W DOC AIRBUS | AMM A320F

Removal of the DME Interrogator


TASK 34-51-33-000-001-A
Removal of the DME Interrogator


ZONE: 127
ZONE: 128
FIN: 2SD1
FIN: 2SD2
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
127
REAR AVIONIC COMPARTMENT
128
REAR AVIONIC COMPARTMENT
824
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 34-51-33-865-050-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 2SD1 (INTRGDME, 1)
49VUNAV/DME/11SD1G14
FOR FIN: 2SD2 (INTRGDME, 2)
121VUCOM NAV/DME/21SD2K06
Subtask 34-51-33-010-050-A
B. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 824 in zone 128.
   (2) Open the access door 824.
4. Procedure
Subtask 34-51-33-020-050-A
A. Removal of the DME Interrogator
   (1) Loosen the nuts (4).
   (2) Lower the nuts (4).
   (3) Pull the DME interrogator (1) on its rack (3) to disconnect the electrical connectors (2).
   (4) Remove the DME interrogator (1) from its rack (3).
   (5) Put CAP - BLANKING on the disconnected electrical connectors (2).
[Rev.10 from 2021] 2026.04.02 06:23:30 UTC