W DOC AIRBUS | AMM A320F

ADIRS - Check of all Flight Control Accelerometers for Correct Operation


TASK 34-10-00-040-002-A
ADIRS - Check of all Flight Control Accelerometers for Correct Operation


ZONE: 210
FIN: 12CE1
FIN: 12CE2
FIN: 12CE3
FIN: 12CE4
1. Reason for the Job
MMEL 34-10-01 ADIRS (FAA only).
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 27-96-00-740-001-A
BITE Test of the EFCS (Ground Scanning)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 34-10-00-860-077-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
   (3) On the center pedestal, on the ECAM control panel, push the STS key (on the lower ECAM DU, the STATUS page comes into view).
4. Procedure
Subtask 34-10-00-040-050-A
A. If there is the F/CTL maintenance status:
   (1) Do the BITE test of the EFCS (Ground Scanning) (Ref. AMM TASK 27-96-00-740-001).
   (2) Make sure that there are no maintenance messages related to the flight control accelerometers 12CE1, 12CE2, 12CE3 and 12CE4.
5. Close-up
Subtask 34-10-00-860-078-A
A. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) Make an entry in the logbook.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:23:00 UTC