W DOC AIRBUS | AMM A320F

Reactivation of the Air Data Reference (ADR) 2 or 3 (FAA only)


TASK 34-10-00-440-801-A
Reactivation of the Air Data Reference (ADR) 2 or 3 (FAA only)


ZONE: 210
FIN: 1FP2
FIN: 1FP3
1. Reason for the Job
MMEL 34-10-01
ADR 2 OR 3 (FAA ONLY)
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 34-10-00-861-065-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 34-10-00-865-099-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUADIRS/ADIRU/2/26VAC AND AOA5FP2N08
121VUADIRS/ADIRU/3/26VAC AND AOA5FP3N07
4. Procedure
Subtask 34-10-00-440-050-A
A. Reactivation of the ADR 2 and ADR 3
   (1) Do the step that follows to do the reactivation of the ADR 2:
ACTION
RESULT
1.On circuit breaker panel 121VU:
  • Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
  • 5FP2

2.On center pedestal 11VU, on SWITCHING panel 8VU:
  • Set the AIR DATA selector switch on the NORM position.

3.On overhead panel 20VU, on the ADIRS CDU:
  • Remove the WARNING NOTICE(S).

4.On overhead panel 20VU, on the ADIRS CDU:
  • Push the ADR 2 pushbutton switch.
On overhead panel 20VU, on the ADIRS CDU:
  • The OFF legend of the ADR 2 pushbutton switch goes off.
   (2) Do the step that follows to do the reactivation of the ADR 3:
ACTION
RESULT
1.On circuit breaker 121VU:
  • Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
  • 5FP3

2.On overhead panel 20VU, on the ADIRS CDU:
  • Remove the WARNING NOTICE(S).

3.On overhead panel 20VU, on the ADIRS CDU:
  • Push the ADR 3 pushbutton switch.
On overhead panel 20VU, on the ADIRS CDU:
  • The OFF legend of the ADR 3 pushbutton switch goes off.
5. Close-up
Subtask 34-10-00-942-050-A
A. Put the aircraft back to its initial configuration.
   (1) Remove the entry from the logbook.
Subtask 34-10-00-862-066-A
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:23:00 UTC