Functional Test of the Standby Airspeed Indicator
TASK 34-21-00-720-001-A
Functional Test of the Standby Airspeed Indicator
1. Reason for the Job
To make sure that the standby instruments operate independently.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-21-00-860-065-A ** ON A/C NOT FOR ALL
Subtask 34-21-00-865-061-A ** ON A/C NOT FOR ALL
Subtask 34-21-00-720-050-A ** ON A/C NOT FOR ALL
Subtask 34-21-00-860-051-C ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:13 UTC
Functional Test of the Standby Airspeed Indicator
1. Reason for the Job
To make sure that the standby instruments operate independently.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ALT34100001 | 1 | PITOT AND STATIC TEST SET |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-24-34-600-001-A | Bleeding of the Standby Air Data System |
Subtask 34-21-00-860-065-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Drain the standby air-data system (Ref. AMM TASK 12-24-34-600-001).
Subtask 34-21-00-865-056-A ** ON A/C NOT FOR ALL (1) Drain the standby air-data system (Ref. AMM TASK 12-24-34-600-001).
WARNING:
OPEN CIRCUIT BREAKER 7XE. THIS WILL PREVENT A POSSIBLE DEPLOYMENT OF THE RAT IF THE MAIN AC BUSBARS 1XP AND 2XP BECOME ISOLATED.
B. Open, safety and tag this(these) circuit breaker(s):| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 105VU | ELEC/CSM/G /EV AUTO/SPLY | 7XE | C01 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-21-00-860-050-D ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV/STBY/ALTM | 16FN | F14 |
D. Aircraft Maintenance Configuration
(1) Remove the slip on covers from the standby static probes and the standby pitot probe.
(2) Connect the ALT34100001 PITOT AND STATIC TEST SET to the left or right standby static-probe with the ADAPTER STATIC PROBE.
(3) Connect the ALT34100001 PITOT AND STATIC TEST SET to the standby pitot probe with the ADAPTER PITOT PROBE.
(5) Precautions
4. Procedure(1) Remove the slip on covers from the standby static probes and the standby pitot probe.
(2) Connect the ALT34100001 PITOT AND STATIC TEST SET to the left or right standby static-probe with the ADAPTER STATIC PROBE.
(3) Connect the ALT34100001 PITOT AND STATIC TEST SET to the standby pitot probe with the ADAPTER PITOT PROBE.
NOTE: The ADAPTER PITOT PROBE is on the drain hole. Thus it is not necessary to seal the drain hole of the pitot probe.
(4) Seal the opposite standby static-probe with the piece of plastic and with the ADAPTER STATIC COVER from the ADAPTER STATIC PROBE.(5) Precautions
CAUTION:
TO PREVENT DAMAGE TO INSTRUMENTS, OBEY THESE PRECAUTIONS WHEN YOU DO THE TEST:
- THE PRESSURES SET MUST NOT BE MORE THAN 1050 hPa (31 in Hg) OR LESS THAN 115 hPa (3.39 in Hg)
- CHANGES IN STATIC AND TOTAL PRESSURES MUST NOT BE MORE THAN 6000 FEET/MINUTE
- DO NOT SUDDENLY OPEN LINES TO AMBIENT AIR WHILE THE PRESSURE GENERATOR IS CONNECTED.
CAUTION:
THE TOTAL PRESSURE IN THE PITOT SYSTEM MUST NEVER BE LESS THAN THE STATIC PRESSURE. THE DIFFERENCE BETWEEN THE PITOT AND THE STATIC PRESSURE CIRCUITS MUST NEVER BE MORE THAN 368 hPa (10.86 in Hg).
(6) Start the ground pressure generator. Subtask 34-21-00-720-050-A ** ON A/C NOT FOR ALL
A. Test of the Standby Airspeed Indicator
5. Close-up| ACTION | RESULT |
|---|---|
On the ground pressure generator :
| On the standby airspeed indicator:
|
|
|
|
|
Subtask 34-21-00-860-051-C ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) On the ground pressure generator, slowly decrease the pressure until you get atmospheric pressure.
(2) Stop the ALT34100001 PITOT AND STATIC TEST SET.
(3) Disconnect the ALT34100001 PITOT AND STATIC TEST SET.
(4) Remove the adaptors from the standby static probes and the standby pitot probe.
(5) Remove the cover from the opposite standby static probe.
(6) Remove the piece of plastic from the opposite standby static probe.
(7) Install the slip on covers on the standby static probes and the standby pitot probe.
(8) Do a reset of each ELAC:
Subtask 34-21-00-865-057-A ** ON A/C NOT FOR ALL (1) On the ground pressure generator, slowly decrease the pressure until you get atmospheric pressure.
(2) Stop the ALT34100001 PITOT AND STATIC TEST SET.
(3) Disconnect the ALT34100001 PITOT AND STATIC TEST SET.
(4) Remove the adaptors from the standby static probes and the standby pitot probe.
(5) Remove the cover from the opposite standby static probe.
(6) Remove the piece of plastic from the opposite standby static probe.
(7) Install the slip on covers on the standby static probes and the standby pitot probe.
(8) Do a reset of each ELAC:
- On the panel 49VU, open then close the ELAC1 C/B
- On the panel 121VU, open then close the ELAC2 C/B.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 105VU | ELEC/CSM/G /EV AUTO/SPLY | 7XE | C01 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
| 122VU | ANTI ICE/PROBES/3/PITOT | 3DA3 | Z16 |
| 122VU | ANTI ICE/PROBES/3/AOA | 4DA3 | Z15 |
| 122VU | ANTI ICE/PROBES/3/STATIC | 5DA3 | Z14 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |