ISIS Reset
TASK 34-20-00-710-802-A
ISIS Reset
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
3. Job Set-up
Subtask 34-20-00-865-052-A ** ON A/C NOT FOR ALL
Subtask 34-20-00-710-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:12 UTC
ISIS Reset
ZONE: 210
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
Subtask 34-20-00-865-052-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV/STBY/INST | 5FN | F12 |
Subtask 34-20-00-710-052-A ** ON A/C NOT FOR ALL
A. Reset of the ISIS Indicator.
(1) On the panel 49VU, open the NAV/STBY/INST circuit breaker for more than 5 seconds then close it.
(2) After some seconds, on the ISIS Indicator, the INIT page comes into view.
(1) On the panel 49VU, open the NAV/STBY/INST circuit breaker for more than 5 seconds then close it.
(2) After some seconds, on the ISIS Indicator, the INIT page comes into view.