Removal of the ADIRU
TASK 34-12-34-000-001-A
Removal of the ADIRU
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-12-34-010-050-A
Subtask 34-12-34-020-050-A
[Rev.10 from 2021]
2026.04.02 06:23:06 UTC
Removal of the ADIRU
CAUTION:
DO NOT REMOVE THE RACK OF THIS UNIT.
PRECISION ADJUSTMENT IS NECESSARY TO INSTALL THE RACK CORRECTLY. THE MANUFACTURER DOES THIS ADJUSTMENT BEFORE DELIVERY OF THE AIRCRAFT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| FOR [1FP1] (ADIRU-1) | ||
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 127 | REAR AVIONIC COMPARTMENT |
| 128 | REAR AVIONIC COMPARTMENT |
| 824 | |
| FOR [1FP1] (ADIRU-1) | |
| 822 | |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 34-12-34-010-050-A
A. Get Access
(1) FOR [1FP1] (ADIRU-1)
(a) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 822.
(b) Open the access door 822.
(c) On the battery power center 105VU:
(3) Open the access door 824.
Subtask 34-12-34-865-050-A (1) FOR [1FP1] (ADIRU-1)
(a) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 822.
(b) Open the access door 822.
(c) On the battery power center 105VU:
- loosen the two screws and remove the protective cover.
(3) Open the access door 824.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| FOR FIN: 1FP1 (ADIRU1) | |||
| 49VU | NAV PROBES/ADIRU 1/AND AOA 1/26VAC | 5FP1 | F07 |
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 105VU | ADIRS/ADIRU1/28VDC | 6FP1 | C02 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1FP2 (ADIRU2) | |||
| 121VU | ADIRS/ADIRU/2PWR/SHED | 10FP | N10 |
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/2/26VAC AND AOA | 5FP2 | N08 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 121VU | ADIRS/ADIRU/2/28VDC | 6FP2 | N04 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | ADIRS/2PWR/SHED &/AOA2 MON | 10FP | N10 |
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1FP3 (ADIRU3) | |||
| 49VU | NAV PROBES/ADIRU3/PWR/SWTG | 8FP | F09 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV PROBES/ADIRU3/PWR/SWTG | 8FP | F08 |
| ** ON A/C ALL | |||
| 121VU | ADIRS/ADIRU/3PWR/SWTG | 9FP | N09 |
| 121VU | ADIRS/ADIRU/3/26VAC AND AOA | 5FP3 | N07 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 121VU | ADIRS/ADIRU/3/28VDC | 6FP3 | N03 |
Subtask 34-12-34-020-050-A
A. Removal of the ADIRU (1FP1, 1FP2, 1FP3)
(2) Lower the nuts (4).
(3) Pull the ADIRU (6) on its rack (3) to disconnected the electrical connectors (1).
(4) Remove the ADIRU (6) from its rack (3).
(5) Put blanking caps on the disconnected electrical connectors (1).
NOTE: The procedure is the same for the three ADIRUs 1FP1, 1FP2 and 1FP3.
(1) Loosen the nuts (4). (2) Lower the nuts (4).
(3) Pull the ADIRU (6) on its rack (3) to disconnected the electrical connectors (1).
(4) Remove the ADIRU (6) from its rack (3).
(5) Put blanking caps on the disconnected electrical connectors (1).
Air Data/Inertial Reference Unit (ADIRU)