BITE Test of the Enhanced EGPWS
TASK 34-48-00-740-002-D
BITE Test of the Enhanced EGPWS
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 34-48-00-860-109-A ** ON A/C NOT FOR ALL
Subtask 34-48-00-740-063-A ** ON A/C NOT FOR ALL
Subtask 34-48-00-860-110-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:29 UTC
BITE Test of the Enhanced EGPWS
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-010-A | Procedure to Get Access to the SYSTEM REPORT/TEST NAV Page |
| TASK 34-10-00-860-002-A | ADIRS Start Procedure |
| TASK 34-10-00-860-005-A | ADIRS Stop Procedure |
Subtask 34-48-00-860-109-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On the overhead control and indicating panel 21VU, on the GPWS section, make sure that the five GPWS pushbutton switches are released (legends off).
(3) On the center pedestal, on one MCDU, get access to the SYSTEM REPORT/TEST NAV page, then push the NEXT PAGE function key until the GPWC indication comes into view (Ref. AMM TASK 31-32-00-860-010).
(4) Do the ADIRS start procedure (Ref. AMM TASK 34-10-00-860-002).
(5) On the FCU, on the CAPT and F/O EFIS control panels, set the mode selector switch to ARC.
(6) On the FCU, on the CAPT and F/O EFIS control panels, set the scale selector switch to 160.
Subtask 34-48-00-865-089-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) On the overhead control and indicating panel 21VU, on the GPWS section, make sure that the five GPWS pushbutton switches are released (legends off).
(3) On the center pedestal, on one MCDU, get access to the SYSTEM REPORT/TEST NAV page, then push the NEXT PAGE function key until the GPWC indication comes into view (Ref. AMM TASK 31-32-00-860-010).
(4) Do the ADIRS start procedure (Ref. AMM TASK 34-10-00-860-002).
(5) On the FCU, on the CAPT and F/O EFIS control panels, set the mode selector switch to ARC.
(6) On the FCU, on the CAPT and F/O EFIS control panels, set the scale selector switch to 160.
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/GPWS/115VAC | 3WZ | P07 |
| 121VU | EIS/GPWS/28VDC | 2WZ | P06 |
Subtask 34-48-00-740-063-A ** ON A/C NOT FOR ALL
A. BITE Test of the Enhanced GPWC
5. Close-upNOTE: The actions and the results of this procedure occur on the MCDU used.
| ACTION | RESULT |
|---|---|
| On the MCDU, on the NAV page: | On the MCDU: |
|
|
|
|
|
|
Subtask 34-48-00-860-110-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the center pedestal, on the MCDU, push the line key adjacent to the RETURN indication until the MCDU MENU page comes into view.
(2) Do the ADIRS stop procedure (Ref. AMM TASK 34-10-00-860-005).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(4) Make sure that the work area is clean and clear of tools and other items.
(1) On the center pedestal, on the MCDU, push the line key adjacent to the RETURN indication until the MCDU MENU page comes into view.
(2) Do the ADIRS stop procedure (Ref. AMM TASK 34-10-00-860-005).
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(4) Make sure that the work area is clean and clear of tools and other items.