W DOC AIRBUS | AMM A320F

Removal of the Weather Radar Transceiver


TASK 34-41-33-000-802-A
Removal of the Weather Radar Transceiver


ZONE: 121
FIN: 1SQ1 ** ON A/C NOT FOR ALL
FIN: 1SQ2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
811
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 31-32-00-860-010-A
Procedure to Get Access to the SYSTEM REPORT/TEST NAV Page
TASK 31-32-00-860-805-A
Procedure to Get Access to the Radar Trouble Shooting-Data Page
F Weather Radar Transceiver ** ON A/C NOT FOR ALL
F Weather Radar Transceiver ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 34-41-33-810-052-A ** ON A/C NOT FOR ALL
A. Print the troubleshooting data:
   (1) If necessary and applicable, print the troubleshooting data as follows:
     (a) Get access to the SYSTEM/REPORT TEST NAV page (Ref. AMM TASK 31-32-00-860-010).
     (b) Get access to the weather radar transceiver (1) page.
     (c) Get access to the troubleshooting-data page (Ref. AMM TASK 31-32-00-860-805).
     (d) Print the troubleshooting data.
Subtask 34-41-33-865-069-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
Subtask 34-41-33-010-058-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position below access door 811.
   (2) Open access door 811.
4. Procedure
Subtask 34-41-33-020-053-A ** ON A/C NOT FOR ALL
A. Removal of the Weather Radar Transceiver
   (1) Loosen the nuts (3).
   (2) Lower the nuts (3).
   (3) Pull the weather radar transceiver (1) on its rack (4) to disconnect the electrical connectors (5).
   (4) Remove the weather radar transceiver (1) from its rack (4).
   (5) Put the CAP - BLANKING on the disconnected electrical connectors (5).
[Rev.10 from 2021] 2026.04.02 06:23:22 UTC