure Oxygen-Supply Solenoid-Valves
TASK 35-13-51-000-802-A
Removal of the Low-Pressure Oxygen-Supply Solenoid-Valves
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 35-13-51-010-051-A ** ON A/C NOT FOR ALL
Subtask 35-13-51-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:04:47 UTC
Removal of the Low-Pressure Oxygen-Supply Solenoid-Valves
WARNING:
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
CAUTION:
PUT DRY AND CLEAN METAL OR PLASTIC PLUGS ON ALL PIPES OR UNITS THAT YOU REMOVE TEMPORARILY. THEN PUT EACH PIPE OR UNIT IN A SEALED VINYL BAG. IF YOU DO NOT OBEY THESE INSTRUCTIONS, CONTAMINATION OF THE OXYGEN SYSTEM CAN OCCUR.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| FOR [3HT1] (LP SOLENOID SUPPLY VALVE) | ||
| No specific | AR | BAG - VINYL |
| No specific | AR | BAG - VINYL, SEALED |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN |
| FOR [3HT2] (LP SOLENOID SUPPLY VALVE) | ||
| No specific | AR | BAG - VINYL |
| No specific | AR | BAG - VINYL, SEALED |
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 123 | NOSE GEAR WELL |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
Subtask 35-13-51-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(3) Open access door 812.
Subtask 35-13-51-860-053-A ** ON A/C NOT FOR ALL (1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position at access door 812.
(3) Open access door 812.
B. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
(4) Put a WARNING NOTICE(S) in position to tell persons not to open the manual-shutoff valves of the crew oxygen-storage cylinders 5750HM1 and 5750HM2.
Subtask 35-13-51-870-051-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
- Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
(4) Put a WARNING NOTICE(S) in position to tell persons not to open the manual-shutoff valves of the crew oxygen-storage cylinders 5750HM1 and 5750HM2.
C. Bleeding of the Oxygen Systems
(1) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator.
(a) Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
(3) On the First-Officer oxygen-mask stowage-box, push and hold the PRESS TO TEST AND RESET control button.
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator.
(a) Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
(4) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
Subtask 35-13-51-865-054-A ** ON A/C NOT FOR ALL (1) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
- Push the CREW SUPPLY pushbutton switch (the OFF legend goes off).
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator.
(a) Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and the volume of the sound of the oxygen flow decreases.
(b) When the flow rate indicator is black and when you no longer hear the sound of the oxygen flow: - Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control button.
WARNING:
MAKE SURE THAT THE PRESS TO TEST/EMERGENCY KNOB IS NOT IN THE EMERGENCY POSITION. IF IT IS IN THE EMERGENCY POSITION, THERE CAN BE A LEAK OF OXYGEN.
1 Make sure that the PRESS TO TEST/EMERGENCY knob is not in the emergency position. (3) On the First-Officer oxygen-mask stowage-box, push and hold the PRESS TO TEST AND RESET control button.
At the same time, push and hold the PRESS TO TEST/EMERGENCY knob on the mask regulator.
(a) Keep the PRESS TO TEST AND RESET control button and the PRESS TO TEST/EMERGENCY knob pushed for a minimum of three seconds.
NOTE: During this time, the flow rate indicator changes from yellow to black and the volume of the sound of the oxygen flow decreases.
(b) When the flow rate indicator is black and when you no longer hear the sound of the oxygen flow: - Release the PRESS TO TEST/EMERGENCY knob.
- Release the PRESS TO TEST AND RESET control button.
WARNING:
MAKE SURE THAT THE PRESS TO TEST/EMERGENCY KNOB IS NOT IN THE EMERGENCY POSITION. IF IT IS IN THE EMERGENCY POSITION, THERE CAN BE A LEAK OF OXYGEN.
1 Make sure that the PRESS TO TEST/EMERGENCY knob is not in the emergency position. (4) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
- Release the CREW SUPPLY pushbutton switch (the OFF legend comes on).
D. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
Subtask 35-13-51-020-051-A ** ON A/C NOT FOR ALL
A. Removal of LP Oxygen-Supply Solenoid-Valves 3HT1 and/or 3HT2
(a) Disconnect the electrical connector (3HT1A) (6) from the LP oxygen-supply solenoid-valve (3HT1) (5).
(b) Put a CAP - BLANKING on the disconnected electrical connector (3HT1A) (6).
(c) Disconnect the flexible pipe (8) and discard the bush (7).
(d) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the flexible pipe (8).
(e) Put a BAG - VINYL around the disconnected flexible pipe (8).
(f) Disconnect the pipe (3) from the union (10) and from the LP oxygen-supply solenoid-valve (3HT1) (5).
(g) Remove the pipe (3) and discard the bushes (4) and (11).
(h) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on each end of the pipe (3).
(i) Put the pipe (3) in a BAG - VINYL.
(j) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (10).
(k) Put the union (10) in a BAG - VINYL.
(l) Remove the screws (2), washers (1), nuts (9) and the LP oxygen-supply solenoid-valve (3HT1) (5).
(m) Put the LP oxygen-supply solenoid-valve (3HT1) (5) in a BAG - VINYL, SEALED.
(2) FOR [3HT2] (LP SOLENOID SUPPLY VALVE)
(a) Disconnect the electrical connector (3HT2A) (19) from the LP oxygen-supply solenoid-valve (3HT2) (18).
(b) Put a CAP - BLANKING on the disconnected electrical connector (3HT2A) (19).
(c) Disconnect the rigid pipe (16) from the union (14) and from the LP oxygen-supply solenoid-valve (3HT2) (18).
(d) Remove the rigid pipe (16) and discard the bushes (17) and (15).
(e) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on each end of the rigid pipe (16).
(f) Put the rigid pipe (16) in a BAG - VINYL.
(g) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (14).
(h) Put the union (14) in a BAG - VINYL.
(i) Disconnect the pipe (21) from the union (24) and from the LP oxygen-supply solenoid-valve (3HT2) (18).
(j) Remove the pipe (21) and discard the bushes (20) and (23).
(k) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on each end of the pipe (21).
(l) Put the pipe (21) in a BAG - VINYL.
(m) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (24).
(n) Put the union (24) in a BAG - VINYL.
(o) Remove the screws (12), washers (13), nuts (22) and the LP oxygen-supply solenoid-valve (3HT2) (18).
(p) Put the LP oxygen-supply solenoid-valve (3HT2) (18) in a BAG - VINYL, SEALED.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN YOU DISCONNECT/CONNECT EQUIPMENT FROM FLEXIBLE HOSES AND RIGID TUBING.
IF YOU DO NOT USE THE SECOND WRENCH, THERE IS A RISK THAT YOU WILL CAUSE DAMAGE TO THE HOSES AND TUBES.
(1) FOR [3HT1] (LP SOLENOID SUPPLY VALVE)(a) Disconnect the electrical connector (3HT1A) (6) from the LP oxygen-supply solenoid-valve (3HT1) (5).
(b) Put a CAP - BLANKING on the disconnected electrical connector (3HT1A) (6).
(c) Disconnect the flexible pipe (8) and discard the bush (7).
(d) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the flexible pipe (8).
(e) Put a BAG - VINYL around the disconnected flexible pipe (8).
(f) Disconnect the pipe (3) from the union (10) and from the LP oxygen-supply solenoid-valve (3HT1) (5).
(g) Remove the pipe (3) and discard the bushes (4) and (11).
(h) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on each end of the pipe (3).
(i) Put the pipe (3) in a BAG - VINYL.
(j) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (10).
(k) Put the union (10) in a BAG - VINYL.
(l) Remove the screws (2), washers (1), nuts (9) and the LP oxygen-supply solenoid-valve (3HT1) (5).
(m) Put the LP oxygen-supply solenoid-valve (3HT1) (5) in a BAG - VINYL, SEALED.
(2) FOR [3HT2] (LP SOLENOID SUPPLY VALVE)
(a) Disconnect the electrical connector (3HT2A) (19) from the LP oxygen-supply solenoid-valve (3HT2) (18).
(b) Put a CAP - BLANKING on the disconnected electrical connector (3HT2A) (19).
(c) Disconnect the rigid pipe (16) from the union (14) and from the LP oxygen-supply solenoid-valve (3HT2) (18).
(d) Remove the rigid pipe (16) and discard the bushes (17) and (15).
(e) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on each end of the rigid pipe (16).
(f) Put the rigid pipe (16) in a BAG - VINYL.
(g) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (14).
(h) Put the union (14) in a BAG - VINYL.
(i) Disconnect the pipe (21) from the union (24) and from the LP oxygen-supply solenoid-valve (3HT2) (18).
(j) Remove the pipe (21) and discard the bushes (20) and (23).
(k) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on each end of the pipe (21).
(l) Put the pipe (21) in a BAG - VINYL.
(m) Put a PLUG - BLANKING, APPROVED FOR USE WITH OXYGEN on the union (24).
(n) Put the union (24) in a BAG - VINYL.
(o) Remove the screws (12), washers (13), nuts (22) and the LP oxygen-supply solenoid-valve (3HT2) (18).
(p) Put the LP oxygen-supply solenoid-valve (3HT2) (18) in a BAG - VINYL, SEALED.
Low-Pressure Oxygen-Supply Solenoid-Valve