Installation of the ADIRS CDU
TASK 34-12-12-400-001-A
Installation of the ADIRS CDU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-12-12-010-051-A ** ON A/C NOT FOR ALL
Subtask 34-12-12-420-050-A ** ON A/C NOT FOR ALL
Subtask 34-12-12-860-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:05 UTC
Installation of the ADIRS CDU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 34-10-00-710-001-A | Check of the ADIRS CDU Brightness and Display |
Subtask 34-12-12-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position at the access door 822.
(2) Make sure that the access door 822 is open.
(3) Make sure that the protective cover is removed from the battery power center 105VU.
Subtask 34-12-12-865-051-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position at the access door 822.
(2) Make sure that the access door 822 is open.
(3) Make sure that the protective cover is removed from the battery power center 105VU.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 105VU | ADIRS/ADIRU1/28VDC | 6FP1 | C02 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 121VU | ADIRS/ADIRU/2/28VDC | 6FP2 | N04 |
| 121VU | ADIRS/ADIRU/3/28VDC | 6FP3 | N03 |
| 122VU | LIGHTING/TST/BOARD/SPLY | 30LP | X06 |
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 2 | 27LP | X05 |
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 1 | 26LP | X04 |
| 122VU | LIGHTING/INSTL LT/OVHD/PNL | 3LF | Y03 |
Subtask 34-12-12-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the ADIRS CDU (2FP)
(1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking caps from the electrical connectors (2) and (3).
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Connect the electrical connectors (2) to the related receptacles (3).
(6) Install the CDU (4) in its housing (1).
(7) Tighten the four quarter turn fasteners (5).
Subtask 34-12-12-865-052-A ** ON A/C NOT FOR ALL (1) Clean the component interfaces and the adjacent area.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Remove the blanking caps from the electrical connectors (2) and (3).
(4) Make sure that all the electrical connections are clean and in the correct condition.
(5) Connect the electrical connectors (2) to the related receptacles (3).
(6) Install the CDU (4) in its housing (1).
(7) Tighten the four quarter turn fasteners (5).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 34-12-12-710-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 105VU | ADIRS/ADIRU1/28VDC | 6FP1 | C02 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 121VU | ADIRS/ADIRU/2/28VDC | 6FP2 | N04 |
| 121VU | ADIRS/ADIRU/3/28VDC | 6FP3 | N03 |
| 122VU | LIGHTING/TST/BOARD/SPLY | 30LP | X06 |
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 2 | 27LP | X05 |
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 1 | 26LP | X04 |
| 122VU | LIGHTING/INSTL LT/OVHD/PNL | 3LF | Y03 |
Subtask 34-12-12-860-050-A ** ON A/C NOT FOR ALL
A. Make sure that the work area is clean and clear of tools and other items.
Subtask 34-12-12-410-050-A ** ON A/C NOT FOR ALL B. Close Access
(1) Install the protective cover on the battery power center 105VU.
(2) Tighten the two screws.
(3) Close the access door 822
(4) Remove the access platform(s).
(1) Install the protective cover on the battery power center 105VU.
(2) Tighten the two screws.
(3) Close the access door 822
(4) Remove the access platform(s).
ADIRS - Control and Display Unit (CDU)