Removal of the Air Data Module


TASK 34-11-17-000-001-A
Removal of the Air Data Module


ZONE: 110
ZONE: 120
FIN: 19FP1
FIN: 19FP2
FIN: 19FP3
FIN: 19FP4
FIN: 19FP5
FIN: 19FP6
FIN: 19FP7
FIN: 19FP8
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
CAP - BLANKING
No specific
AR
PLUG - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
110
RADOME (NOSE CONE TO FR 1)
120
AVIONICS COMPARTMENT
822, 824
FOR [19FP1] (ADM-L TOTAL PRESSURE)
FOR [19FP3] (ADM-STBY TOTAL PRESSURE)
812
FOR [19FP2] (ADM-R TOTAL PRESSURE)
822
FOR [19FP4] (ADM-R STATIC PRESSURE)
FOR [19FP5] (ADM-L STATIC PRESSURE)
FOR [19FP6] (ADM-R STATIC PRESSURE)
FOR [19FP7] (ADM-L STATIC PRESSURE)
824
FOR [19FP8] (ADM-STBY STATIC PRESSURE)
811
 C. Referenced Information
REFERENCE
DESIGNATION
F Air Data Module ** ON A/C NOT FOR ALL
F Air Data Module ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 34-11-17-010-050-A
A. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position :
     (a) In zone 123 for left total pressure ADM 19FP1 and standby total pressure ADM 19FP3.
     (b) In zone 122 for right total pressure ADM 19FP2.
     (c) In zone 128 for right static pressure ADMs 19FP4 and 19FP6 and left static pressure ADMs 19FP5 and 19FP7.
     (d) In zone 110 for standby static pressure ADM 19FP8.
     (e) At access door 822.
   (2) Open the applicable access door:
     (a) FOR [19FP1] (ADM-L TOTAL PRESSURE), [19FP3] (ADM-STBY TOTAL PRESSURE)
812
     (b) FOR [19FP2] (ADM-R TOTAL PRESSURE)
822
     (c) FOR [19FP4] (ADM-R STATIC PRESSURE), [19FP5] (ADM-L STATIC PRESSURE), [19FP6] (ADM-R STATIC PRESSURE), [19FP7] (ADM-L STATIC PRESSURE)
824
     (d) FOR [19FP8] (ADM-STBY STATIC PRESSURE)
811
   (3) Open access door 822.
   (4) On battery power center 105VU:
  • Loosen the two screws and remove the protective cover.
Subtask 34-11-17-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 19FP5 (ADML STATIC PRESSURE) FOR FIN: 19FP4 (ADMR STATIC PRESSURE) FOR FIN: 19FP1 (ADML TOTAL PRESSURE)
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
105VUADIRS/ADIRU1/28VDC6FP1C02
FOR FIN: 19FP7 (ADML STATIC PRESSURE) FOR FIN: 19FP6 (ADMR STATIC PRESSURE) FOR FIN: 19FP2 (ADMR TOTAL PRESSURE)
121VUADIRS/ADIRU/2/115VAC4FP2N06
121VUADIRS/ADIRU/2/28VDC6FP2N04
FOR FIN: 19FP8 (ADMSTBY STATIC PRESSURE) FOR FIN: 19FP3 (ADMSTBY TOTAL PRESSURE)
121VUADIRS/ADIRU/3/115VAC4FP3N05
121VUADIRS/ADIRU/3/28VDC6FP3N03
4. Procedure
Subtask 34-11-17-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Air Data Module (ADM)
NOTE: ADM 19FP8 has no foam insulation.
   (1) For the removal of ADM 19FP4 or 19FP6:
  • Put the WARNING NOTICE(S) in position to tell persons not to open access door 824.
  • Close access door 824.
   (2) Disconnect the electrical connector (9).
   (3) Disconnect the quick-disconnect coupling (8).
   (4) Put the CAP - BLANKING on the disconnected electrical connectors (6) and (9).
   (5) Put PLUG - BLANKING on the disconnected quick-disconnect couplings (7) and (8).
   (6) Hold the ADM (3) and remove the four screws (5) and the washers (4).
   (7) Remove the ADM (3).
   (8) Remove the foam insulation (2).
Subtask 34-11-17-020-050-D ** ON A/C NOT FOR ALL
A. Removal of the Air Data Module (ADM)
NOTE: ADM 19FP8 has no foam insulation and spacer.
   (1) For the removal of ADM 19FP4 or 19FP6:
  • Put the WARNING NOTICE(S) in position to tell persons not to open access door 824.
  • Close access door 824.
   (2) Disconnect the electrical connector (9).
   (3) Disconnect the quick-disconnect coupling (8).
   (4) Put the CAP - BLANKING on the disconnected electrical connectors (6) and (9).
   (5) Put the PLUG - BLANKING on the disconnected quick-disconnect couplings (7) and (8).
   (6) Hold the ADM (3) and remove the four screws (5) and the washers (4).
   (7) Remove the ADM (3).
   (8) Remove the foam insulation (2) and its four spacers (10).
   (9) Do a general visual inspection of the spacers (10):
     (a) Make sure that there are no signs of damage or cracks on the spacers (10).
     (b) If you find damage, discard the spacers (10).
   (10) Do a check of the dimensions of the spacers (10):
     (a) Make sure that:
       1 The inside diameter of the spacers is 5.00 mm (0.197 in.) plus or minus 0.20 mm (0.008 in.).
       2 The length of the spacers is 7.93 mm (0.312 in.) plus or minus 0.20 mm (0.008 in.).
NOTE: The outside diameter of the spacers is not important for the installation of the ADM.
       3 If the spacers do not have these dimensions, discard the spacers (10).