W DOC AIRBUS | AMM A320F

Installation of the Remote ATC Control Box


TASK 34-52-35-400-001-A
Installation of the Remote ATC Control Box


ZONE: 128
FIN: 8SH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
128
REAR AVIONIC COMPARTMENT
812, 824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 34-52-00-710-005-A
Operational Test of the Remote ATC Control Box
3. Job Set-up
Subtask 34-52-35-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position at the access door 824 in zone 128.
   (2) Make sure that the access door 824 is open.
   (3) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the access door 812 in zone 125.
   (4) Make sure that the access door 812 is open.
Subtask 34-52-35-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM NAV/ATC/15SH1G11
106VUNAV/ATC 1/EMER10SHB01
121VUCOM NAV/ATC/25SH2K07
4. Procedure
Subtask 34-52-35-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Remote ATC Control Box
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Make sure that all the electrical connections are clean and in the correct condition.
   (5) Install the Remote ATC Control Box (1) on its rack (3).
   (6) Push the Remote ATC Control Box (1) on its rack (3) to connect the electrical connectors (2).
   (7) Engage the nut (4) on the lug (5) and tighten.
Subtask 34-52-35-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM NAV/ATC/15SH1G11
106VUNAV/ATC 1/EMER10SHB01
121VUCOM NAV/ATC/25SH2K07
Subtask 34-52-35-710-050-A ** ON A/C NOT FOR ALL
C. Do the Operational Test of the Remote ATC Control Box (Ref. AMM TASK 34-52-00-710-005).
5. Close-up
Subtask 34-52-35-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 812 and the access door 824.
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:23:32 UTC