Removal of the ADIRS CDU
TASK 34-12-12-000-001-A
Removal of the ADIRS CDU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 34-12-12-010-050-A ** ON A/C NOT FOR ALL
Subtask 34-12-12-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:23:05 UTC
Removal of the ADIRS CDU
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 211 | COCKPIT |
| 822 |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 34-12-12-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 822.
(2) Open the access door 822.
(3) On the battery power center 105 VU:
Subtask 34-12-12-865-050-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 1M(3 FT) in position at the access door 822.
(2) Open the access door 822.
(3) On the battery power center 105 VU:
- loosen the two screws and remove the protective cover.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 105VU | ADIRS/ADIRU1/28VDC | 6FP1 | C02 |
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 121VU | ADIRS/ADIRU/2/28VDC | 6FP2 | N04 |
| 121VU | ADIRS/ADIRU/3/28VDC | 6FP3 | N03 |
| 122VU | LIGHTING/TST/BOARD/SPLY | 30LP | X06 |
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 2 | 27LP | X05 |
| 122VU | LIGHTING/ANN LT SPLY/XFMR/BUS 1 | 26LP | X04 |
| 122VU | LIGHTING/INSTL LT/OVHD/PNL | 3LF | Y03 |
Subtask 34-12-12-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the ADIRS CDU (2FP)
(1) Hold the CDU (4) and loosen the four quarter turn fasteners (5).
(2) Disengage the CDU (4) from its housing (1).
(3) Disconnect the three electrical connectors (2).
(4) Remove the CDU (4).
(5) Put CAP - BLANKING on the disconnected electrical connectors (2) and (3).
(1) Hold the CDU (4) and loosen the four quarter turn fasteners (5).
(2) Disengage the CDU (4) from its housing (1).
(3) Disconnect the three electrical connectors (2).
(4) Remove the CDU (4).
(5) Put CAP - BLANKING on the disconnected electrical connectors (2) and (3).
ADIRS - Control and Display Unit (CDU)