Installation of the Air Data Module (ADM)


TASK 34-11-17-400-001-A
Installation of the Air Data Module (ADM)


ZONE: 110
ZONE: 120
FIN: 19FP1
FIN: 19FP2
FIN: 19FP3
FIN: 19FP4
FIN: 19FP5
FIN: 19FP6
FIN: 19FP7
FIN: 19FP8
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
FOR [19FP4] (ADM-R STATIC PRESSURE)
FOR [19FP6] (ADM-R STATIC PRESSURE)
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
110
RADOME (NOSE CONE TO FR 1)
120
AVIONICS COMPARTMENT
824
FOR [19FP1] (ADM-L TOTAL PRESSURE)
FOR [19FP3] (ADM-STBY TOTAL PRESSURE)
812
FOR [19FP2] (ADM-R TOTAL PRESSURE)
822
FOR [19FP4] (ADM-R STATIC PRESSURE)
FOR [19FP6] (ADM-R STATIC PRESSURE)
824
FOR [19FP4] (ADM-R STATIC PRESSURE)
FOR [19FP5] (ADM-L STATIC PRESSURE)
FOR [19FP6] (ADM-R STATIC PRESSURE)
FOR [19FP7] (ADM-L STATIC PRESSURE)
824
FOR [19FP8] (ADM-STBY STATIC PRESSURE)
811
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
FOR [19FP1] (ADM-L TOTAL PRESSURE)
FOR [19FP2] (ADM-R TOTAL PRESSURE)
FOR [19FP3] (ADM-STBY TOTAL PRESSURE)
10
SPACER
AIPC 34-11-01-05-110
10
SPACER
AIPC 34-11-81-05-040
FOR [19FP4] (ADM-R STATIC PRESSURE)
FOR [19FP5] (ADM-L STATIC PRESSURE)
FOR [19FP6] (ADM-R STATIC PRESSURE)
FOR [19FP7] (ADM-L STATIC PRESSURE)
10
SPACER
AIPC 34-11-01-04-060
10
SPACER
AIPC 34-11-81-04-040
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 34-11-17-710-001-A
Test of the Air Data Module without the CFDS
TASK 34-13-00-740-003-A
SYSTEM TEST of the ADR
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
F Air Data Module ** ON A/C NOT FOR ALL
F Air Data Module ** ON A/C NOT FOR ALL
FOR [19FP4] (ADM-R STATIC PRESSURE)
FOR [19FP5] (ADM-L STATIC PRESSURE)
FOR [19FP6] (ADM-R STATIC PRESSURE)
FOR [19FP7] (ADM-L STATIC PRESSURE)
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
3. Job Set-up
Subtask 34-11-17-860-050-A
A. Get Access
   (1) Make sure that the applicable ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position:
     (a) In zone 123 for left total pressure ADM 19FP1 and standby total pressure ADM 19FP3.
     (b) In zone 122 for right total pressure ADM 19FP2.
     (c) In zone 128 for right static pressure ADMs 19FP4 and 19FP6 and left static pressure ADMs 19FP5 and 19FP7.
     (d) In zone 110 for standby static pressure ADM 19FP8.
     (e) At access door 822.
   (2) Make sure that the applicable access door is open (Ref. AMM TASK 52-41-00-010-002):
     (a) FOR [19FP1] (ADM-L TOTAL PRESSURE), [19FP3] (ADM-STBY TOTAL PRESSURE)
812
     (b) FOR [19FP2] (ADM-R TOTAL PRESSURE)
822
     (c) FOR [19FP4] (ADM-R STATIC PRESSURE), [19FP5] (ADM-L STATIC PRESSURE), [19FP6] (ADM-R STATIC PRESSURE), [19FP7] (ADM-L STATIC PRESSURE)
824
     (d) FOR [19FP8] (ADM-STBY STATIC PRESSURE)
811
   (3) Make sure that door 822 is open.
   (4) Make sure that the protective cover is removed from battery power center 105VU.
   (5) Clean the component interfaces and the adjacent area.
   (6) Do an inspection of the component interfaces and the adjacent area.
Subtask 34-11-17-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 19FP5 (ADML STATIC PRESSURE) FOR FIN: 19FP4 (ADMR STATIC PRESSURE) FOR FIN: 19FP1 (ADML TOTAL PRESSURE)
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
105VUADIRS/ADIRU1/28VDC6FP1C02
FOR FIN: 19FP7 (ADML STATIC PRESSURE) FOR FIN: 19FP6 (ADMR STATIC PRESSURE) FOR FIN: 19FP2 (ADMR TOTAL PRESSURE)
121VUADIRS/ADIRU/2/115VAC4FP2N06
121VUADIRS/ADIRU/2/28VDC6FP2N04
FOR FIN: 19FP8 (ADMSTBY STATIC PRESSURE) FOR FIN: 19FP3 (ADMSTBY TOTAL PRESSURE)
121VUADIRS/ADIRU/3/115VAC4FP3N05
121VUADIRS/ADIRU/3/28VDC6FP3N03
4. Procedure
Subtask 34-11-17-420-050-B ** ON A/C NOT FOR ALL
A. Installation of the Air Data Module (ADM)
NOTE: ADM 19FP8 has no foam insulation.
   (1) For the installation of ADM 19FP4 or 19FP6:
  • Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to open access door 824.
  • Make sure that access door 824 is closed.
   (2) Put the ADM (3) with its foam insulation (2) in position on the support (1) and hold it in position.
   (3) Attach the ADM (3) with the four screws (5) and the four washers (4).
   (4) Remove the CAP - BLANKING from the disconnected electrical connectors (9) and (6).
   (5) Make sure that all the electrical connections are clean and in the correct condition.
   (6) Connect the electrical connector (9).
   (7) Remove the PLUG - BLANKING from the disconnected quick-disconnect couplings (8) and (7).
   (8) Make sure that the quick-disconnect couplings (8) and (7) are in the correct condition.
   (9) Connect the quick-disconnect coupling (8).
F Quick-Disconnect Coupling ** ON A/C NOT FOR ALL
   (10) Make sure that you can see the blue ring on the quick-disconnect coupling (8).
   (11) Pull the quick-disconnect coupling (8) to make sure that it is correctly attached.
   (12) Make sure that the quick-disconnect coupling (8) is correctly engaged (the pin on the quick-disconnect male part is fully engaged into the groove in the quick-disconnect female part).
   (13) Refer to the table that follows to know if you must do two checks of the quick-disconnect coupling (8) and/or the leak test:
Condition
Two Checks of the Quick-Disconnect Couplings
Leak Test
One ADM system
No
No
Two or more ADM systems
Yes
No
     (a) If you must do two check of the quick-disconnect coupling (8):
  • Tell a second qualified mechanic to do a visual inspection of the quick-disconnect coupling (8) (the signature of the two mechanics is mandatory).
  • Make sure that the quick-disconnect coupling (8) is correctly engaged (the pin located on the quick-disconnect male part must be fully engaged into the groove in the quick-disconnect female part).
Subtask 34-11-17-420-050-D ** ON A/C NOT FOR ALL
A. Installation of the Air Data Module (ADM)
NOTE: ADM 19FP8 has no foam insulation and spacer.
   (1) FOR [19FP4] (ADM-R STATIC PRESSURE), [19FP6] (ADM-R STATIC PRESSURE)
     (a) Make sure that the WARNING NOTICE(S) is (are) in position to tell persons not to open access door 824.
     (b) Make sure that access door 824 is closed.
   (2) FOR [19FP1] (ADM-L TOTAL PRESSURE), [19FP2] (ADM-R TOTAL PRESSURE), [19FP3] (ADM-STBY TOTAL PRESSURE)
     (a) If you install the same spacers, install the four spacers (10) on the foam insulation (2).
     (b) If you install the new spacers, install the four new AIPC 34-11-01-05-110 SPACER (10) or AIPC 34-11-81-05-040 SPACER (10) on the foam insulation (2).
   (3) FOR [
19FP4] (ADM-R STATIC PRESSURE), [19FP5] (ADM-L STATIC PRESSURE), [19FP6] (ADM-R STATIC PRESSURE), [19FP7] (ADM-L STATIC PRESSURE)
     (a) If you install the same spacers, install the four spacers (10) on the foam insulation (2).
     (b) If you install the new spacers, install the four new AIPC 34-11-01-04-060 SPACER (10) or AIPC 34-11-81-04-040 SPACER (10) on the foam insulation (2).
   (4) Put the ADM (3) and the foam insulation (2) in position on the support (1) and hold them.
   (5) Install the ADM (3) on the support (1) with the four screws (5) and the four washers (4).
   (6) Remove the CAP - BLANKING from the disconnected electrical connectors (9) and (6).
   (7) Make sure that all the electrical connections are clean and in the correct condition.
   (8) Connect the electrical connector (9).
   (9) Remove the PLUG - BLANKING from the disconnected quick-disconnect couplings (8) and (7).
   (10) Make sure that the quick-disconnect couplings (8) and (7) are in the correct condition.
   (11)
F Quick-Disconnect Coupling ** ON A/C NOT FOR ALL
   (12) Make sure that you can see the blue ring on the quick-disconnect coupling (8).
   (13) Pull the quick-disconnect coupling (8) to make sure that it is correctly attached.
   (14)    (15) Refer to the table that follows to know if you must do the two checks of the quick-disconnect coupling (8) and/or the leak test:
Condition
Two Checks of the Quick-Disconnect Couplings
Leak Test
One ADM system
No
No
Two or more ADM systems
Yes
No
     (a) If you must do the two checks of the quick-disconnect coupling (8):
       1 Tell a second approved mechanic to do a visual inspection of the quick-disconnect coupling (8) (the signatures of the two mechanics are mandatory).
       2
Subtask 34-11-17-710-050-B
B. Do the SYSTEM TEST of the ADR with the CFDS
(Ref. AMM TASK 34-13-00-740-003).
NOTE: As an alternative procedure, you can do this operational test without the CFDS (Ref. AMM TASK 34-11-17-710-001).
5. Close-up
Subtask 34-11-17-410-050-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the applicable access door (Ref. AMM TASK 52-41-00-410-002):
     (a) FOR [19FP1] (ADM-L TOTAL PRESSURE), [19FP3] (ADM-STBY TOTAL PRESSURE)
812
     (b) FOR [19FP2] (ADM-R TOTAL PRESSURE)
822
     (c) FOR [19FP4] (ADM-R STATIC PRESSURE), [19FP5] (ADM-L STATIC PRESSURE), [19FP6] (ADM-R STATIC PRESSURE), [19FP7] (ADM-L STATIC PRESSURE)
824 (Ref. AMM TASK 52-41-00-410-002)
     (d) FOR [19FP8] (ADM-STBY STATIC PRESSURE)
811
   (3) Remove the WARNING NOTICE(S).
   (4) Install the protective cover on battery power center 105VU.
   (5) Tighten the two screws.
   (6) Close access door 822.
   (7) Remove the access platform(s).