Uploading of the RAAS Configuration DataBase (RCD)
TASK 34-48-00-610-003-C
Uploading of the RAAS Configuration DataBase (RCD)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-48-00-800-059-A ** ON A/C NOT FOR ALL
Subtask 34-48-00-970-058-E ** ON A/C NOT FOR ALL
Subtask 34-48-00-410-060-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:29 UTC
Uploading of the RAAS Configuration DataBase (RCD)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 34-48-00-710-001-G | Operational Check of Ground Self Test System |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 34-48-00-800-059-A ** ON A/C NOT FOR ALL
A. Refer to the equipment manufacturer Service Bulletin related to the version of the RCD database that you upload.
Subtask 34-48-00-861-062-A ** ON A/C NOT FOR ALL Subtask 34-48-00-010-060-A ** ON A/C NOT FOR ALL C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 824 in zone 128.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 34-48-00-875-056-B ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) in position at the access door 824 in zone 128.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002).
D. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/GPWS/115VAC | 3WZ | P07 |
Subtask 34-48-00-970-058-E ** ON A/C NOT FOR ALL
A. Upload of the RAAS Configuration Database (RCD) with a USB mass-storage device in the Enhanced Ground Proximity Warning Computer (GPWC) Installed on the Aircraft
(2) On the front of the Enhanced GPWC, make sure that the COMPUTER STATUS LED is green.
(3) Open the door on the front of the Enhanced GPWC.
(4) Make sure that the DATALOAD STATUS LED is off.
(5) Put the USB mass-storage device in the USB port.
(6) The DATALOAD STATUS LED becomes amber during the upload.
(7) When the upload is completed, the DATALOAD STATUS LED becomes green.
(8) Remove the USB mass-storage device from the Enhanced GPWC.
(9) The Enhanced GPWC starts again.
(10) After approximately 2 seconds, the COMPUTER STATUS LED flashes approximately for 2 seconds then goes off approximately for 2 seconds.
(11) The COMPUTER STATUS LED comes on green.
(12) Do a reset of the Enhanced GPWC.
(a) Open the circuit breaker (3WZ) and wait approximately 10 seconds.
(b) Close the circuit breaker (3WZ).
(c) When the COMPUTER STATUS LED comes on green, the Enhanced GPWC can operate.
(13) Close the door on the front of the Enhanced GPWC.
(14) Put the USB mass-storage device with the RCD software in the storage box.
Subtask 34-48-00-710-088-C ** ON A/C NOT FOR ALL NOTE: To do the upload of the RAAS Configuration Database (RCD) (RAAS: Runway Awareness and Advisory System), the Enhanced GPWC terrain database must be version 468 minimum.
(1) Get the USB mass-storage device with the RCD software from the storage box. (2) On the front of the Enhanced GPWC, make sure that the COMPUTER STATUS LED is green.
(3) Open the door on the front of the Enhanced GPWC.
(4) Make sure that the DATALOAD STATUS LED is off.
(5) Put the USB mass-storage device in the USB port.
(6) The DATALOAD STATUS LED becomes amber during the upload.
(7) When the upload is completed, the DATALOAD STATUS LED becomes green.
(8) Remove the USB mass-storage device from the Enhanced GPWC.
(9) The Enhanced GPWC starts again.
(10) After approximately 2 seconds, the COMPUTER STATUS LED flashes approximately for 2 seconds then goes off approximately for 2 seconds.
(11) The COMPUTER STATUS LED comes on green.
(12) Do a reset of the Enhanced GPWC.
(a) Open the circuit breaker (3WZ) and wait approximately 10 seconds.
(b) Close the circuit breaker (3WZ).
(c) When the COMPUTER STATUS LED comes on green, the Enhanced GPWC can operate.
(13) Close the door on the front of the Enhanced GPWC.
(14) Put the USB mass-storage device with the RCD software in the storage box.
B. Do the Operational test of the enhanced GPWC (Ref. AMM TASK 34-48-00-710-001).
(1) Make sure that the last five digits of the RCD software P/N on the label of the USB Mass-Storage Device are the same as the RCD software P/N read on the CAPT or F/O ND.
5. Close-up(1) Make sure that the last five digits of the RCD software P/N on the label of the USB Mass-Storage Device are the same as the RCD software P/N read on the CAPT or F/O ND.
Subtask 34-48-00-410-060-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Subtask 34-48-00-862-061-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
Enhanced GPWC Face