W DOC AIRBUS | AMM A320F

Removal of the Remote ATC Control Box


TASK 34-52-35-000-001-A
Removal of the Remote ATC Control Box


ZONE: 128
FIN: 8SH ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
128
REAR AVIONIC COMPARTMENT
812, 824
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 34-52-35-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 824 in zone 128.
   (2) Open the access door 824.
   (3) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 812 in zone 125.
   (4) Open the access door 812.
Subtask 34-52-35-865-050-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUCOM NAV/ATC/15SH1G11
106VUNAV/ATC 1/EMER10SHB01
121VUCOM NAV/ATC/25SH2K07
4. Procedure
Subtask 34-52-35-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Remote ATC Control Box
   (1) Loosen the nut (4).
   (2) Lower the nut (4).
   (3) Pull the Remote ATC Control Box (1) on this rack (3) to disconnect the electrical connectors (2).
   (4) Remove the Remote ATC Control Box (1) from the rack (3).
   (5) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
[Rev.10 from 2021] 2026.04.02 06:23:32 UTC