Installation of the Remote ATC Control Box
TASK 34-52-35-400-001-A
Installation of the Remote ATC Control Box
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-52-35-860-050-A ** ON A/C NOT FOR ALL
Subtask 34-52-35-420-050-A ** ON A/C NOT FOR ALL
Subtask 34-52-35-410-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:32 UTC
Installation of the Remote ATC Control Box
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 812, 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 34-52-00-710-005-A | Operational Test of the Remote ATC Control Box |
Subtask 34-52-35-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position at the access door 824 in zone 128.
(2) Make sure that the access door 824 is open.
(3) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 812 in zone 125.
(4) Make sure that the access door 812 is open.
Subtask 34-52-35-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position at the access door 824 in zone 128.
(2) Make sure that the access door 824 is open.
(3) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 812 in zone 125.
(4) Make sure that the access door 812 is open.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM NAV/ATC/1 | 5SH1 | G11 |
| 106VU | NAV/ATC 1/EMER | 10SH | B01 |
| 121VU | COM NAV/ATC/2 | 5SH2 | K07 |
Subtask 34-52-35-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Remote ATC Control Box
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Install the Remote ATC Control Box (1) on its rack (3).
(6) Push the Remote ATC Control Box (1) on its rack (3) to connect the electrical connectors (2).
(7) Engage the nut (4) on the lug (5) and tighten.
Subtask 34-52-35-865-052-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Install the Remote ATC Control Box (1) on its rack (3).
(6) Push the Remote ATC Control Box (1) on its rack (3) to connect the electrical connectors (2).
(7) Engage the nut (4) on the lug (5) and tighten.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 34-52-35-710-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM NAV/ATC/1 | 5SH1 | G11 |
| 106VU | NAV/ATC 1/EMER | 10SH | B01 |
| 121VU | COM NAV/ATC/2 | 5SH2 | K07 |
Subtask 34-52-35-410-050-A ** ON A/C NOT FOR ALL