Installation of the Radio Altimeter-Transceiver Fan
TASK 34-42-45-400-001-A
Installation of the Radio Altimeter-Transceiver Fan
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 34-42-45-860-050-A
Subtask 34-42-45-420-050-B
Subtask 34-42-45-410-050-A
[Rev.10 from 2021]
2026.04.02 06:23:24 UTC
Installation of the Radio Altimeter-Transceiver Fan
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| REFERENCE | DESIGNATION |
|---|---|
| No specific | CABLE TIES |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 152 | AFT CARGO COMPARTMENT |
| 152HW |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 34-42-00-750-001-A | Operational Check and Detailed Inspection for Contamination of Radio Altimeter Fan |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 34-42-45-860-050-A
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001)
(2) Make sure that the Aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) is open.
(3) Make sure that the access panel 152HW is removed.
(4) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the Aft cargo door 826.
Subtask 34-42-45-865-051-A (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001)
(2) Make sure that the Aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001) is open.
(3) Make sure that the access panel 152HW is removed.
(4) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the Aft cargo door 826.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3SA1 (FANRA XCVR1) | |||
| 121VU | COM NAV/RAD ALTM/1 | 1SA1 | K11 |
| FOR FIN: 3SA2 (FANRA XCVR2) | |||
| 121VU | COM NAV/RAD ALTM/2 | 1SA2 | K12 |
Subtask 34-42-45-420-050-B
A. Installation of the Radio Altimeter-Transceiver Fan
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Install the blower (7) with the washers (5), bolts (8) and nuts (4) on the cool-air inlet (6).
(a) Make sure that the air flow arrow on the blower (7) points to the radio altimeter transceiver.
(6) Tighten the nuts (4).
(7) Connect the electrical connections (10).
(8) Install the cool-air inlet (6) with the washers (11) and the bolts (12) on the plate (1).
(9) Tighten the bolts (12).
(10) Install the plate (1) with the washers (2) and the screws (3) on the structure.
(11) Tighten the screws (3).
(12) Do a check of the maximum bonding value between the screws (3) and the structure (Ref. AMM TASK 20-28-00-912-802):
(14) Install the CABLE TIES.
Subtask 34-42-45-865-052-A (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Install the blower (7) with the washers (5), bolts (8) and nuts (4) on the cool-air inlet (6).
(a) Make sure that the air flow arrow on the blower (7) points to the radio altimeter transceiver.
(6) Tighten the nuts (4).
(7) Connect the electrical connections (10).
(8) Install the cool-air inlet (6) with the washers (11) and the bolts (12) on the plate (1).
(9) Tighten the bolts (12).
(10) Install the plate (1) with the washers (2) and the screws (3) on the structure.
(11) Tighten the screws (3).
(12) Do a check of the maximum bonding value between the screws (3) and the structure (Ref. AMM TASK 20-28-00-912-802):
- Make sure that the maximum bonding value is not more than ten milliohms.
(14) Install the CABLE TIES.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 34-42-45-750-050-A 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 3SA1 (FANRA XCVR1) | |||
| 121VU | COM NAV/RAD ALTM/1 | 1SA1 | K11 |
| FOR FIN: 3SA2 (FANRA XCVR2) | |||
| 121VU | COM NAV/RAD ALTM/2 | 1SA2 | K12 |
Subtask 34-42-45-410-050-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 152HW.
(3) Remove the access platform(s).
(4) Close the AFT Cargo Door 826 (Ref. AMM TASK 52-30-00-860-002).
Subtask 34-42-45-862-050-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panel 152HW.
(3) Remove the access platform(s).
(4) Close the AFT Cargo Door 826 (Ref. AMM TASK 52-30-00-860-002).