Removal of the Metric Altimeter
TASK 34-21-25-000-001-A
Removal of the Metric Altimeter
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-21-25-865-050-A ** ON A/C NOT FOR ALL
Subtask 34-21-25-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:13:53 UTC
Removal of the Metric Altimeter
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | CAP - BLANKING |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| F1402369 | 1 | EXTRACTING TOOL |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 34-21-25-865-050-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 34-21-25-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/INSTL LT/MAIN INST/PNL AND/PED | 4LF | Y04 |
B. Remove the thermoformed cover from the center instrument panel.
4. ProcedureSubtask 34-21-25-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Metric Altimeter (15FN)
(1) Loosen the screws (1), do not remove them .
(2) Push the screws (1) to release the metric altimeter (2).
(3) Remove the metric altimeter (2) from its housing with F1402369 EXTRACTING TOOL.
(4) Disconnect the electrical connector (5).
(5) Disconnect the quick-disconnect coupling (6).
(6) Remove the metric altimeter (2).
(7) Put CAP - BLANKING on the disconnected electrical connectors (3) and (5).
(8) Put PLUG - BLANKING on the disconnected pneumatic connectors (4) and (6).
(1) Loosen the screws (1), do not remove them .
(2) Push the screws (1) to release the metric altimeter (2).
(3) Remove the metric altimeter (2) from its housing with F1402369 EXTRACTING TOOL.
(4) Disconnect the electrical connector (5).
(5) Disconnect the quick-disconnect coupling (6).
(6) Remove the metric altimeter (2).
(7) Put CAP - BLANKING on the disconnected electrical connectors (3) and (5).
(8) Put PLUG - BLANKING on the disconnected pneumatic connectors (4) and (6).
Metric Altimeter