Inspection/Check of the TAT Sensor
TASK 34-11-18-200-002-A
Inspection/Check of the TAT Sensor
The purpose of this Task is to do a Visual Inspection of the TAT sensor
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 34-11-18-865-054-A
Subtask 34-11-18-220-050-A
Subtask 34-11-18-865-055-A
[Rev.10 from 2021]
2026.04.01 00:58:34 UTC
Inspection/Check of the TAT Sensor
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobThe purpose of this Task is to do a Visual Inspection of the TAT sensor
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WATER SOURCE - GROUND |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08ABC1) | Aqueous Cleaner-Aircraft Exterior Pressure Spraying - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121 | AVIONICS COMPARTMENT |
| 122 | AVIONICS COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 34-11-18-000-001-A | Removal of the TAT Sensor |
| TASK 34-11-18-400-001-A | Installation of the TAT Sensor |
| TASK 34-11-18-000-001-A | Removal of the TAT Sensor (for corrective action) |
| TASK 34-11-18-400-001-A | Installation of the TAT Sensor (for corrective action) |
Subtask 34-11-18-865-054-A
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 34-11-18-860-056-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| FOR FIN: 11FP1 (SENSORTAT, 1) | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| FOR FIN: 11FP2 (SENSORTAT, 2) | |||
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
B. Get Access
(1) Put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position in zone 120.
(2) Remove the TAT sensor slip-on cover.
4. Procedure(1) Put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position in zone 120.
(2) Remove the TAT sensor slip-on cover.
Subtask 34-11-18-220-050-A
A. Inspection/Check of the Total Air Temperature (TAT) Sensors (11FP1, 11FP2)
(1) Do a general visual inspection of the TAT sensors:
(a) Color
With time, the color of the sensor becomes brown and/or black.
This coloration has no effect on the operation of the sensor.
(b) Internal obstruction
1 Make sure that the TAT sensor is not clogged.
2 Use a moist clean Textile-Lint free Cotton - (Material No.14SBA1) and remove the contamination. Make the Textile-Lint free Cotton - (Material No.14SBA1) moist with an applicable Non Aqueous Cleaner-General - - (Material No.08BAA9) .
3 Flush the unit fully with clean WATER SOURCE - GROUND.
(d) If there are signs of lightning strike (burn marks, spots, etc.) on one of the TAT sensors, replace it (Ref. AMM TASK 34-11-18-000-001) and (Ref. AMM TASK 34-11-18-400-001).
(e) If the TAT sensor is not in the correct condition (oxidation, impact marks, cracks, ...) replace it (Ref. AMM TASK 34-11-18-000-001) and (Ref. AMM TASK 34-11-18-400-001).
5. Close-up(1) Do a general visual inspection of the TAT sensors:
(a) Color
With time, the color of the sensor becomes brown and/or black.
This coloration has no effect on the operation of the sensor.
(b) Internal obstruction
1 Make sure that the TAT sensor is not clogged.
CAUTION:
DO NOT USE SHARP AND/OR METAL TOOLS OR OBJECTS TO CLEAN THE TAT SENSOR. SUCH TOOLS OR OBJECTS CAN CAUSE DAMAGE TO THE TAT SENSOR.
a If the TAT sensor is clogged, remove it (Ref. AMM TASK 34-11-18-000-001). - Send the TAT sensor to the workshop.
- Install the TAT sensor (Ref. AMM TASK 34-11-18-400-001).
CAUTION:
DO NOT USE ROUGH ABRASIVE CLEANERS. IF YOU DO, YOU CAN CAUSE DAMAGE TO THE PLATING.
1 Clean the surfaces of the TAT sensor with a solution of WATER SOURCE - GROUND and Aqueous Cleaner-Aircraft Exterior Pressure Spraying - (Material No.08ABC1) . 2 Use a moist clean Textile-Lint free Cotton - (Material No.14SBA1) and remove the contamination. Make the Textile-Lint free Cotton - (Material No.14SBA1) moist with an applicable Non Aqueous Cleaner-General - - (Material No.08BAA9) .
3 Flush the unit fully with clean WATER SOURCE - GROUND.
(d) If there are signs of lightning strike (burn marks, spots, etc.) on one of the TAT sensors, replace it (Ref. AMM TASK 34-11-18-000-001) and (Ref. AMM TASK 34-11-18-400-001).
(e) If the TAT sensor is not in the correct condition (oxidation, impact marks, cracks, ...) replace it (Ref. AMM TASK 34-11-18-000-001) and (Ref. AMM TASK 34-11-18-400-001).
Subtask 34-11-18-865-055-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 34-11-18-860-057-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RADAR/1 | 5SQ1 | K13 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/RADAR/2 | 5SQ2 | K14 |
| ** ON A/C ALL | |||
| FOR FIN: 11FP1 (SENSORTAT, 1) | |||
| 49VU | ANTI ICE/PROBES/AOA/1 | 4DA1 | D04 |
| 49VU | ANTI ICE/PROBES/PHC/1 | 2DA1 | D03 |
| 49VU | ANTI ICE/PROBES/PITOT/1 | 3DA1 | D02 |
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 121VU | ADIRS/ADIRU/3/115VAC | 4FP3 | N05 |
| 122VU | ANTI ICE/PROBES/1/STATIC | 5DA1 | Z13 |
| 122VU | ANTI ICE/PROBES/1/TAT | 1DA1 | Z12 |
| FOR FIN: 11FP2 (SENSORTAT, 2) | |||
| 121VU | ADIRS/ADIRU/2/115VAC | 4FP2 | N06 |
| 122VU | ANTI ICE/PROBES/2/TAT | 1DA2 | Y15 |
| 122VU | ANTI ICE/PROBES/2/PITOT | 3DA2 | Y14 |
| 122VU | ANTI ICE/PROBES/2/AOA | 4DA2 | Y13 |
| 122VU | ANTI ICE/PROBES/PHC/2 | 2DA2 | Y12 |
| 122VU | ANTI ICE/PROBES/2/STATIC | 5DA2 | Y11 |
B. Put the aircraft back to its initial configuration.
(1) Install the TAT sensor slip-on cover.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(1) Install the TAT sensor slip-on cover.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).