W DOC AIRBUS | AMM A320F

Remove Pressure Regulator Transmitter for In Shop Functional Check


TASK 35-13-00-200-802-A
Remove Pressure Regulator Transmitter for In Shop Functional Check


WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING: CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
ZONE: 125
1. Reason for the Job
Refer to the MPD TASK: 351000-10
REMOVE PRESSURE REGULATOR TRANSMITTER FOR IN SHOP FUNCTIONAL CHECK

2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
125
LATERAL AVIONIC COMPARTMENT
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 35-13-15-000-001-A
Removal of the Oxygen Pressure Regulator/Transmitter
TASK 35-13-15-000-802-A
Removal of the Oxygen Pressure Regulator/Transmitters
TASK 35-13-15-400-001-A
Installation of the Oxygen Pressure Regulator/Transmitter
TASK 35-13-15-400-802-A
Installation of the Oxygen Pressure Regulator/Transmitters
3. Job Set-up
Subtask 35-13-00-020-051-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Remove the oxygen pressure regulator/transmitter (4HT) (Ref. AMM TASK 35-13-15-000-001).
Subtask 35-13-00-020-051-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Remove the oxygen pressure regulator/transmitters (4HT) and (4HT2) (Ref. AMM TASK 35-13-15-000-802).
4. Procedure
Subtask 35-13-00-200-051-A ** ON A/C NOT FOR ALL
A. Functional Check
   (1) Send the oxygen pressure regulator/transmitter (4HT) to the workshop for:
  • A functional check to find leaks
  • A functional check for correct pressure regulation
  • A functional check of its pressure sensor.
Subtask 35-13-00-200-051-B ** ON A/C NOT FOR ALL
A. Functional Check
   (1) Send the oxygen pressure regulator/transmitters (4HT) and (4HT2) to the workshop for:
  • A functional check to find leaks
  • A functional check for correct pressure regulation
  • A functional check of its pressure sensor.
5. Close-up
Subtask 35-13-00-420-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the serviceable oxygen-pressure regulator/transmitter (4HT) (Ref. AMM TASK 35-13-15-400-001).
Subtask 35-13-00-420-051-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Install the serviceable oxygen-pressure regulator/transmitters (4HT) and (4HT2) (Ref. AMM TASK 35-13-15-400-802).
[Rev.10 from 2021] 2026.04.01 01:04:26 UTC