W DOC AIRBUS | AMM A320F

Remove Crew Oxygen Mask for In-Shop Functional Check of Mask Regulator Assembly


TASK 35-12-41-750-001-A
Remove Crew Oxygen Mask for In-Shop Functional Check of Mask Regulator Assembly


WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, ETC.) AWAY FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE WHEN IT TOUCHES HYDROCARBONS.
WARNING: CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN SYSTEM.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE OF THE FULL-FACE/QUICK-DONNING MASK(S). YOU CAN CAUSE DAMAGE TO THIS EQUIPMENT VERY EASILY IF YOU USE TOO MUCH FORCE OR THE INCORRECT CLEANING MATERIALS.
ZONE: 210
1. Reason for the Job
Refer to the MPD TASK: 351241-02
REMOVE CREW OXYGEN MASK FOR IN SHOP FUNCTIONAL CHECK OF MASK REGULATOR ASSEMBLY

2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 35-12-41-000-002-A
Removal of the Full-Face/Quick-Donning Oxygen-Mask
TASK 35-12-41-400-002-A
Installation of the Full-Face/Quick-donning Oxygen-Mask
3. Job Set-up
Subtask 35-12-41-020-051-A
A. Get Access
   (1) Remove the full-face/quick-donning oxygen mask (Ref. AMM TASK 35-12-41-000-002).
4. Procedure
Subtask 35-12-41-720-050-A
A. Functional Check
   (1) Send the full-face/quick-donning oxygen mask to the workshop for a functional check of its regulator assembly.
5. Close-up
Subtask 35-12-41-420-050-A
A. Close Access
   (1) Install the full-face/quick-donning oxygen mask (Ref. AMM TASK 35-12-41-400-002).
[Rev.10 from 2021] 2026.04.01 01:04:15 UTC