Removal of the Oxygen Filling Indicator
TASK 35-13-21-000-001-A
Removal of the Oxygen Filling Indicator
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 35-13-21-010-050-A
Subtask 35-13-21-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:04:36 UTC
Removal of the Oxygen Filling Indicator
WARNING:
KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING:
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
ZONE: 123
ZONE: 125
FIN: 5HT ** ON A/C NOT FOR ALL
FIN: 5HT1 ** ON A/C NOT FOR ALL
FIN: 5HT2 ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 125
FIN: 5HT ** ON A/C NOT FOR ALL
FIN: 5HT1 ** ON A/C NOT FOR ALL
FIN: 5HT2 ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | BAG - VINYL, SEALED |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 123 | NOSE GEAR WELL |
| 125 | LATERAL AVIONIC COMPARTMENT |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 35-00-00-860-001-A | Special Precautions When Working on a Gaseous Oxygen System |
Subtask 35-13-21-010-050-A
A. Get Access
(1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position below access door 812.
(3) Open access door 812.
Subtask 35-13-21-860-050-A (1) Obey the special precautions when you do work on a gaseous oxygen system (Ref. AMM TASK 35-00-00-860-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) in position below access door 812.
(3) Open access door 812.
B. Aircraft Maintenance Configuration
(1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
(2) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
Subtask 35-13-21-865-050-A (1) Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
(2) In the cockpit, on the OXYGEN section of the overhead control and indicating panel 21VU:
- Make sure that the CREW SUPPLY pushbutton switch is released (the OFF legend is on).
- Put a WARNING NOTICE(S) in position to tell persons not to push the CREW SUPPLY pushbutton switch.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | OXYGEN/CREW/OXY/SPLY | 1HT | HA01 |
Subtask 35-13-21-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Oxygen Filling Indicator.
(1) Disconnect the electrical connector (4) from the indicator (1).
(2) Put a CAP - BLANKING on the disconnected electrical connector (4).
(3) Loosen the adjusting screw (2) of the clamp (3).
(4) Remove the indicator (1) from the clamp (3).
Subtask 35-13-21-020-050-B ** ON A/C NOT FOR ALL (1) Disconnect the electrical connector (4) from the indicator (1).
(2) Put a CAP - BLANKING on the disconnected electrical connector (4).
(3) Loosen the adjusting screw (2) of the clamp (3).
(4) Remove the indicator (1) from the clamp (3).
A. Removal of the Oxygen Filling Indicator
(2) Put a CAP - BLANKING on the disconnected electrical connector (1).
(3) Loosen the adjusting screws (3) of the clamp (2).
(4) Remove the oxygen filling indicator (4) from the clamp (2) and from the support plate (5).
(5) Put the oxygen filling indicator (4) in a BAG - VINYL, SEALED.
CAUTION:
MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
(1) Disconnect the electrical connector (1) from the oxygen filling indicator (4). (2) Put a CAP - BLANKING on the disconnected electrical connector (1).
(3) Loosen the adjusting screws (3) of the clamp (2).
(4) Remove the oxygen filling indicator (4) from the clamp (2) and from the support plate (5).
(5) Put the oxygen filling indicator (4) in a BAG - VINYL, SEALED.
Oxygen Filling Indicator