Removal of the GPWC
TASK 34-48-34-000-001-B
Removal of the GPWC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-48-34-865-059-A ** ON A/C NOT FOR ALL
Subtask 34-48-34-020-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:30 UTC
Removal of the GPWC
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
Subtask 34-48-34-865-059-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 34-48-34-010-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/GPWS/115VAC | 3WZ | P07 |
| 121VU | EIS/GPWS/28VDC | 2WZ | P06 |
B. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 824 in zone 128.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 824 in zone 128.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 34-48-34-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the GPWC
(1) Loosen the nut (4).
(2) Lower the nut (4).
(3) Pull the GPWC (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the GPWC (1) from its rack (3).
(5) Put CAP - BLANKING on the disconnected electrical connectors (2).
(1) Loosen the nut (4).
(2) Lower the nut (4).
(3) Pull the GPWC (1) on its rack (3) to disconnect the electrical connectors (2).
(4) Remove the GPWC (1) from its rack (3).
(5) Put CAP - BLANKING on the disconnected electrical connectors (2).
GPWC