Operational Check of ISIS DC HOT Bus SUPPLY
TASK 34-22-25-710-001-A
Operational Check of ISIS DC HOT Bus SUPPLY
Refer to the MPD TASK: 342000-03
OPERATIONAL CHECK OF ISIS DC HOT BUS SUPPLY
Test of the correct power supply of ISIS DC HOT BUS in emergency configuration when the batteries are the only power supply source.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 34-22-25-861-052-A ** ON A/C NOT FOR ALL
Subtask 34-22-25-740-052-A ** ON A/C NOT FOR ALL
Subtask 34-22-25-860-065-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:00:02 UTC
Operational Check of ISIS DC HOT Bus SUPPLY
ZONE: 210
1. Reason for the JobRefer to the MPD TASK: 342000-03
OPERATIONAL CHECK OF ISIS DC HOT BUS SUPPLY
Test of the correct power supply of ISIS DC HOT BUS in emergency configuration when the batteries are the only power supply source.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 34-22-25-861-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 34-22-25-860-063-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Aircraft Maintenance Configuration
(1) On the SWITCHING panel 8VU, make sure that the AIR DATA selector switch is at NORM.
Subtask 34-22-25-865-063-A ** ON A/C NOT FOR ALL (1) On the SWITCHING panel 8VU, make sure that the AIR DATA selector switch is at NORM.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-22-25-860-064-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV/STBY/INST | 5FN | F12 |
| 105VU | NAV/STBY/INST/BAT | 23FN | J01 |
D. Aircraft Maintenance Configuration
(1) On panel 35VU, make sure that the ELEC/ BAT1 and ELEC/BAT2 pushbutton switches are released.
4. Procedure(1) On panel 35VU, make sure that the ELEC/ BAT1 and ELEC/BAT2 pushbutton switches are released.
- The OFF legends is on.
Subtask 34-22-25-740-052-A ** ON A/C NOT FOR ALL
A. Operational Test of ISIS DC HOT BUS SUPPLY
5. Close-up| ACTION | RESULT |
|---|---|
| 1.Open circuit breaker 5FN. | On panel 401VU:
|
2.On overhead panel:
|
|
3.On the overhead panel:
| |
| 4.Close circuit breaker 5FN. |
|
Subtask 34-22-25-860-065-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
Subtask 34-22-25-862-051-A ** ON A/C NOT FOR ALL