W DOC AIRBUS | AMM A320F

Installation of the Seat/Wall-Mounted Emergency Light (BRUCE)


TASK 33-51-19-400-002-A
Installation of the Seat/Wall-Mounted Emergency Light (BRUCE)


NOTE: The procedure is the same for all the seat-mounted emergency lights.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
23
O-RING
AIPC 33-51-19-02-030
4
O-RING
AIPC 33-51-19-02-030
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 33-51-00-710-009-A
Check of all the Cabin Lights and Signs for Correct Illumination and Correct Installation
F Seat/Wall-Mounted Emergency Light ** ON A/C NOT FOR ALL
3. Job Set-up
CAUTION: DO NOT USE THE TEACH-IN PROCEDURE TO CLEAR EPSU FAILURE MESSAGES. THE TEACH-IN PROCEDURE IS NOT A SYSTEM RESET. IT CAN CHANGE THE EMERGENCY LIGHT CONFIGURATION AND CAUSE HIDDEN FAILURES.
NOTE: The teach-in procedure of the EPSUs measures and keeps the load values that are related to each EPSU. The EPSU controller refers to these load values when the BITE test of the emergency lighting system operates. Thus, it is necessary that the emergency lights of the related EPSUs operate correctly during the teach-in procedure.
Subtask 33-51-19-860-057-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the EMER EXIT LT switch 4WL on the overhead panel 25VU is in the OFF position.
   (2) Make sure that the LIGHT EMER pushbutton switch and its integral light on the forward attendant panel 120RH are off.
Subtask 33-51-19-865-053-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN2WLH06
49VULIGHTING/EMER LT/CABIN1WLH05
122VULIGHTING/CABIN/EMER/LT3WLV07
4. Procedure
Subtask 33-51-19-910-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
Subtask 33-51-19-420-051-C ** ON A/C NOT FOR ALL
B. Installation of the Seat-Mounted Emergency Light (BRUCE)
WARNING: WHEN YOU INSTALL THE EMERGENCY LIGHT OR THE LIGHT LENS, MAKE SURE THAT IT POINTS TO THE FLOOR. IF IT DOES NOT POINT TO THE FLOOR, THERE IS A RISK THAT, DURING EVACUATION: - THE PASSENGERS WILL GET THE LIGHT IN THEIR EYES - THE PASSENGERS WILL NOT SEE THE EMERGENCY ESCAPE PATH CORRECTLY.
   (1) Installation of the Light Assembly
     (a) Make sure that all the electrical connections are clean and in the correct condition.
     (b) Connect the electrical connector (6) to the electrical connector (7).
     (c) Install the light housing (2) to the passenger seat.
Make sure that you hear a click when the light housing (2) locks in position.
   (2) Installation of the Bulb of the Light
     (a) Put a new AIPC 33-51-19-02-030 O-RING (4) on the lampholder (5).
     (b) Install the bulb (3) in the lampholder (5).
     (c) Push the lampholder (5) into the light housing (2).
     (d) Install the light housing (2) to the passenger seat.
Make sure that you hear a click when the light housing (2) locks in position.
Subtask 33-51-19-420-055-A ** ON A/C NOT FOR ALL Subtask 33-51-19-865-059-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN2WLH06
49VULIGHTING/EMER LT/CABIN1WLH05
122VULIGHTING/CABIN/EMER/LT3WLV07
Subtask 33-51-19-860-055-A ** ON A/C NOT FOR ALL
Subtask 33-51-19-710-051-A ** ON A/C NOT FOR ALL
F. Do the operational test of the cabin emergency lighting (Ref. AMM TASK 33-51-00-710-009).
5. Close-up
Subtask 33-51-19-860-056-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 00:57:36 UTC