W DOC AIRBUS | AMM A320F

Test of the TAT Sensor without the CFDS


TASK 34-11-18-710-001-A
Test of the TAT Sensor without the CFDS


ZONE: 121
ZONE: 122
ZONE: 210
FIN: 11FP1
FIN: 11FP2
1. Reason for the Job
Do this test after the removal/installation of the TAT Sensor (11FP1,11FP2) when the CFDS is unserviceable.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
121
AVIONICS COMPARTMENT
122
AVIONICS COMPARTMENT
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 34-10-00-860-005-A
ADIRS Stop Procedure
FOR [11FP2] (SENSOR-TAT, 2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 34-10-00-860-002-A
ADIRS Start Procedure
3. Job Set-up
Subtask 34-11-18-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure
     (a) FOR [11FP1] (SENSOR-TAT, 1)
Lower ECAM DU and CAPT ND only
     (b) FOR [11FP2] (SENSOR-TAT, 2)
Lower ECAM DU only
(Ref. AMM TASK 31-60-00-860-001).
   (3) Do the ADIRS start procedure
     (a) FOR [11FP1] (SENSOR-TAT, 1)
ADIRU 1 and 3 only
     (b) FOR [11FP2] (SENSOR-TAT, 2)
ADIRU 2 only
(Ref. AMM TASK 34-10-00-860-002).
Subtask 34-11-18-860-051-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure
     (a) FOR [11FP1] (SENSOR-TAT, 1)
Lower ECAM DU and CAPT ND only
     (b) FOR [11FP2] (SENSOR-TAT, 2)
F/O ND only
(Ref. AMM TASK 31-60-00-860-001).
   (3) Do the ADIRS start procedure
     (a) FOR [11FP1] (SENSOR-TAT, 1)
ADIRU 1 and 3 only
     (b) FOR [11FP2] (SENSOR-TAT, 2)
ADIRU 2 only
(Ref. AMM TASK 34-10-00-860-002).
Subtask 34-11-18-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 11FP1 (SENSORTAT, 1)
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
121VUADIRS/ADIRU/3/115VAC4FP3N05
122VUANTI ICE/PROBES/1/TAT1DA1Z12
FOR FIN: 11FP2 (SENSORTAT, 2)
121VUADIRS/ADIRU/2/115VAC4FP2N06
122VUANTI ICE/PROBES/2/TAT1DA2Y15
4. Procedure
Subtask 34-11-18-710-051-A ** ON A/C NOT FOR ALL
A. Test of the TAT Sensor
   (1) Operational test of the TAT sensor 11FP1:
ACTION
RESULT
On the SWITCHING panel 8VU:

  • set the ECAM/ND XFR selector switch to CAPT.
  • the display of the lower ECAM DU moves to the CAPT ND.
  • make sure that the SAT and TAT indications are shown at the bottom of the CAPT ND, on the left side.
  • set the AIR DATA selector switch to CAPT/3.
  • make sure that the SAT and TAT indications stay in view on the CAPT ND.
  • set the ECAM/ND XFR and AIR DATA selector switches to NORM.

   (2) Operational test of the TAT sensor 11FP2:
  • Make sure that the SAT and TAT indications are shown at the bottom section of the lower ECAM DU, on the left side.
Subtask 34-11-18-710-051-B ** ON A/C NOT FOR ALL
A. Test of the TAT Sensor
   (1) Operational test of the TAT sensor 11FP1:
ACTION
RESULT
On the SWITCHING panel 8VU:
  • make sure that the selector switches are at the NORM position.
On the lower ECAM DU:
  • the TAT indication is shown at the bottom section of the lower ECAM DU, on the left side.
  • set the ECAM/ND XFR selector switch to CAPT.
  • the display of the lower ECAM DU moves to the CAPT ND.
  • make sure that the SAT and TAT indications are shown at the bottom of the CAPT ND, on the left side.
  • set the ECAM/ND XFR selector switch to NORM.

  • set the AIR DATA selector switch to CAPT/3.
  • make sure that the SAT and TAT indications are shown at the bottom section of the lower ECAM DU, on the left side (from ADIRU 3).
  • set the ECAM/ND XFR selector switch to F/O.
  • set the AIR DATA selector switches to F/O/3.
  • make sure that the SAT and TAT indications are shown at the bottom of the F/O ND, on the left side (from ADIRU 3).
  • set the ECAM/ND XFR selector switch to NORM.
  • set the AIR DATA selector switches to NORM..

   (2) Operational test of the TAT sensor 11FP2:
     (a) set the ECAM/ND XFR selector switch to F/O.
  • make sure that the SAT and TAT indications are shown at the bottom of the F/O ND, on the left side.
     (b) set the ECAM/ND XFR selector switch to NORM.
5. Close-up
Subtask 34-11-18-860-050-A
A. Put the aircraft back to its initial configuration.
   (1) Do the ADIRS Stop Procedure (Ref. AMM TASK 34-10-00-860-005).
   (2) On the center pedestal, on the ECAM control panel, set the LOWER DISPLAY potentiometer to OFF.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
   (4) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.01 00:58:32 UTC