Reactivation of the OANC
TASK 34-38-00-440-801-A
Reactivation of the OANC
To do a reactivation of the OANC.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-38-00-860-052-A ** ON A/C NOT FOR ALL
Subtask 34-38-00-440-050-A ** ON A/C NOT FOR ALL
Subtask 34-38-00-860-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:19 UTC
Reactivation of the OANC
ZONE: 210
1. Reason for the JobTo do a reactivation of the OANC.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 34-38-00-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 34-38-00-440-050-A ** ON A/C NOT FOR ALL
A. Reactivation of the OANC
(1) On the panel 121VU, remove the tag and SAFETY CLIP - CIRCUIT BREAKER.
(2) Do the trouble shooting of the OANS. Use the Fault Symptom as entry into the TSM.
5. Close-up(1) On the panel 121VU, remove the tag and SAFETY CLIP - CIRCUIT BREAKER.
(2) Do the trouble shooting of the OANS. Use the Fault Symptom as entry into the TSM.
Subtask 34-38-00-860-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
(1) Make sure that the work area is clean and clear of tools and other items.
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)